3721 matches found
CVE-2023-33557
Fuel CMS v1.5.2 was discovered to contain a SQL injection vulnerability via the id parameter at /controllers/Blocks.php...
CVE-2023-33557
Fuel CMS v1.5.2 was discovered to contain a SQL injection vulnerability via the id parameter at /controllers/Blocks.php...
CVE-2023-33557
Fuel CMS v1.5.2 was discovered to contain a SQL injection vulnerability via the id parameter at /controllers/Blocks.php...
Firewall Whitelisting for Delivery Controllers to add Azure as a Hosting Connection
Requesting a Firewall white-list for Delivery Controller with connecting to Azure Subscription as a hosting connection...
The vulnerability of the FTP server function of microprogrammed logic controllers MELSEC RJ71EIP91, SW1DNN-EIPCT-BD, FX5-ENET/IP, SW1DNN-EIPCTFX5-BD allows a intruder to gain unauthorized access to protected information.
The vulnerability of the FTP server functions of microprogrammed logic controllers such as MELSEC RJ71EIP91, SW1DNN-EIPCT-BD, FX5-ENET/IP, and SW1DNN-EIPCTFX5-BD is related to the use of fixed password encoding. Exploiting this vulnerability can allow an intruder to gain unauthorized access to...
The vulnerability of the microprogramming software for Rockwell Automation’s ArmorStart ST controllers, related to deficiencies in the validation of user-input data, allows attackers to execute cross-site scripting (XSS) attacks.
The vulnerability of the microprogramming software for Rockwell Automation’s ArmorStart ST distributed controllers is related to deficiencies in the validation of user-input data. Exploiting this vulnerability could allow a malicious actor to perform cross-site scripting XSS attacks remotely...
The vulnerability of microprogramming software in embedded network control controllers of ASPECT Enterprise, NEXUS Series, and MATRIX Series systems relates to insecure privilege management, allowing attackers to elevate their privileges to the root level.
The vulnerability of microprogramming software in embedded network control controllers of ASPECT Enterprise, NEXUS Series, and MATRIX Series buildings is related to insecure privilege management. Exploiting this vulnerability can allow attackers to elevate their privileges to the root level...
The vulnerability of the FTP server function of microprogrammed logic controllers MELSEC RJ71EIP91, SW1DNN-EIPCT-BD, FX5-ENET/IP, SW1DNN-EIPCTFX5-BD allows a hacker to gain full access to the device.
The vulnerability of the FTP server functions of microprogrammed logic controllers such as MELSEC RJ71EIP91, SW1DNN-EIPCT-BD, FX5-ENET/IP, and SW1DNN-EIPCTFX5-BD is related to weak password requirements. Exploiting this vulnerability can allow a malicious actor to gain full access to the device...
The Software-Defined Car
Developers are starting to talk about the software-defined car. For decades, features have accumulated like cruft in new vehicles: a box here to control the antilock brakes, a module there to run the cruise control radar, and so on. Now engineers and designers are rationalizing the way they go...
CVE-2015-10111
A vulnerability was found in Watu Quiz Plugin up to 2.6.7 on WordPress. It has been rated as critical. This issue affects the function watuexams of the file controllers/exam.php of the component Exam Handler. The manipulation of the argument quiz leads to sql injection. The attack may be initiate...
CVE-2015-10111: Improper Neutralization of Special Elements used in an SQL Command
A vulnerability was found in Watu Quiz Plugin up to 2.6.7 on WordPress. It has been rated as critical. This issue affects the function watuexams of the file controllers/exam.php of the component Exam Handler. The manipulation of the argument quiz leads to sql injection. The attack may be initiate...
Mitsubishi Electric 多款产品安全漏洞
The Mitsubishi Electric MELSEC iQ-R series and the Mitsubishi Electric MELSEC iQ-F series are both programmable logic controllers from Mitsubishi Electric Japan. A security vulnerability exists in several Mitsubishi Electric products, which is caused by a missing mask when entering a password fie...
Migrate Citrix Virtual Apps and Desktop databases to a new SQL server
Please follow these steps. 1.Close all instances of Citrix studio. Any configuration changes even through powershell to be stopped while following the stepsYou can power down DDCs to be extra cautious Take VM snapshot or take backup of all Delivery Controllers. 2. Take full backup of Site, Monito...
The vulnerability of the programming software for PLCs (programmable logic controllers), namely EcoStruxure Control Exper, arises from deficiencies in the separation of the controlled system area. This allows a intruder to carry out unauthorized maintenance actions.
The vulnerability of the EcoStruxure Control Exper programming tool for programmable logic controllers is related to deficiencies in the separation of the controlled system area. Exploiting this vulnerability could allow a malicious actor to perform a service failure remotely...
The vulnerability of the Modbus TCP protocol implementation in Schneider Electric Modicon programmable logic controllers allows a intruder to trigger a service failure.
The vulnerability of the Modbus TCP protocol implementation in Schneider Electric Modicon programmable logic controllers is related to insufficient checking of unusual or exceptional states. Exploiting this vulnerability could allow a malicious actor to cause malfunctions in the service operation...
The vulnerability of the PMBus interface of the VRM Voltage Regulator Module in Supermicro BMC controllers allows a hacker to physically destroy the CPU without the ability to restore it later.
The vulnerability of the PMBus interface of the VRM Voltage Regulator Module in Supermicro BMC controllers is related to the improper assignment of permissions for the critical resource. Exploiting this vulnerability may allow an attacker to physically disable the CPU without the possibility of...
The vulnerability of Rockwell Automation’s distributed controller software ArmorStart ST, related to deficiencies in input data validation by users, allows attackers to execute cross-site scripting (XSS) attacks.
The vulnerability of the microprogramming software for Rockwell Automation’s ArmorStart ST distributed controllers is related to deficiencies in the validation of user-input data. Exploiting this vulnerability could allow a malicious actor to perform cross-site scripting XSS attacks remotely...
The vulnerability of microprogrammed software in Mitsubishi Electric Corporation’s MELSEC iQ-F Series programmable logic controllers arises from buffer overflow on the stack, allowing an intruder to trigger a malfunction or execute arbitrary code.
The vulnerability of microprogrammed software in Mitsubishi Electric Corporation’s MELSEC iQ-F series programmable logic controllers arises due to buffer overflow on the stack. Exploiting this vulnerability allows a remote attacker to cause malfunctions in the system or execute arbitrary code by...
The vulnerability of the Codesys software suite for industrial automation integrated into Schneider Electric’s programmable logic controllers allows a perpetrator to compromise data integrity.
The vulnerability of the Codesys software suite for industrial automation integrated into Schneider Electric’s programmable logic controllers is related to the disclosure of information in the incorrect data field. Exploiting this vulnerability could allow a malicious actor to compromise the...
The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert allows a intruder to trigger maintenance failures.
The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert lies in the storage of data beyond the buffer boundaries. Exploiting this vulnerability could allow a malicious actor to trigger service...