Lucene search
+L

276 matches found

CVE
CVE
added 2020/11/19 9:4 p.m.65 views

CVE-2020-7538

CVE-2020-7538 affects the PLC Simulator for EcoStruxure Control Expert (Unity Pro) across all versions. The flaw is CWE-754: Improper Check for Unusual or Exceptional Conditions, which could crash the PLC simulator when it receives a specially crafted Modbus request. Affected: PLC Simulator for E...

7.5CVSS7.5AI score0.01272EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/11/19 9:3 p.m.60 views

CVE-2020-28213

Across multiple sources, CVE-2020-28213 affects Schneider Electric EcoStruxure Control Expert (Unity Pro) PLC Simulator, with the flaw lying in downloading code without integrity checking via Modbus. The vulnerability allows unauthorized command execution on all versions, as reported in CVE recor...

8.8CVSS8.8AI score0.01129EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:3 p.m.43 views

CVE-2020-28213

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when sending specially crafted requests over Modbus...

8.9AI score0.01129EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/11/19 9:3 p.m.29 views

CVE-2020-28212

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when a brute force attack is done over Modbus...

9.6AI score0.02642EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/19 9:3 p.m.67 views

CVE-2020-28212

CVE-2020-28212 describes an authentication- bypass risk in EcoStruxure Control Expert PLC Simulator (Unity Pro) via brute-forcing Modbus sessions. Root cause: CWE-307 improper restriction of excessive authentication attempts, enabling a remote attacker to gain unauthorized command execution with ...

9.8CVSS9.5AI score0.02642EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:3 p.m.22 views

CVE-2020-28211

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause bypass of authentication when overwriting memory using a debugger...

7.8AI score0.00323EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/19 9:3 p.m.63 views

CVE-2020-28211

CVE-2020-28211 affects Schneider Electric EcoStruxure Control Expert (PLC Simulator) with an Incorrect Authorization weakness (CWE-863) that could allow authentication bypass by overwriting memory via a debugger. Affected software is EcoStruxure Control Expert (Unity Pro) across all versions; the...

7.8CVSS7.7AI score0.00323EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.10 views

Schneider Electric Unity Pro 安全漏洞

Schneider Electric EcoStruxure Control Expert is the universal programming, commissioning and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A command execution vulnerability exists in Schneider Electric EcoStruxure Control Expert. The vulnerability...

8.8CVSS7.6AI score0.01129EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2020/11/19 12:0 a.m.11 views

PT-2020-6317 · Schneider Electric · Ecostruxure Control Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert all versions Description: The issue is related to the lack of restrictions on authentication attempts, which could allow a remote attacker to bypass the authentication procedure. This vulnerability may lead to...

9.8CVSS9.6AI score0.02642EPSS
SaveExploits0References8
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.11 views

Schneider Electric EcoStruxure Control Expert Security Vulnerability

Schneider Electric EcoStruxure Control Expert formerly known as Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A security vulnerability exists in EcoStruxure Control Expert that stems from a specially crafted request...

7.5CVSS7.1AI score0.01882EPSS
SaveExploits1References3
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.13 views

Schneider Electric EcoStruxure Control Expert 授权问题漏洞

EcoStruxure Control Expert is the universal programming, debugging and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A security vulnerability exists in PLC Simulator in EcoStruxure Control Expert. The vulnerability can be exploited by an attacker to...

9.8CVSS7.3AI score0.02642EPSS
SaveExploits0References2
NCSC
NCSC
added 2020/11/13 12:0 a.m.10 views

Vulnerability fixed in EcoStruxure Control Expert

A vulnerability has been fixed that could cause a crash of the PLC simulator in EcoStruxure Control Expert software when a specially crafted request is received via Modbus. Schneider Electric has made available a firmware update that fixes the vulnerability. For more information, see:...

7.5CVSS6.9AI score0.01272EPSS
SaveExploits0
CNVD
CNVD
added 2020/11/12 12:0 a.m.13 views

Schneider Electric EcoStruxure Control Expert PLC Denial of Service Vulnerability

Schneider Electric EcoStruxure Control Expert formerly Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A denial of service vulnerability exists in EcoStruxure Control Expert's PLC simulator, which originates when a...

7.5CVSS6.7AI score0.01272EPSS
SaveExploits0References1
ICS
ICS
added 2020/11/10 12:0 a.m.72 views

Schneider Electric PLC Simulator for EcoStruxure Control Expert

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: PLC Simulator for EcoStruxure Control Expert Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this...

7.5CVSS7.8AI score0.01272EPSS
SaveExploits0References5
CNVD
CNVD
added 2020/11/02 12:0 a.m.2 views

Unauthorized Access Vulnerability in Microprocessor Industries Access Control Specialist

Shenzhen Weikeng Industrial Co., Ltd. is a professional manufacturer and developer of access control systems, access control equipment and access control software in China. An unauthorized access vulnerability exists in Weikeng Industrial's Access Control Expert. An attacker can exploit this...

6.7AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2020/04/30 12:0 a.m.7 views

The vulnerability of the programming software for PLCs (programmable logic controllers), namely EcoStruxure Control Expert, is related to deficiencies in access control. This vulnerability allows a intruder to bypass the authentication process between EcoStruxure Control Expert and the PLC.

The vulnerability of the EcoStruxure Control Expert programming tool for programmable logic controllers is related to deficiencies in access control. Exploiting this vulnerability could allow a malicious actor to bypass the authentication process between the EcoStruxure Control Expert and the...

7.5CVSS7.2AI score0.00955EPSS
SaveExploits0References3
CNVD
CNVD
added 2020/04/03 12:0 a.m.3 views

Denial of Service Vulnerability in Control Expert

Control Expert formerly known as Unity Pro is a PLC configuration software from Schneider, through which you can complete the PLC program writing as well as down loading operations. A denial of service vulnerability exists in Control Expert, which can be exploited by an attacker to cause a denial...

6.8AI score
SaveExploits0
CNVD
CNVD
added 2020/03/24 12:0 a.m.5 views

Injection Vulnerability in Multiple Schneider Electric Products

The Schneider Electric Modicon M580 is a programmable automation controller from Schneider Electric, France.The Schneider Electric Modicon M340 is a medium range PLC programmable logic controller for industrial processes and infrastructure. Schneider Electric Modicon M580 is a programmable...

9.8CVSS9.4AI score0.01542EPSS
SaveExploits0References1
OSV
OSV
added 2020/03/23 7:15 p.m.4 views

CVE-2020-7475

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...

9.8CVSS7.4AI score
SaveExploits0References1
Prion
Prion
added 2020/03/23 7:15 p.m.20 views

Design/Logic Flaw

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...

7.5CVSS9.2AI score0.01542EPSS
SaveExploits0References1Affected Software3
Rows per page