1496 matches found
Fuji Electric FRENIC Loader
1. EXECUTIVE SUMMARY CVSS v3 4.4 ATTENTION: Low skill level to exploit Vendor: Fuji Electric Equipment: FRENIC Loader Vulnerability: Out-of-Bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability could allow information disclosure. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS...
LCDS LAquis SCADA LQS File Parsing
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: LCDS—Leão Consultoria e Desenvolvimento de Sistemas LTDA ME Equipment: LAquis SCADA Vulnerabilities: Out-of-bounds Read, Type Confusion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...
CISA Releases Advisory on Wind River VxWorks Platform
The Cybersecurity and Infrastructure Security Agency CISA has released an Industrial Control Systems ICS Advisory on multiple vulnerabilities in the Wind River VxWorks Platform. A remote attacker could exploit some of these vulnerabilities to take control of an affected system. CISA encourages...
icsmaster
This repository is an offensive tool for ICS Industrial Control Systems security research and exploitation. It contains a collection of resources, including papers, exploits, firmware, Nmap scripts, and tools, related to ICS security. The repository is maintained by GeneBlue and appears to be a...
How Will Companies Deploy Industrial IoT Security Solutions?
Industrial IoT IIoT devices will comprise the majority of the billions of IoT devices deployed over the next decade. How will the information security market meet this onslaught of technology? The consumer market is not a useful guide for this analysis. Consumers buy in small quantities and choos...
ICSA-19-192-04 Siemens SIMATIC RF6XXR
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION : Exploitable remotely/public exploits are available Vendor : Siemens Equipment : SIMATIC RF6XXR Vulnerabilities : Improper Input Validation, Cryptographic Issues 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow access to...
TRISIS Group, Known for Physical Destruction, Targets U.S. Electric Companies
XENOTIME, the APT group behind the TRISIS industrial control system ICS event, has expanded its focus beyond the oil and gas industries, according to researchers. The group has recently been seen probing the networks of electric utility organizations in the U.S. and elsewhere – perhaps a precurso...
Schneider Electric Altivar ATV71HU55M3Z Variable Speed Drive
Binary data 764269.prm...
The vulnerability of Siemens SIMATIC process control systems, related to errors in network access restrictions, allows a intruder to execute arbitrary code.
The vulnerability of the Siemens SIMATIC process control system is related to errors in network access restrictions, if “encrypted communication” is not utilized. Exploiting this vulnerability allows a perpetrator who has not undergone identity verification to execute arbitrary codes...
Fuji Electric Alpha7 PC Loader
1. EXECUTIVE SUMMARY CVSS v3 3.3 ATTENTION: Low skill level to exploit Vendor: Fuji Electric Equipment: Alpha7 PC Loader Vulnerability: Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The...
ICSA-19-134-05 Siemens SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could...
Schweitzer Engineering Laboratories Communications Processor Communications Processor Detection
Binary data 755331.prm...
Rockwell Automation/Allen-Bradley ControlLogix Industrial Computer Detection
Binary data 750023.prm...
Beckhoff CP7731-0000-0050 Industrial Computer Detection
Binary data 763287.prm...
SAS 2019: Triton ICS Malware Hits A Second Victim
SINGAPORE – The group behind the Triton malware, which first came to light after a disruptive critical-infrastructure attack on Saudi oil giant Petro Rabigh in 2017, has found a second victim. According to researchers at FireEye, the cybercriminals behind Triton, also called Trisis, have once aga...
Siemens Spectrum Power Command Injection Vulnerability
Siemens Spectrum Power is a system that provides essential components for SCADA, communication and data modeling of control and monitoring systems. A command injection vulnerability exists in Siemens Spectrum Power, which can be exploited by an attacker to execute operating system commands...
The vulnerability of kernel drivers for software automation and process control systems in TwinCAT allows a hacker to gain increased privileges.
The vulnerability of the kernel drivers of software for automation and control systems in TwinCAT exists due to insufficient testing of input data. Exploiting this vulnerability can allow attackers to gain increased privileges...
Hacking Superyachts. Advice for captains
I’ve blogged already about how superyachts are the homes, the offices, the play areas for their owners. However, they are also the charge of the captains and homes of the crew, most owners simply see themselves as guests on the captain’s yacht, so what do you the captain and crew need to think...
Podcast: The High-Risk Threats Behind the Norsk Hydro Cyberattack
Norway-based Norsk Hydro announced on Tuesday morning it was victim to a ransomware attack, which forced the global aluminum producer to shut down or isolate several plants and send several more into manual mode, the company said on Tuesday morning. The cyberattack, first detected by the company’...
Triton
Good article on the Triton malware which targets industrial control systems...