10 matches found
CVE-2026-27844
Uncaught Exception CWE-248 in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated and authorized operator to trigger a Controller restart by sending specific requests, resulting in a temporary denial of service. Version of Command Centre affected: 9.50 prior t...
CVE-2026-27844
Uncaught Exception CWE-248 in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated and authorized operator to trigger a Controller restart by sending specific requests, resulting in a temporary denial of service. Version of Command Centre affected: 9.50 prior t...
EUVD-2026-42002
Uncaught Exception CWE-248 in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated and authorized operator to trigger a Controller restart by sending specific requests, resulting in a temporary denial of service. Version of Command Centre affected: 9.50 prior t...
CVE-2026-27844
CVE-2026-27844 affects Command Centre Controller 6000/7000 diagnostic web interfaces. An uncaught exception (CWE-248) from specific requests by an authenticated and authorized operator can trigger a Controller restart, causing a temporary denial of service. Affected versions include 9.50 (prior t...
KB5010794: Out-of-band update for Windows 8.1 and Windows Server 2012 R2: January 17, 2022
KB5010794: Out-of-band update for Windows 8.1 and Windows Server 2012 R2: January 17, 2022 Summary This update resolves the following issues: Virtual machines VMs located on a server that has Unified Extensible Firmware Interface UEFI enabled fail to start after installing the January 11, 2022...
The vulnerability of the SINAMICS PERFECT HARMONY GH180 driver software, related to configuration parameter errors, allows a hacker to cause the controller to restart.
The vulnerability of SINAMICS PERFECT HARMONY GH180 driver software is related to configuration errors. Exploiting this vulnerability could allow an attacker, who has access to the device via the field bus, to cause the controller to restart by performing read/write requests for parameters...
CVE-2019-6574
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...
CVE-2019-6574
CVE-2019-6574 affects Siemens SINAMICS PERFECT HARMONY GH180 (NXG I/NXG II) with MLFBs 6SR2...-, 6SR3...-, 6SR4...- (options G21–G46). Root cause: improperly configured Parameter Read/Write execution via Fieldbus network, enabling a remote attacker with network access to restart the controller an...
April 17, 2018—KB4093121 (Preview of Monthly Rollup)
None None...
November 27, 2017—KB4050946 (Preview of Monthly Rollup)
None None...