Lucene search
K

6 matches found

Check Point Advisories
Check Point Advisories
added 2015/02/15 12:0 a.m.1 views

Schneider Electric ProClima MetaDraw ArrangeObjects Memory Corruption (CVE-2014-9188)

A code execution vulnerability has been reported in Schneider Electric ProClima. The vulnerability is due to the dereferencing of an attacker supplied memory address by the MetaDraw ActiveX control's ArrangeObjects method. A remote unauthenticated attacker could exploit this vulnerability by...

9CVSS7AI score0.06121EPSS
Exploits0
NVD
NVD
added 2014/12/27 3:59 p.m.18 views

CVE-2014-9188

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided b...

10CVSS7.7AI score0.06121EPSS
Exploits0References3
Prion
Prion
added 2014/12/27 3:59 p.m.25 views

Buffer overflow

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...

7.5CVSS8.2AI score0.06121EPSS
Exploits0References2Affected Software1
Prion
Prion
added 2014/12/27 3:59 p.m.23 views

Buffer overflow

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...

7.5CVSS8.2AI score0.06121EPSS
Exploits0References3Affected Software1
CVE
CVE
added 2014/12/27 3:0 p.m.66 views

CVE-2014-9188

CVE-2014-9188 is a remote code execution vulnerability in Schneider Electric ProClima's MetaDraw ActiveX control (MDraw30.ocx) prior to version 6.1.7. The issue arises from a buffer overflow in the ActiveX control, with linked advisories detailing additional MetaDraw flaws (ArrangeObjects, ObjLin...

10CVSS7.9AI score0.06121EPSS
Exploits0References3Affected Software1
ICS
ICS
added 2014/09/18 6:0 a.m.66 views

Schneider Electric ProClima Command Injection Vulnerabilities

OVERVIEW NCCIC/ICS-CERT received a report from HP’s Zero Day Initiative ZDI concerning command injection vulnerabilities in Schneider Electric’s ProClima software package. These vulnerabilities were reported to ZDI by security researchers Ariele Caltabiano, Andrea Micalizzi, and Brian Gorenc...

10CVSS7.7AI score0.04436EPSS
Exploits0References10
Rows per page
Query Builder