Lucene search
+L

109 matches found

OSV
OSV
•added 2022/04/04 8:15 p.m.•16 views

CVE-2021-32980

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS5.8AI score0.01113EPSS
SaveExploits0References1
NVD
NVD
•added 2022/04/04 8:15 p.m.•65 views

CVE-2021-32978

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...

7.5CVSS0.0101EPSS
SaveExploits0References1
NVD
NVD
•added 2022/04/04 8:15 p.m.•37 views

CVE-2021-32980

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS0.01113EPSS
SaveExploits0References1
Prion
Prion
•added 2022/04/04 8:15 p.m.•26 views

Design/Logic Flaw

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...

5CVSS7.9AI score0.0101EPSS
SaveExploits0References1Affected Software20
Prion
Prion
•added 2022/04/04 8:15 p.m.•25 views

Authentication flaw

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

7.5CVSS9.4AI score0.01113EPSS
SaveExploits0References1Affected Software20
Prion
Prion
•added 2022/04/04 8:15 p.m.•28 views

Buffer overflow

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange...

5CVSS8.1AI score0.00651EPSS
SaveExploits0References1Affected Software20
Prion
Prion
•added 2022/04/04 8:15 p.m.•28 views

Authorization

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...

7.5CVSS9.2AI score0.01113EPSS
SaveExploits0References1Affected Software20
CVE
CVE
•added 2022/04/04 7:45 p.m.•129 views

CVE-2021-32986

The CVE affects Automation Direct CLICK PLC CPU Modules (C0-1x CPUs) with firmware prior to v3.00. The vulnerability is an authentication bypass where, once an authorized user unlocks the PLC, the unlocked state does not timeout and remains usable if the programming software is interrupted; all s...

9.8CVSS9.5AI score0.01113EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2022/04/04 7:45 p.m.•80 views

CVE-2021-32978

The CVE-2021-32978 entry describes a vulnerability in Automation Direct CLICK PLC CPU Modules (C0-1x) with firmware prior to v3.00 where a previously entered password and lock state can be read from the programming protocol, effectively exposing credentials and enabling unlocks if the password wa...

7.5CVSS7.6AI score0.0101EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2022/04/04 7:45 p.m.•11 views

CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS6.9AI score0.01113EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2022/04/04 7:45 p.m.•38 views

CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS9.6AI score0.01113EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•14 views

PT-2022-10178 · Automationdirect · Automation Direct Click Plc Cpu Modules

Name of the Vulnerable Software and Affected Versions: Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description: The issue arises when an authorized user unlocks the Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. The unlocked state...

9.8CVSS9.2AI score0.01113EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•3 views

PT-2022-10175

Name of the Vulnerable Software and Affected Versions Automation Direct CLICK PLC CPU Modules versions prior to v3.00 Description The issue concerns the transmission of passwords in plaintext during unlocking and project transfers for Automation Direct CLICK PLC CPU Modules. An attacker with...

7.5CVSS5.8AI score0.00651EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•2 views

PT-2022-10176

Name of the Vulnerable Software and Affected Versions Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description The issue allows an attacker to connect to the PLC and read the project without authorization during the time it is unlocked by an authorized user, resulti...

9.8CVSS5.8AI score0.01113EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•1 views

PT-2022-10172

Name of the Vulnerable Software and Affected Versions Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was...

7.5CVSS5.7AI score0.0101EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•7 views

CVE-2021-32982: Cleartext Transmission of Sensitive Information

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange...

7.5CVSS7.2AI score0.00651EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•6 views

CVE-2021-32986: Authentication Bypass Using an Alternate Path or Channel

After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without...

9.8CVSS8.2AI score0.01113EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•8 views

CVE-2021-32984: Authentication Bypass Using an Alternate Path or Channel

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...

9.8CVSS8.2AI score0.01113EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•6 views

CVE-2021-32978: Plaintext Storage of a Password

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...

7.5CVSS7.2AI score0.0101EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•4 views

CVE-2021-32980: Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS8.2AI score0.01113EPSS
SaveExploits0References3
Rows per page
Query Builder