Lucene search
+L

2956 matches found

NVD
NVD
added 2021/09/02 5:15 p.m.32 views

CVE-2021-22792

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BMEP and BMEH, all versions, Modicon M340 CPU par...

7.5CVSS0.00937EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2021/09/02 5:15 p.m.6 views

CVE-2021-22789

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BM...

6.5CVSS6.8AI score0.00839EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:00 a.m.13 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium lies in insufficient testing for unusual or exceptional states. This allows a intruder to trigger malfunctions during maintenance.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium lies in insufficient testing for unusual or exceptional states. Exploiting this vulnerability can allow an attacker operati...

7.8CVSS7.2AI score0.01382EPSS
SaveExploits0References2Affected Software2
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:00 a.m.12 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the absence of authentication for a critical function, allowing attackers to execute arbitrary commands.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the absence of authentication for critical functions. Exploiting this vulnerability allows an attacker operating remotely to...

8.5CVSS8AI score0.0222EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2021/09/01 12:00 a.m.14 views

Aruba Networks Aruba Operating System 命令注入漏洞

Aruba Networks Aruba Operating System, the operating system for Aruba controller-managed wireless LANs and Aruba mobile controllers from Aruba Networks, is vulnerable to a command injection vulnerability. The vulnerability is caused by a failure to properly filter special characters, commands, et...

9CVSS6AI score0.03055EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2021/09/01 12:00 a.m.12 views

Aruba Operating System 跨站请求伪造漏洞

Aruba Operating System is the operating system for Aruba controller-managed wireless LANs and Aruba mobile controllers from Aruba Networks, Inc. user interface to perform file deletion operations...

8.8CVSS5.6AI score0.00398EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2021/09/01 12:00 a.m.10 views

Moxa多款产品跨站脚本漏洞

The Moxa WAC-1001 is a series of railroad wireless controllers from Moxa in China. Moxa suffers from a cross-site scripting vulnerability that stems from a security flaw that is present in many Moxa devices...

6.1CVSS6.8AI score0.00937EPSS
SaveExploits3References4
RedHat Linux
RedHat Linux
added 2021/08/31 7:48 p.m.9 views

kernel: race condition for removal of the HCI controller

A flaw was found in the Linux kernel’s handling of the removal of Bluetooth HCI controllers. This flaw allows an attacker with a local account to exploit a race condition, leading to corrupted memory and possible privilege escalation. The highest threat from this vulnerability is to...

7CVSS6.7AI score0.00691EPSS
SaveExploits1References4
RedHat Linux
RedHat Linux
added 2021/08/31 9:18 a.m.8 views

kernel: race condition for removal of the HCI controller

A flaw was found in the Linux kernel’s handling of the removal of Bluetooth HCI controllers. This flaw allows an attacker with a local account to exploit a race condition, leading to corrupted memory and possible privilege escalation. The highest threat from this vulnerability is to...

7CVSS6.7AI score0.00691EPSS
SaveExploits1References4
BDU FSTEC
BDU FSTEC
added 2021/08/31 12:00 a.m.10 views

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, stems from insufficiently secure data encryption. This allows attackers to obtain the encryption key.

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, is related to insufficiently secure data encryption. Exploiting this vulnerability could allow a malicious actor to obtain the encryption key remotely...

7.8CVSS7.1AI score0.00296EPSS
SaveExploits0References2
ICS
ICS
added 2021/08/31 12:00 a.m.95 views

FANUC Robot Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely Vendor: FANUC Equipment: R-30iA and R-30iB series controllers Vulnerabilities: Integer Coercion Error, Out-of-bounds Write 2. UPDATE INFORMATION This advisory is a follow-up to the original advisory titled ICSA-21-243-02P FANUC...

8.8CVSS8.6AI score0.01183EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2021/08/30 12:00 a.m.14 views

The vulnerability of microprogrammed programmable logic controllers like Modicon and PacDrive lies in the lack of authentication for a critical function. This allows attackers to alter the device’s IP configuration.

The vulnerability of the microprogrammed logic controllers Modicon and PacDrive lies in the absence of authentication for the critical function. Exploiting this vulnerability allows an attacker to remotely alter the device’s IP configuration...

7.1CVSS7.5AI score0.0125EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/27 12:00 a.m.12 views

The vulnerability of the communication interface for Smartlink modular equipment, the microprogrammed wireless energy sensor PowerTag, and Wiser controllers, related to the use of insufficiently random values, allows intruders to gain increased privileges.

The vulnerability of the communication interface for Smartlink module equipment, the microprogrammed wireless energy sensor PowerTag, and Wiser controllers is related to the use of insufficiently random values. Exploiting this vulnerability could allow a remote attacker to exploit the system...

7.1CVSS7.8AI score0.01444EPSS
SaveExploits0References3Affected Software6
BDU FSTEC
BDU FSTEC
added 2021/08/26 12:00 a.m.11 views

The vulnerability of microprogrammed software for Modicon M218, M218, M241, M251, and M258 logic controllers lies in insufficient data authenticity checking, allowing attackers to execute arbitrary codes.

The vulnerability of microprogrammed software in Modicon M218, M218, M241, M251, and M258 logic controllers is related to insufficient verification of data authenticity. Exploiting this vulnerability can allow an attacker operating remotely to execute arbitrary codes...

5.4CVSS8.1AI score0.00675EPSS
SaveExploits0References2Affected Software4
The Hacker News
The Hacker News
added 2021/08/25 1:00 p.m.30 views

Researchers Uncover FIN8's New Backdoor Targeting Financial Institutions

A financially motivated threat actor notorious for setting its sights on retail, hospitality, and entertainment industries has been observed deploying a completely new backdoor on infected systems, indicating the operators are continuously retooling their malware arsenal to avoid detection and st...

1.1AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2021/08/25 12:00 a.m.11 views

The vulnerability of the Modbus protocol implementation in microprogrammed software for programmable logic controllers like Modicon Quantum allows a intruder to trigger malfunctions in the equipment or unauthorized changes to its configuration.

The vulnerability of the Modbus protocol implementation in microprogrammed logic controllers like Modicon Quantum is related to errors in privilege management. Exploiting this vulnerability could allow an attacker to cause service failures or unauthorized changes to the PLC’s configuration...

9.4CVSS7.7AI score0.01349EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/25 12:00 a.m.7 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium arises from incorrect restrictions on path names in the restricted access catalog. This allows unauthorized access by intruders to protected information.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium stems from incorrect restrictions on the path name in the restricted access catalog. Exploiting this vulnerability could allow an attacke...

7.8CVSS7.3AI score0.01475EPSS
SaveExploits0References3Affected Software4
BDU FSTEC
BDU FSTEC
added 2021/08/23 12:00 a.m.12 views

The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to trigger a service failure.

The vulnerability of the EcoStruxure Control Expert programming tool for programmable logic controllers is related to insufficient checking of unusual or exceptional states. Exploiting this vulnerability could allow a malicious actor to trigger a service failure remotely...

7.8CVSS7.2AI score0.01288EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/23 12:00 a.m.12 views

The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to bypass the authentication process.

The vulnerability of the programming software for PLCs programmable logic controllers, EcoStruxure Control Expert, is related to improper authentication. Exploiting this vulnerability can allow an attacker to bypass authentication processes...

7.4CVSS7.2AI score0.00327EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/23 12:00 a.m.11 views

The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to bypass the authentication process.

The vulnerability of the programming software for PLCs programmable logic controllers, EcoStruxure Control Expert, lies in the absence of restrictions on the number of authentication attempts. Exploiting this vulnerability allows a malicious actor to bypass the authentication process remotely...

9.4CVSS7.7AI score0.02757EPSS
SaveExploits0References3
Rows per page