added 2026/09/03 2:21 p.m.31 views

CVE-2026-63694

Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command 'Command Injection' vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution...

5CVSS0.01103EPSS
SaveExploits0References1
CVE
CVE
added 2026/09/03 2:21 p.m.9 views

CVE-2026-63694

Dell SmartFabric OS10 Software , versions prior to 10.5.6.14 , contains a Command Injection vulnerability (Improper Neutralization of Special Elements used in a Command). A high-privileged attacker with remote access could potentially exploit this flaw to achieve arbitrary command execution on th...

5CVSS6AI score0.01103EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/03 2:21 p.m.11 views

EUVD-2026-70497

Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command 'Command Injection' vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution...

5CVSS6AI score0.01103EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/03 2:13 p.m.30 views

CVE-2026-35160

Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution...

5CVSS0.01103EPSS
SaveExploits0References1
CVE
CVE
added 2026/09/03 2:13 p.m.11 views

CVE-2026-35160

Dell SmartFabric OS10 Software , versions prior to 10.5.6.14 , contains an OS Command Injection vulnerability (CWE-78). A high-privileged attacker with remote access could potentially exploit this flaw to achieve arbitrary command execution on the device. The CVSS 3.1 score is 5.0 (MEDIUM) with h...

5CVSS6AI score0.01103EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/03 2:13 p.m.10 views

EUVD-2026-70493

Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution...

5CVSS6AI score0.01103EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/03 8:15 a.m.38 views

CVE-2026-68860

Dell PowerProtect Data Manager, versions 20.2.0.0 and below, contain a Reliance on Data/Memory Layout vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to Launch of phishing attacks...

6.8CVSS0.00349EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/03 8:10 a.m.30 views

CVE-2026-74769

Dell PowerProtect Data Manager, versions 20.2.0.0 and below, contain an Incorrect Authorization vulnerability in the REST API. A low privileged remote attacker could potentially exploit this vulnerability, leading to Protection mechanism bypass...

6.5CVSS0.0038EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2026/09/03 12:00 a.m.6 views

Dell iDRAC9 7.0.x < 7.00.00.182 / 7.20.x < 7.20.30.50 Improper Access Control (DSA-2026-374)

The version of Dell Integrated Remote Access Controller 9 iDRAC9 running on the remote host is 7.0.x prior to 7.00.00.182, or 7.20.x prior to 7.20.30.50. It is, therefore, affected by an improper access control vulnerability. A remote attacker with low privileges could potentially exploit this...

5.9CVSS5.7AI score0.00181EPSS
SaveExploits0References2
Kitploit
Kitploit
added 2026/09/02 8:27 p.m.5 views

FakeDellOM

FakeDellOM Un host falso que puede ser "gestionado" por Dell OMSA, permitiéndote superar la pantalla de inicio de sesión, y posiblemente sirviendo como punto de partida para fuzzing u otras pruebas. Historia Mientras investigaba posibles vulnerabilidades¹ en Dell OpenManage Server Administrator, ...

5.9AI score
SaveExploits0
Kitploit
Kitploit
added 2026/09/01 6:08 p.m.6 views

CVE-2021-21551-POC

DbUtilAx Una prueba de concepto extendida para el exploit de kernel Dell ‘dbutil23.sys’ del CVE-2021-21551. Lee el artículo completo aquí...

8.8CVSS7.8AI score0.79249EPSS
SaveExploits18
NVD
NVD
added 2026/09/01 5:17 p.m.12 views

CVE-2026-58566

Dell PowerStore, an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges...

8.8CVSS0.00232EPSS
SaveExploits0References1
Kitploit
Kitploit
added 2026/09/01 5:07 p.m.4 views

cve-2018-1207

cve-2018-1207 Exploit para firmware iDRAC 7 y 8 2.52.52.52 Descripción Dell EMC iDRAC7/iDRAC8, versiones anteriores a 2.52.52.52, contienen una vulnerabilidad de inyección CGI que podría usarse para ejecutar código remoto. Un atacante remoto no autenticado podría potencialmente usar variables CGI...

9.8CVSS8.4AI score0.90091EPSS
SaveExploits3
NVD
NVD
added 2026/09/01 4:17 p.m.8 views

CVE-2026-79687

Dell PowerStore SDNAS contains a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Filesystem access...

9CVSS0.00275EPSS
SaveExploits0References1
NVD
NVD
added 2026/09/01 4:17 p.m.8 views

CVE-2026-79682

Dell PowerStore contains a Command Injection vulnerability. An authenticated user with limited privileges could potentially exploit this vulnerability to execute arbitrary commands with root privileges...

8.8CVSS0.00525EPSS
SaveExploits0References1
NVD
NVD
added 2026/09/01 4:17 p.m.7 views

CVE-2026-58567

Dell PowerStore contains an OS Command Injection vulnerability. An authenticated user with limited privileges could potentially exploit this vulnerability to execute arbitrary commands with root privileges...

8.8CVSS0.00513EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/01 4:08 p.m.8 views

EUVD-2026-69385

Dell PowerStore, an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges...

8.8CVSS5.9AI score0.00232EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/01 4:08 p.m.37 views

CVE-2026-58566

Dell PowerStore, an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges...

8.8CVSS0.00232EPSS
SaveExploits0References1
CVE
CVE
added 2026/09/01 4:08 p.m.23 views

CVE-2026-58566

CVE-2026-58566 is an Incorrect Authorization vulnerability in Dell PowerStore . A low-privileged attacker with remote network access could exploit it to achieve elevation of privileges , with a CVSS 3.1 base score of 8.8 (HIGH) — indicating high impact to confidentiality, integrity, and availabil...

8.8CVSS5.9AI score0.00232EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/01 3:58 p.m.8 views

EUVD-2026-69303

Dell PowerStore SDNAS contains a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Filesystem access...

9CVSS6AI score0.00275EPSS
SaveExploits0References1