17284 matches found
CVE-2023-29104
Summary: CVE-2023-29104 affects Siemens SIMATIC Cloud Connect 7 CC712 and CC716. The issue is a path traversal vulnerability in the upload feature of the device’s web-based management, allowing an authenticated privileged attacker to overwrite files that the ccuser Linux user can write to, or dow...
CVE-2023-29104
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1. The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacke...
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-29103
The CVE-2023-29103 entry concerns Siemens SIMATIC Cloud Connect 7 CC712/CC716 with versions 2.0–2.1, where a hard-coded password protects diagnostic files, enabling an authenticated attacker to access protected data. Red Hat and NVD entries corroborate the affected products and vulnerability clas...
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-28832
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1. The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to...
CVE-2023-28832
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1. The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to...
CVE-2023-28832
Siemens SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) and CC716 (6GK1411-5AC00) are affected for versions 2.0 to 2.1. The issue is a web-based management input validation flaw that enables command injection, allowing an authenticated privileged remote attacker to execute arbitrary code with root ...
kernel: use-after-free caused by invalid pointer hostname in fs/cifs/connect.c
A use-after-free flaw was found in reconnsetipaddrfromhostname in fs/cifs/connect.c in the Linux kernel. The issue occurs when it forgets to set the free pointer server-hostname to NULL, leading to an invalid pointer request...
kernel: RDMA/siw: Fix duplicated reported IW_CM_EVENT_CONNECT_REPLY event
In the Linux kernel, the following vulnerability has been resolved: RDMA/siw: Fix duplicated reported IWCMEVENTCONNECTREPLY event If siwrecvmparr returns -EAGAIN, it means that the MPA reply hasn't been received completely, and should not report IWCMEVENTCONNECTREPLY in this case. This may trigge...
kernel: use-after-free in l2cap_connect and l2cap_le_connect_req in net/bluetooth/l2cap_core.c
A use-after-free flaw was found in the Linux kernel's implementation of logical link control and adaptation protocol L2CAP, part of the Bluetooth stack in the l2capconnect and l2capleconnectreq functions. An attacker with physical access within the range of standard Bluetooth transmission could...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in SIMATIC Cloud Connect, Siveillance, SINEC, Solid Edge and Scalance products. The vulnerabilities potentially enable a malicious party to launch attacks execute attacks that could result in the following categories of damage: Denial-of-Service DoS Manipulation ...
PT-2025-25905 · Linux +1 · Linux Kernel +1
Name of the Vulnerable Software and Affected Versions: Linux kernel versions prior to 5.18.0 Description: A refcount bug in the Linux kernel has been resolved. The issue occurs during the SMC fallback process in the connect syscall, where the kernel replaces TCP with SMC and sets the clcsk-sk use...
PT-2023-22154
Name of the Vulnerable Software and Affected Versions SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1 Description A vulnerability has been identified where the export endpoint is accessible via REST API without authentication. This cou...
Siemens SIMATIC Cloud Connect 信息泄露漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. An information disclosure vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be...
PT-2023-21995 · Siemens · Simatic Cloud Connect 7 Cc712 +1
Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1 Description: A vulnerability has been identified where the web-based management of affected devices does not properly validate user...
CVE-2023-29105: Missing Standardized Error Handling Mechanism
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device is vulnerable to a denial of service while parsing a random non-JSON MQTT payload. This could allow an attacker who can...
CVE-2023-29103: Use of Hard-coded Password
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-29107: Files or Directories Accessible to External Parties
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1. The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources...
Siemens SIMATIC Cloud Connect 路径遍历漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A path traversal vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited by a...