6 matches found
Procyon Core Server HMI Memory Corruption SCADA Remote Code Execution - Ver2 (CVE-2011-3322)
A remote stack overflow vulnerability has been reported in Procyon Core Server HMI service. The vulnerability is due to a boundary check error. A remote attacker may exploit this issue by sending specially crafted messages to the target server. Successful exploitation could allow an attacker to...
CVE-2011-3322
Core Server HMI Service Coreservice.exe in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service crash and possibly execute arbitrary code via a long password to the Telnet TCP/23 port, which triggers an out-of-bounds read or...
CVE-2011-3322
CVE-2011-3322 affects Procyon Core Server HMI's Coreservice.exe in Scadatec Limited Procyon SCADA 1.06 and other versions before 1.14. The root cause is a boundary check error that, when processing a password sent to Telnet (TCP/23), can trigger an out-of-bounds read/write on the stack, leading t...
Procyon Core Server HMI Coreservice.exe Stack Buffer Overflow
This module exploits a vulnerability in the coreservice.exe component of Proycon Core Server "Procyon Core Server HMI Coreservice.exe Stack Buffer Overflow", 'Description' = %q This module exploits a vulnerability in the coreservice.exe component of Proycon Core Server MSF...
CVE-2011-3322
creationtimestamp| type| source ---|---|--- 2011-09-12 00:00:00+00:00| confirmed| https://www.exploit-db.com/exploits/17827 2018-05-29 15:50:33+00:00| seen| https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/windows/scada/procyoncoreserver.rb 2025-02-06 03:13:40+00:00|...
Scadatec Limited Procyon Telnet Buffer Overflow
Overview ICS-CERT originally released Advisory ICSA-11-216-01P on the US-CERT Portal on August 04, 2011. This web page release was delayed to allow users sufficient time to download and install the update. ICS-CERT has received a report from Knud Højgaard of the nSense Vulnerability Coordination...