3942 matches found
Important: Red Hat Security Advisory: Submariner v0.21 security fixes and container updates
Submariner v0.21 General Availability release images, which provide enhancements, security fixes, and updated container images. Red Hat Product Security has rated this update as having a security impact of Important. A Common Vulnerability Scoring System CVSS base score, which gives a detailed...
CVE-2025-3756
A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication...
CVE-2026-3048
An authenticated administrator who configures or tests LDAP connectivity in Sonatype Nexus Repository Manager versions 3.0.0 through 3.91.1 may be able to initiate unintended server-side connections when interacting with a malicious LDAP server...
CVE-2026-20772
Uncontrolled search path for some IntelR Connectivity Performance Suite software installers before version 50.25.1121.193 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may...
CVE-2026-50207
The system Binder boundary accepts unverified pass-through AT commands, giving local applications the power to read baseband files or disable cellular connectivity...
CVE-2026-0826
In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...
CVE-2026-50207
The CVE-2026-50207 issue involves the system Binder boundary that accepts unverified pass-through AT commands, enabling local applications to read baseband files or disable cellular connectivity. The vulnerability is described as local, with impact to confidentiality, integrity, and availability ...
PT-2026-46159
The system Binder boundary accepts unverified pass-through AT commands, giving local applications the power to read baseband files or disable cellular connectivity...
CVE-2019-25720
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25720
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25720
This CVE affects Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). The vulnerability is a denial-of-service caused by processing a malformed network packet, allowing an unauthenticated attacker to reboot the monitor. Repeated malformed packets can disrupt patient ...
EUVD-2019-20161
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25724
The CVE-2019-25724 entry describes a network-based Denial of Service impacting Dräger Infinity M300 patient-worn monitors running VG2.x and earlier. The underlying issue allows an attacker with access to the hospital network or Infinity Network to repeatedly trigger device reboots, driving the de...
CVE-2019-25722
The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...
CVE-2026-0826
In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...
CVE-2026-0826 Poly Voice – Possible Remote Control of Certain Poly Devices
In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...