CVE-2019-25720

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS
Exploits0References2
Vulnrichment
Vulnrichment
added yesterday2 views

CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score
Exploits0References2
CVE
CVE
added yesterday4 views

CVE-2019-25720

This CVE affects Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). The vulnerability is a denial-of-service caused by processing a malformed network packet, allowing an unauthenticated attacker to reboot the monitor. Repeated malformed packets can disrupt patient ...

7.1CVSS5.8AI score
Exploits0References2
ATTACKERKB
ATTACKERKB
added yesterday1 views

CVE-2019-25720

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score
Exploits0References3
EUVD
EUVD
added yesterday2 views

EUVD-2019-20161

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score
Exploits0References2
NVD
NVD
added 2 days ago1 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00016EPSS
Exploits0References2
CVE
CVE
added 2 days ago9 views

CVE-2019-25724

The CVE-2019-25724 entry describes a network-based Denial of Service impacting Dräger Infinity M300 patient-worn monitors running VG2.x and earlier. The underlying issue allows an attacker with access to the hospital network or Infinity Network to repeatedly trigger device reboots, driving the de...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
CVE
CVE
added 2 days ago5 views

CVE-2019-25722

The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...

7.6CVSS5.9AI score0.00043EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2 days ago2 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References3
Cvelist
Cvelist
added 3 days ago23 views

CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.00046EPSS
Exploits0References2
NVD
NVD
added 3 days ago7 views

CVE-2026-0826

In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...

9.2CVSS0.00212EPSS
Exploits0References1
EUVD
EUVD
added 3 days ago6 views

EUVD-2026-33658

In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...

9.2CVSS6.6AI score0.00212EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 3 days ago5 views

CVE-2026-0826 Poly Voice – Possible Remote Control of Certain Poly Devices

In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...

9.2CVSS6.6AI score0.00212EPSS
Exploits0References1
ATTACKERKB
ATTACKERKB
added 3 days ago6 views

CVE-2026-0826

In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...

9.2CVSS6.6AI score0.00212EPSS
Exploits0References2
Cvelist
Cvelist
added 3 days ago26 views

CVE-2026-0826 Poly Voice – Possible Remote Control of Certain Poly Devices

In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform...

9.2CVSS0.00212EPSS
Exploits0References1
CVE
CVE
added 3 days ago12 views

CVE-2026-0826

In CVE-2026-0826, the issue is a stack-based buffer overflow in the Poly Voice device parser for ICE SDP attributes. When ICE is enabled, parsing the a=candidate: line copies input into a 256-byte stack buffer without length checks, enabling crafted SDP to overflow and achieve unauthenticated rem...

9.2CVSS6.6AI score0.00212EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 3 days ago12 views

PT-2026-45564

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS5.8AI score0.00046EPSS
Exploits0References2
Packet Storm News
Packet Storm News
added 3 days ago3 views

Apache ActiveMQ Jolokia Security Auditor

This is a security assessment tool for Apache ActiveMQ deployments that expose the Jolokia management interface. It verifies connectivity, evaluates authentication status, retrieves Jolokia agent information, and identifies accessible ActiveMQ broker instances through JMX endpoints...

5.8AI score
Exploits0
Positive Technologies
Positive Technologies
added 3 days ago8 views

PT-2026-45420

Name of the Vulnerable Software and Affected Versions Poly Voice VVX 150 Poly Voice VVX 250 Poly Voice VVX 350 Poly Voice VVX 450 Poly Voice Trio 8300 Poly Voice Trio 8500 Poly Voice Trio 8800 Description A stack-based buffer overflow exists in Poly Voice products on the Linux platform during the...

9.2CVSS6.5AI score0.00212EPSS
Exploits0References15
Hewlett-Packard
Hewlett-Packard
added 3 days ago3 views

Poly Voice – Possible Remote Control of Certain Poly Devices

In certain scenarios when the admin has enabled Interactive Connectivity Establishment ICE, a buffer overflow could enable remote code execution on Poly Voice products on the Linux platform. HP Poly recommends admins disable ICE connectivity when not required...

9.2CVSS6.6AI score0.00212EPSS
Exploits0
Rows per page
Query Builder