177 matches found
CVE-2023-28399
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
CVE-2023-28651
Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...
CVE-2023-29154
SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...
CVE-2023-28713
Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...
CVE-2023-28399
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
CVE-2023-28657
Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...
CVE-2023-28399
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
CVE-2023-28824
Server-side request forgery vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database...
Cross site scripting
Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...
Server side request forgery (ssrf)
Server-side request forgery vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database...
Improper access control
Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...
Code injection
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
Sql injection
SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...
CVE-2023-28651
CONPROSYS HMI System (CHS)
CVE-2023-28651
Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...
CVE-2023-28657
CVE-2023-28657 refers to an improper access control vulnerability in CONPROSYS HMI System (CHS) versions prior to 3.5.3. The affected product runs on CHS where a local PC user may gain administrative privileges, potentially exposing and modifying product information. The CVE is associated with CH...
CVE-2023-28824
Server-side request forgery vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database...
CVE-2023-29154
SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...
PT-2023-21693 · Unknown · Conprosys Hmi System
Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI System CHS versions prior to 3.5.3 Description: The issue is related to incorrect permission assignment for a critical resource in the CONPROSYS HMI System CHS. The Access Control List ACL is not set correctly for the local fold...
CVE-2023-28824
CVE-2023-28824 affects Contec CONPROSYS HMI System (CHS) prior to version 3.5.3. The issue is a server-side request forgery (SSRF) vulnerability where an administrator can bypass the query-setting database restrictions and connect to a user-unintended database. Root cause details in connected doc...