11831 matches found
CVE-2022-23507
The CVE concerns Tendermint’s light-client verification prior to version 0.28.0, where the light client does not verify that the trusted and untrusted chain IDs match during header verification. This can allow a header from an untrusted chain that passes other checks (e.g., overlapping validator ...
CVE-2022-2660
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine...
Hardcoded credentials
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine...
CVE-2022-2660
CVE-2022-2660 affects Delta Electronics DIALink (Industrial Automation server) v1.4.0.0 and earlier. The vulnerability stems from the use of a hard-coded cryptographic key, which could allow an attacker to decrypt sensitive data and compromise the machine. Impact is high/critical depending on met...
CVE-2022-2660
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine...
CVE-2022-2660
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine...
CVE-2022-46834
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-46833
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-46834
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
Design/Logic Flaw
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
Design/Logic Flaw
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
Design/Logic Flaw
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version 2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmwa...
CVE-2022-46832
CVE-2022-46832 affects SICK RFU62x firmware pre-2.21. The issue arises when a user requests encryption with a weak cipher suite via SSH, enabling a low-privilege remote attacker to decrypt data due to use of a broken/risky cryptographic algorithm. A patch/update to version 2.21 or later is availa...
CVE-2022-46832
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version 2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmwa...
CVE-2022-46834
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-46833
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
Siemens SCALANCE Products
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2022-27581
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU61x firmware version v2.25 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-46834
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...
CVE-2022-46833
The CVE-2022-46833 entry describes a vulnerability in SICK RFU63x firmware prior to version 2.21 where requesting weak cipher suites via SSH enables a low-privileged remote attacker to decrypt data due to use of a broken/risky cryptographic algorithm. Impact is confidentiality loss (C:H) with net...