6907 matches found
CVE-2026-63355
Affected devices are vulnerable to Cross-Site Scripting (XSS) because they do not properly sanitize signal names within imported CSV trace files before rendering them in selection menus on the Trace page. An attacker could social engineer an authorized user with "Read diagnostics" rights into imp...
CVE-2026-63354
Affected devices fail to properly validate and sanitize visual marker data within imported CSV trace files before rendering it on the Trace page . This vulnerability allows an attacker to use social engineering to trick an authorized user with "Read diagnostics" rights into importing a malicious ...
CVE-2026-63354
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially...
CVE-2026-63352
Affected devices fail to properly sanitize calculated signal data from imported CSV trace files before rendering it on the Trace page . This vulnerability allows an attacker to perform a social engineering attack to trick an authorized user with "Read diagnostics" rights into importing a maliciou...
CVE-2026-63352
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace...
CVE-2026-63351
Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into...
CVE-2026-63351
Affected devices fail to properly validate and sanitize visual properties of calculated signals within imported CSV trace files before rendering them on the Trace page. This vulnerability allows an attacker to use social engineering to trick an authorized user with "Read diagnostics" rights into ...
PT-2026-111382
Name of the Vulnerable Software and Affected Versions Schneider Electric Modicon PLC affected versions not specified Description Devices fail to properly sanitize calculated signal data within imported CSV trace files before displaying it on the Trace page. An attacker could trick an authorized...
PT-2026-111385
Name of the Vulnerable Software and Affected Versions Siematic S7 affected versions not specified Description Devices fail to properly sanitize signal names within imported CSV trace files before they are rendered in selection menus on the Trace page. This flaw allows an attacker to trick an...
CVE-2026-63352: Improper Neutralization of Input During Web Page Generation
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace...
CVE-2026-63356: Improper Neutralization of Input During Web Page Generation
Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a...
CVE-2026-63355: Improper Neutralization of Input During Web Page Generation
Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in selection menus on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially...
CVE-2026-63354: Improper Neutralization of Input During Web Page Generation
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially...
CVE-2026-63351: Improper Neutralization of Input During Web Page Generation
Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into...
PT-2026-111381
Name of the Vulnerable Software and Affected Versions Siematic S7-1500 affected versions not specified Description Devices fail to properly validate and sanitize visual properties of calculated signals within imported CSV trace files before they are rendered on the Trace page. An attacker could u...
PT-2026-111384
Name of the Vulnerable Software and Affected Versions Siemens S7-1500 affected versions not specified Description Devices fail to properly validate and sanitize visual marker data within imported CSV trace files before rendering the information on the Trace page. An attacker could social engineer...
PT-2026-111386
Name of the Vulnerable Software and Affected Versions The product name cannot be determined affected versions not specified Description Improper sanitization of calculated signal names within imported CSV trace files allows for Cross-Site Scripting XSS on the Trace page. An attacker can social...
CVE-2026-109396
Thelia before 3.1.2 and 3.2.x before 3.2.1 contains a CSV formula injection vulnerability that allows unauthenticated visitors to inject spreadsheet formulas by supplying crafted registration, checkout or newsletter fields. Attackers can submit names, addresses or phone values starting with =, +,...
CVE-2026-109396
The Thelia platform (versions before 3.1.2 and 3.2.x before 3.2.1 ) is vulnerable to a CSV formula injection vulnerability. The issue resides in the CSVSerializer component, which exports fields like registration, checkout, or newsletter data verbatim. Unauthenticated visitors can exploit this by...
EUVD-2026-97493
Thelia before 3.1.2 and 3.2.x before 3.2.1 contains a CSV formula injection vulnerability that allows unauthenticated visitors to inject spreadsheet formulas by supplying crafted registration, checkout or newsletter fields. Attackers can submit names, addresses or phone values starting with =, +,...