4872 matches found
CVE-2025-40585
A vulnerability has been identified in Energy Services All versions with G5DFR. Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device...
CVE-2025-40585
A vulnerability has been identified in Energy Services All versions with G5DFR. Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device...
CVE-2025-40585
Summary: CVE-2025-40585 affects Siemens Energy Services for all versions using the G5DFR component, where default credentials enable an attacker to gain control of G5DFR and tamper with device outputs. What’s affected: Energy Services with G5DFR (default credentials exist). Cause: Use of default ...
PT-2025-24678 · Unknown · Energy Services
Name of the Vulnerable Software and Affected Versions: Energy Services versions with G5DFR Description: A vulnerability has been identified in Energy Services where affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of the G5DFR component and...
Siemens Energy Services 安全漏洞
Siemens Energy Services is an energy management system from Siemens Canada. A security vulnerability exists in Siemens Energy Services that stems from the G5DFR component containing default credentials that could lead to controlling the G5DFR component and tampering with device output...
📄 INDAMED - MEDICAL OFFICE Demo Version Privilege Escalation / Default Credentials
INDAMED - MEDICAL OFFICE demo version revision 18544 II/20224 suffers from local privilege escalation and default credential vulnerabilities. SEC Consult Vulnerability Lab Security Advisory ======================================================================= title: Local Privilege Escalation a...
CVE-2025-40585: Incorrect Default Permissions
A vulnerability has been identified in Energy Services All versions with G5DFR. Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device...
VulnCheck KEV: CVE-2025-26793
The Web GUI configuration panel of Hirsch formerly Identiv and Viscount Enterphone MESH through 2024 ships with default credentials username freedom, password viscount. The administrator is not prompted to change these credentials on initial configuration, and changing the credentials requires ma...
CVE-2024-40113
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials...
CVE-2024-40113
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials...
CVE-2024-40113
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials...
Sitecom WLX-2006 Wall Mount Range Extender N300 安全漏洞
The Sitecom WLX-2006 Wall Mount Range Extender N300 is a wall mount range extender from Sitecom. A security vulnerability exists in the Sitecom WLX-2006 Wall Mount Range Extender N300 v1.5 and earlier versions that stems from the use of default credentials...
CVE-2024-40113
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials...
CVE-2024-40113
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials...
CVE-2024-40113
The Sitecom WLX-2006 Wall Mount Range Extender N300 (v.1.5 and earlier) is vulnerable to the Use of Default Credentials (CWE-1392). This security flaw allows unauthorized access to the device. To mitigate this risk, users are recommended to change default credentials to unique and strong password...
CVE-2024-40113: Use of Default Credentials
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials...
PT-2025-23524 · Sitecom · Sitecom Wlx-2006
Name of the Vulnerable Software and Affected Versions: Sitecom WLX-2006 Wall Mount Range Extender N300 versions 1.5 and earlier Description: The issue concerns the use of default credentials in the Sitecom WLX-2006 Wall Mount Range Extender N300. This allows unauthorized access to the device. No...
CVE-2025-4633
Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal...
CVE-2025-4633
Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal...
CVE-2025-4633
CVE-2025-4633 concerns Airpointer 2.4.107-2 where default credentials in the web portal allow an unauthenticated attacker to log in. Affected component: the web portal of Airpointer 2.4.107-2; root cause is default credentials enabling access without authentication. Impact notes from sources indi...