Lucene search
+L

1519 matches found

CNNVD
CNNVD
added 2022/08/19 12:00 a.m.12 views

Siemens部分产品 安全漏洞

SIMATIC PC Station is a software component that manages SIMATIC software products and interfaces on a PC.SIMATIC S7-400 controllers are designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and chemical industries around the world. A...

7.5CVSS7.1AI score0.00716EPSS
SaveExploits0References3
Trellix
Trellix
added 2022/08/18 12:00 a.m.29 views

A Door Isn’t a Door When It’s Ajar - Part 2

A Door Isn’t a Door When It’s Ajar - Part II By Trellix · August 18, 2022 This story was also written by Steve Povolny and Sam Quinn Contents Introduction Software Hacking Software Hacking Shopping List Vulnerabilities Discovered CVE-2022-31479: Command injection via the web interface Vulnerable...

9.5AI score0.02406EPSS
SaveExploits0
Trellix
Trellix
added 2022/08/18 12:00 a.m.36 views

A Door Isn’t a Door When It’s Ajar - Part 2

A Door Isn’t a Door When It’s Ajar - Part II By Trellix · August 18, 2022 This story was also written by Steve Povolny and Sam Quinn Contents Introduction Software Hacking Software Hacking Shopping List Vulnerabilities Discovered CVE-2022-31479: Command injection via the web interface Vulnerable...

10CVSS8.5AI score0.02406EPSS
SaveExploits0
CISA
CISA
added 2022/08/18 12:00 a.m.25 views

CISA releases 5 Industrial Control Systems Advisories

CISA has released 5 Industrial Control Systems ICS advisories on August 18, 2022. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories for...

0.8AI score
SaveExploits0References5
ICS
ICS
added 2022/08/16 12:00 a.m.57 views

Yokogawa CENTUM Controller FCS

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Yokogawa Equipment: CENTUM VP & CS 3000 Controller FCS Vulnerability: Denial of Service 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the affected device, resulting in a...

7.5CVSS7.7AI score0.01174EPSS
SaveExploits0References5
Trellix
Trellix
added 2022/08/11 12:00 a.m.50 views

A Door Isn’t a Door When It’s Ajar- Part 1

A Door Isn’t a Door When It’s Ajar - Part 1 By Trellix · August 11, 2022 This story was also written by Steve Povolny and Sam Quinn Contents Executive Summary Target Selection What is it? Reconnaissance & Standard Operations Recon Standard Operations Hardware Hacking Hardware Hacking Shopping Lis...

10CVSS8.7AI score0.02406EPSS
SaveExploits0
ICS
ICS
added 2022/08/09 12:00 a.m.103 views

Emerson ControlWave

1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Emerson Equipment: ControlWave Vulnerabilities: Insufficient Verification of Data Authenticity CISA is aware of a public report, known as “OT:ICEFALL,” that details vulnerabilities found in multiple...

7.8CVSS8AI score0.00179EPSS
SaveExploits0References5
ICS
ICS
added 2022/08/04 12:00 a.m.56 views

Digi ConnectPort X2D

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Digi International, Inc. Equipment: ConnectPort X2D Gateway Vulnerability: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker...

10CVSS9.8AI score0.00956EPSS
SaveExploits0References5
ICS
ICS
added 2022/07/26 12:00 a.m.119 views

Honeywell Saia Burgess PG5 PCD

1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Exploitable on adjacent network/low attack complexity Vendor: Honeywell Equipment: Saia Burgess PG5 PCD Vulnerabilities: Authentication Bypass, Use of a Broken or Risky Cryptographic Algorithm CISA is aware of a public report known as “OT:ICEFALL” that...

8.1CVSS6.9AI score0.00704EPSS
SaveExploits0References4
ICS
ICS
added 2022/07/26 12:00 a.m.110 views

Inductive Automation Ignition

1. EXECUTIVE SUMMARY CVSS v3 8.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Inductive Automation Equipment: Ignition Vulnerability: Improper Restriction of XML External Entity Reference 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled...

9.8CVSS9.6AI score0.00956EPSS
SaveExploits0References5
HackRead
HackRead
added 2022/07/15 6:34 p.m.20 views

CIA Whistleblower Found Guilty of Leaking Vault 7 Documents to WikiLeaks

By Deeba Ahmed The Vault 7 leak included trojans, viruses, malware, zero-day exploits, malware remote control systems, and related documents dating… This is a post from HackRead.com Read the original post: CIA Whistleblower Found Guilty of Leaking Vault 7 Documents to WikiLeaks...

2.8AI score
SaveExploits0
ICS
ICS
added 2022/07/07 12:00 a.m.50 views

Rockwell Automation MicroLogix

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: MicroLogix 1100/1400 Vulnerability: Improper Restriction of Rendered UI Layers or Frames 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...

6.5CVSS6.8AI score0.01141EPSS
SaveExploits0References4
Circl
Circl
added 2022/07/02 12:40 a.m.8 views

CVE-2022-32087

creationtimestamp| type| source ---|---|--- 2022-07-02 00:40:12+00:00| seen| https://t.me/cibsecurity/45541 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...

7.5CVSS7.9AI score0.01807EPSS
SaveExploits1References2
Circl
Circl
added 2022/07/02 12:40 a.m.5 views

CVE-2022-32088

creationtimestamp| type| source ---|---|--- 2022-07-02 00:40:10+00:00| seen| https://t.me/cibsecurity/45539 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...

7.5CVSS7.9AI score0.01913EPSS
SaveExploits1References2
ICS
ICS
added 2022/06/30 12:00 p.m.67 views

CODESYS Gateway Server (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: CODESYS GmbH Equipment: CODESYS Gateway Server Vulnerability: Heap Based Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-15-258-02 3S...

7.5CVSS7.6AI score0.0621EPSS
SaveExploits0References27
The Hacker News
The Hacker News
added 2022/06/28 11:30 a.m.224 views

APT Hackers Targeting Industrial Control Systems with ShadowPad Backdoor

Entities located in Afghanistan, Malaysia, and Pakistan are in the crosshairs of an attack campaign that targets unpatched Microsoft Exchange Servers as an initial access vector to deploy the ShadowPad malware. Russian cybersecurity firm Kaspersky, which first detected the activity in mid-October...

9.8CVSS2.2AI score0.99996EPSS
SaveExploits65
Positive Technologies
Positive Technologies
added 2022/06/28 12:00 a.m.11 views

PT-2022-4220 · Yokogawa · Exaopc +5

Name of the Vulnerable Software and Affected Versions: CENTUM CS 3000 versions R3.08.10 through R3.09.00 CENTUM VP versions R4.01.00 through R4.03.00 CENTUM VP versions R5.01.00 through R5.04.20 CENTUM VP versions R6.01.00 through R6.09.00 Exaopc versions R3.72.00 through R3.80.00 B/M9000 CS...

8.8CVSS8.3AI score0.0058EPSS
SaveExploits0References7
BDU FSTEC
BDU FSTEC
added 2022/06/28 12:00 a.m.17 views

The vulnerability of Emerson DeltaV industrial control stations, related to the use of cryptographic algorithms containing vulnerabilities, allows an intruder to gain access to the system’s control interface.

The vulnerability of Emerson DeltaV industrial control stations lies in the use of cryptographic algorithms that contain vulnerabilities. Exploiting this vulnerability can allow an attacker operating remotely to gain access to the system’s control interface...

9CVSS5.5AI score0.00175EPSS
SaveExploits0References2
ICS
ICS
added 2022/06/28 12:00 a.m.78 views

Motorola Solutions MOSCAD IP and ACE IP Gateways

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely Vendor: Motorola Solutions Equipment: MOSCAD IP Gateway and ACE IP Gateway Vulnerability: Missing Authentication for Critical Function CISA is aware of a public report, known as “OT:ICEFALL” that details vulnerabilities found in...

7.5CVSS8AI score0.00777EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2022/06/27 12:00 a.m.12 views

The vulnerability of the EpicMo protocol lies in its ability to exploit measurement-and-control controllers from the Experion LX, allowing attackers to cause service failures.

The vulnerability of the EpicMo protocol, which is implemented in measurement and control controllers of the Experion LX, is related to deficiencies in the authentication process. Exploiting this vulnerability could allow a malicious actor to cause service failures remotely...

7.8CVSS5.5AI score0.00849EPSS
SaveExploits0References4
Rows per page
Query Builder