Lucene search
+L

4300 matches found

Positive Technologies
Positive Technologies
added 2024/08/01 12:0 a.m.11 views

PT-2024-5761 · Vonets · Vonets Industrial Wifi Bridge Relays +1

Name of the Vulnerable Software and Affected Versions: Vonets Industrial WiFi Bridge Relays and WiFi Bridge Repeaters versions 3.3.23.6.9 and prior Description: The issue exists due to the presence of hard-coded credentials in the application code. This allows a remote attacker to bypass...

9.8CVSS7.8AI score0.00633EPSS
SaveExploits0References10
Gitee
Gitee
added 2024/07/30 1:28 p.m.75 views

Exploit for Server-Side Request Forgery in Adobe Experience_Manager

This repository is an offensive tool for vulnerability exploitation, specifically targeting Adobe AEM Experience Manager vulnerabilities. The primary CVE ID is CVE-2018-12809. The tool is designed to exploit a SSRF Server-Side Request Forgery vulnerability in AEM, allowing an attacker to extract...

7.5CVSS6.7AI score0.04949EPSS
SaveExploits1
Tenable Nessus
Tenable Nessus
added 2024/07/29 12:0 a.m.14 views

Dahua Security Cameras Insecure Storage of Sensitive Information (CVE-2017-7253)

Dahua IP Camera devices 3.200.0001.6 can be exploited via these steps: 1. Use the default low-privilege credentials to list all users via a request to a certain URI. 2. Login to the IP camera with admin credentials so as to obtain full control of the target IP camera. During exploitation, the fir...

9CVSS7.4AI score0.02592EPSS
SaveExploits1References4
NVD
NVD
added 2024/07/26 12:15 p.m.26 views

CVE-2024-41690

This vulnerability exists in SyroTech SY-GPON-1110-WDONT Router due to storing of default username and password credentials in plaintext within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to...

7CVSS0.00152EPSS
SaveExploits0References2
OSV
OSV
added 2024/07/26 12:15 p.m.6 views

CVE-2024-41690

This vulnerability exists in SyroTech SY-GPON-1110-WDONT Router due to storing of default username and password credentials in plaintext within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to...

4.6CVSS5.8AI score0.00152EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/07/26 12:2 p.m.19 views

CVE-2024-41690 Default Credential Storage in Plaintext Vulnerability

This vulnerability exists in SyroTech SY-GPON-1110-WDONT Router due to storing of default username and password credentials in plaintext within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to...

7CVSS7AI score0.00152EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2024/07/26 12:0 a.m.12 views

PT-2024-29511 · Syrotech · Sy-Gpon-1110-Wdont Router

Name of the Vulnerable Software and Affected Versions: SyroTech SY-GPON-1110-WDONT Router affected versions not specified Description: This issue exists due to the storage of default username and password credentials in plaintext within the router's firmware/database. An attacker with physical...

7CVSS6.5AI score0.00152EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2024/07/26 12:0 a.m.10 views

SyroTech SY-GPON-1110-WDONT 安全漏洞

The SyroTech SY-GPON-1110-WDONT is a wireless router from SyroTech. The SyroTech SY-GPON-1110-WDONT suffers from an information disclosure vulnerability that originates from storing default username and password credentials in plaintext in the router firmware/database. An attacker could exploit...

7CVSS6.5AI score0.00152EPSS
SaveExploits0References2
OSV
OSV
added 2024/07/24 4:15 p.m.23 views

CVE-2024-31970

AdTran SRG 834-5 HDC17600021F1 devices with SmartOS 11.1.1.1 and fixed in Version 12.1.3.1 have SSH enabled by default, accessible both over the LAN and the Internet. During a window of time when the device is being set up, it uses a default username and password combination of admin/admin with...

8.8CVSS6.1AI score0.00608EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
added 2024/07/24 12:0 a.m.15 views

CVE-2024-31970

AdTran SRG 834-5 HDC17600021F1 devices with SmartOS 11.1.1.1 and fixed in Version 12.1.3.1 have SSH enabled by default, accessible both over the LAN and the Internet. During a window of time when the device is being set up, it uses a default username and password combination of admin/admin with...

9.2AI score0.00608EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2024/07/24 12:0 a.m.47 views

CVE-2024-31970

AdTran SRG 834-5 HDC17600021F1 devices with SmartOS 11.1.1.1 and fixed in Version 12.1.3.1 have SSH enabled by default, accessible both over the LAN and the Internet. During a window of time when the device is being set up, it uses a default username and password combination of admin/admin with...

0.00608EPSS
SaveExploits0References3
CVE
CVE
added 2024/07/24 12:0 a.m.84 views

CVE-2024-31970

The CVE-2024-31970 entry concerns AdTran SRG 834-5 HDC17600021F1 devices running SmartOS prior to 12.1.3.1. The root cause is hardcoded SSH credentials (admin/admin) used during a setup window, granting root-level privileges and enabling an attacker to modify the admin account or create a new one...

8.8CVSS9.8AI score0.00608EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2024/07/18 5:15 p.m.26 views

CVE-2023-40704

The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity...

9.8CVSS0.00338EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/07/18 4:33 p.m.28 views

CVE-2023-40704 Philips Vue PACS Use of Default Credentials

The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity...

6.8CVSS8.2AI score0.00338EPSS
SaveExploits0References2
CVE
CVE
added 2024/07/18 4:33 p.m.44 views

CVE-2023-40704

Philips Vue PACS is affected by CVE-2023-40704 (Use of Default Credentials) as documented in multiple sources. The issue stems from weak password requirements during installation, allowing default credentials to be used and potentially enabling an attacker to access the PACS database, compromisin...

9.8CVSS7.4AI score0.00338EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2024/07/18 4:33 p.m.35 views

CVE-2023-40704 Philips Vue PACS Use of Default Credentials

The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity...

6.8CVSS0.00338EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2024/07/18 12:0 a.m.7 views

PT-2024-12910 · Philips · Philips Vue Pacs

Name of the Vulnerable Software and Affected Versions: Philips Vue PACS affected versions not specified Description: The issue concerns the use of default credentials for potentially critical functionality in Philips Vue PACS. There is no information provided about the estimated number of...

9.8CVSS6.8AI score0.00338EPSS
SaveExploits0References7
OpenVAS
OpenVAS
added 2024/07/08 12:0 a.m.206 views

Toshiba Printers Multiple Vulnerabilities (May 2024)

Multiple Toshiba printers are prone to multiple vulnerabilities. SPDX-FileCopyrightText: 2024 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

9.8CVSS7.4AI score0.26811EPSS
SaveExploits2References5
Packet Storm
Packet Storm
added 2024/07/04 12:0 a.m.2157 views

Sharp Multi-Function Printer 18 Vulnerabilities

Hello, Please find a text-only version below sent to security mailing lists. The complete version on "17 vulnerabilities in Sharp Multi-Function Printers" is posted here: https://pierrekim.github.io/blog/2024-06-27-sharp-mfp-17-vulnerabilities.html The text version is also posted here:...

9.1CVSS7.1AI score0.45842EPSS
SaveExploits2
Positive Technologies
Positive Technologies
added 2024/07/03 12:0 a.m.16 views

PT-2025-54259

Name of the Vulnerable Software and Affected Versions Ksenia Security Lares 4.0 Home Automation version 1.6 Description Ksenia Security Lares 4.0 Home Automation version 1.6 has a default credentials issue that allows unauthorized access to administrative functions. Successful exploitation grants...

10CVSS6.7AI score0.0054EPSS
SaveExploits2References11
Rows per page
Query Builder