Lucene search
+L

8 matches found

Kitploit
Kitploit
•added 2026/10/10 12:41 p.m.•18 views

CVE-2018-7844

CVE-2018-7844 受影响产品 Schneider Electric Modicon M580 所有版本 Schneider Electric Modicon M340 所有版本 Schneider Electric Modicon Premium 所有版本 Schneider Electric Modicon Quantum 所有版本 参考 https://www.se.com/ww/en/download/document/SEVD-2019-134-11/...

7.5CVSS7.7AI score0.03279EPSS
SaveExploits1
RedhatCVE
RedhatCVE
•added 2025/05/22 4:00 a.m.•24 views

CVE-2018-7844

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus...

7.5CVSS6.4AI score0.03279EPSS
SaveExploits1References1
Circl
Circl
•added 2025/04/24 10:00 a.m.•23 views

CVE-2018-7844

creationtimestamp| type| source ---|---|--- 2025-04-24 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-114-01...

7.5CVSS6.8AI score0.03279EPSS
SaveExploits1References1
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•23 views

Schneider Electric Modicon Controllers Exposure of Sensitive Information to an Unauthorized Actor (CVE-2018-7844)

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. This plugin only works with Tenable.ot...

9.8CVSS6.8AI score0.35039EPSS
SaveExploits18References4
Check Point Advisories
Check Point Advisories
•added 2019/07/07 12:00 a.m.•78 views

Schneider Electric Modicon Multiple Information Disclosure Vulnerabilities (CVE-2018-7844; CVE-2018-7845; CVE-2019-6806)

Multiple information disclosure vulnerabilities exist in Schneider Electric Modicon. Successful exploitation of those vulnerabilities would allow a remote attacker to obtain sensitive information...

5CVSS2.6AI score0.03413EPSS
SaveExploits3
NVD
NVD
•added 2019/05/22 9:29 p.m.•28 views

CVE-2018-7844

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus...

7.5CVSS7.3AI score0.03279EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2019/05/22 8:06 p.m.•43 views

CVE-2018-7844

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus...

7.3AI score0.03279EPSS
SaveExploits1References2
CVE
CVE
•added 2019/05/22 8:06 p.m.•110 views

CVE-2018-7844

CVE-2018-7844 affects Schneider Electric Modicon M580, M340, Quantum and Premium PLCs. The UMAS read memory block function can disclose plaintext data, including SNMP community strings, when reading memory blocks over Modbus. Exploitation is unauthenticated and feasible against firmware versions ...

7.5CVSS7.2AI score0.03279EPSS
SaveExploits1References2Affected Software1
Rows per page
Query Builder