4330 matches found
CVE-2020-21999
iWT Ltd FaceSentry Access Control System 6.4.8 suffers from an authenticated OS command injection vulnerability using default credentials. This can be exploited to inject and execute arbitrary shell commands as the root user via the 'strInIP' POST parameter in pingTest PHP script...
Command injection
iWT Ltd FaceSentry Access Control System 6.4.8 suffers from an authenticated OS command injection vulnerability using default credentials. This can be exploited to inject and execute arbitrary shell commands as the root user via the 'strInIP' POST parameter in pingTest PHP script...
CVE-2020-21999
CVE-2020-21999 affects iWT FaceSentry Access Control System (Firmware 6.4.8, 5.7.x) where an authenticated OS command injection is possible via the strInIP POST parameter in pingTest.php. The vulnerability uses default credentials and executes sudo ping with user-supplied input, enabling arbitrar...
CVE-2020-21999
iWT Ltd FaceSentry Access Control System 6.4.8 suffers from an authenticated OS command injection vulnerability using default credentials. This can be exploited to inject and execute arbitrary shell commands as the root user via the 'strInIP' POST parameter in pingTest PHP script...
CVE-2020-21992
Inim Electronics SmartLiving SmartLAN/G/SI =6.x suffers from an authenticated remote command injection vulnerability. The issue exist due to the 'par' POST parameter not being sanitized when called with the 'testemail' module through web.cgi binary. The vulnerable CGI binary ELF 32-bit LSB...
CVE-2020-21995
Inim Electronics Smartliving SmartLAN/G/SI =6.x uses default hardcoded credentials. An attacker could exploit this to gain Telnet, SSH and FTP access to the system...
CVE-2020-21992
Inim Electronics SmartLiving SmartLAN/G/SI =6.x suffers from an authenticated remote command injection vulnerability. The issue exist due to the 'par' POST parameter not being sanitized when called with the 'testemail' module through web.cgi binary. The vulnerable CGI binary ELF 32-bit LSB...
CVE-2020-21995
Inim Electronics Smartliving SmartLAN/G/SI =6.x uses default hardcoded credentials. An attacker could exploit this to gain Telnet, SSH and FTP access to the system...
Command injection
Inim Electronics SmartLiving SmartLAN/G/SI =6.x suffers from an authenticated remote command injection vulnerability. The issue exist due to the 'par' POST parameter not being sanitized when called with the 'testemail' module through web.cgi binary. The vulnerable CGI binary ELF 32-bit LSB...
CVE-2020-21995
CVE-2020-21995 affects INIM Electronics SmartLiving SmartLAN/G/SI devices (affected <= 6.x). Root cause is hard-coded credentials embedded in the Linux distribution image, enabling an attacker to access Telnet, SSH, and FTP. Affected models include SmartLiving 505, 515, 1050/1050/G3, 10100L/10...
CVE-2020-21995
Inim Electronics Smartliving SmartLAN/G/SI =6.x uses default hardcoded credentials. An attacker could exploit this to gain Telnet, SSH and FTP access to the system...
CVE-2020-21992
Inim Electronics SmartLiving SmartLAN/G/SI =6.x suffers from an authenticated remote command injection vulnerability. The issue exist due to the 'par' POST parameter not being sanitized when called with the 'testemail' module through web.cgi binary. The vulnerable CGI binary ELF 32-bit LSB...
INIM ELECTRONICS SmartLiving System 信任管理问题漏洞
INIM ELECTRONICS SmartLiving System is an application of the Italian company INIM ELECTRONICS. A SmartLiving System. A security vulnerability exists in INIM ELECTRONICS SmartLiving System that stems from the use of default hard-coded credentials...
INIM ELECTRONICS SmartLiving System 操作系统命令注入漏洞
INIM ELECTRONICS SmartLiving System is an application of the Italian company INIM ELECTRONICS. A SmartLiving System. Inim Electronics SmartLiving SmartLAN/G/SI = 6.x An operating system command injection vulnerability can be exploited to allow an attacker to remotely execute system commands using...
Hardcoded credentials
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices...
Default credentials
Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system...
Default credentials
Gestsup before 3.2.10 allows account takeover through the password recovery functionality remote. The affected component is the file forgotpwd.php - it uses a weak algorithm for the generation of password recovery tokens the PHP uniqueid function, allowing a brute force attack...
Default credentials
OrangeHRM 4.7 allows an unauthenticated user to enumerate the valid username and email address via the forgot password function...
Default credentials
A vulnerability has been identified in Tecnomatix RobotExpert All versions V16.1. Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this...
Default credentials
A vulnerability has been identified in Solid Edge SE2020 All versions SE2020MP13, Solid Edge SE2020 All versions SE2020MP14, Solid Edge SE2021 All Versions SE2021MP4. Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds...