Lucene search
+L

31 matches found

prion
prion
added 2020/01/06 8:15 p.m.14 views

Design/Logic Flaw

On DTEN D5 and D7 before 1.3.4 devices, factory settings allows for firmware reflash and Android Debug Bridge adb enablement...

7.5CVSS9.1AI score0.01162EPSS
Exploits0References1Affected Software2
cve
cve
added 2020/01/06 8:2 p.m.113 views

CVE-2019-16271

DTEN D5 and D7 devices (pre-1.3.2) expose an unauthenticated web server on TCP port 8080 that allows remote attackers to read stored whiteboard PDF images via storage/emulated/0/Notes/PDF. The root cause is lack of authentication on the web interface, enabling direct file disclosure of sensitive ...

5.3CVSS5.3AI score0.01589EPSS
Exploits0References1Affected Software1
cvelist
cvelist
added 2020/01/06 8:2 p.m.15 views

CVE-2019-16271

DTEN D5 and D7 before 1.3.2 devices allows remote attackers to read saved whiteboard image PDF documents via storage/emulated/0/Notes/PDF on TCP port 8080 without authentication...

5.4AI score0.01589EPSS
Exploits0References1
cve
cve
added 2020/01/06 7:58 p.m.83 views

CVE-2019-16272

DTEN D5 and DTEN D7 devices running firmware earlier than 1.3.4 expose a vulnerability where factory settings enable firmware reflashing and Android Debug Bridge (ADB) access. This can lead to full device control and potential exposure of sensitive data (e.g., meeting contents) via exposed admini...

9.8CVSS9.2AI score0.01162EPSS
Exploits0References1Affected Software1
cvelist
cvelist
added 2020/01/06 7:58 p.m.27 views

CVE-2019-16272

On DTEN D5 and D7 before 1.3.4 devices, factory settings allows for firmware reflash and Android Debug Bridge adb enablement...

9.4AI score0.01162EPSS
Exploits0References1
cve
cve
added 2020/01/06 7:55 p.m.98 views

CVE-2019-16273

DTEN D5/D7 devices pre-1.3.4 are vulnerable to unauthenticated root shell access via Android Debug Bridge (ADB), enabling arbitrary code execution and system administration. The issue also enables a covert ability to capture Windows Zoom Client data by executing commands on the Android OS. Affect...

10CVSS9.6AI score0.02327EPSS
Exploits0References1Affected Software1
cvelist
cvelist
added 2020/01/06 7:52 p.m.25 views

CVE-2019-16274

DTEN D5 before 1.3 and D7 before 1.3 devices transfer customer data files via unencrypted HTTP...

7.7AI score0.00674EPSS
Exploits0References1
cve
cve
added 2020/01/06 7:52 p.m.89 views

CVE-2019-16274

DTEN DT5/D7 devices (before firmware 1.3) expose customer data by transferring files over unencrypted HTTP. Concrete details across multiple sources confirm the affected products and version bounds, with the underlying issue described as unencrypted HTTP data transfer that can lead to exposure of...

7.5CVSS7.6AI score0.00674EPSS
Exploits0References1Affected Software1
cnvd
cnvd
added 2019/10/10 12:0 a.m.3 views

Juniper Networks Junos OS License Issue Vulnerability (CNVD-2020-13540)

Juniper Networks Junos OS is a Juniper Networks network operating system for the company's hardware devices. The OS provides a secure programming interface and the Junos SDK. An authorization issue vulnerability exists in Juniper Networks Junos OS versions prior to 18.2R1 and prior to 18.2X75-D5,...

7.8CVSS6.9AI score0.00379EPSS
Exploits0References1
symantec
symantec
added 2019/10/09 12:0 a.m.34 views

Juniper Junos CVE-2019-0057 Local Authorization Bypass Vulnerability

Description Juniper Junos is prone to a local authorization-bypass vulnerability. Attackers can exploit this issue to bypass certain security restrictions and perform unauthorized actions. Versions prior to Junos OS 18.2R1, and 18.2X75-D5 are vulnerable. Technologies Affected Juniper Junos 18.2...

1.7AI score0.00379EPSS
Exploits0References1Affected Software1
nessus
nessus
added 2019/05/08 12:0 a.m.14 views

Rockwell Automation 871TM Unshielded 30mm with micro 871TM-D15ED30-D5 Inductive Proximity Sensor

Binary data 752381.prm...

7.3AI score
Exploits0References1
Rows per page