Lucene search
K

9 matches found

NVD
NVD
added 2026/05/14 5:16 p.m.8 views

CVE-2025-62310

HCL AION is affected by a vulnerability where encryption is not enforced for certain data transmissions or operations. This may expose sensitive information to potential interception or unauthorized access under specific conditions...

5.4CVSS0.00007EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2018-16635

Malware in sbrugna...

7.4CVSS7.5AI score0.00104EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2018-16943

Malware in sbrugna...

7.5CVSS8.6AI score0.00587EPSS
Exploits0References17
EUVD
EUVD
added 2025/10/03 8:7 p.m.1 views

EUVD-2024-36214

Malicious code in bioql PyPI...

5.9CVSS6.6AI score0.00088EPSS
Exploits1References1
F5 Networks
F5 Networks
added 2025/08/13 1:5 p.m.6 views

K000152049: F5 Access for Android vulnerability CVE-2025-54809

Security Advisory Description F5 Access for Android before version 3.1.2, which uses HTTPS, does not verify the remote endpoint identity. CVE-2025-54809 Impact An attacker with a network position that allows them to intercept network traffic may be able to read and/or modify data in transit. The...

8.8CVSS6.7AI score0.0008EPSS
Exploits0Affected Software1
NVD
NVD
added 2025/07/22 10:15 p.m.3 views

CVE-2025-53703

DuraComm SPM-500 DP-10iN-100-MU transmits sensitive data without encryption over a channel that could be intercepted by attackers...

8.7CVSS0.00092EPSS
Exploits0References2
OSV
OSV
added 2025/05/01 6:15 p.m.0 views

CVE-2025-32886

An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. All packets sent over RF are also sent over UART with USB Shell, allowing someone with local access to gain information about the protocol and intercept sensitive data...

5.5CVSS5.8AI score
Exploits0References2
RedhatCVE
RedhatCVE
added 2025/02/05 3:12 p.m.6 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS6.9AI score0.00085EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2023/02/01 12:0 a.m.2 views

PT-2023-18851 · Selfwealth · Selfwealth Ios Mobile App

Name of the Vulnerable Software and Affected Versions: Selfwealth iOS mobile App version 3.3.1 Description: The issue concerns Insecure App Transport Security ATS Settings in the Selfwealth iOS mobile App. This means the app may not properly secure its communication, potentially allowing for...

7.5CVSS7.2AI score0.00265EPSS
Exploits0References4
Rows per page
Query Builder