715 matches found
CVE-2020-4135: Undefined Security Weakness
IBM DB2 for Linux, UNIX and Windows includes DB2 Connect Server 9.7, 10.1, 10.5, 11.1, and 11.5 could allow an unauthenticated user to send specially crafted packets to cause a denial of service from excessive memory usage...
CVE-2020-4230: Undefined Security Weakness
IBM DB2 for Linux, UNIX and Windows includes DB2 Connect Server 11.1 and 11.5 is vulnerable to an escalation of privilege when an authenticated local attacker with special permissions executes specially crafted Db2 commands. IBM X-Force ID: 175212...
PT-2020-6088
Name of the Vulnerable Software and Affected Versions IBM DB2 for Linux, UNIX and Windows includes DB2 Connect Server version 11.5 Description The issue is related to insufficient sanitization of special elements in output used by an incoming component, which can be exploited by a remote attacker...
PT-2020-6090
Name of the Vulnerable Software and Affected Versions IBM DB2 for Linux, UNIX and Windows includes DB2 Connect Server versions 10.5, 11.1, and 11.5 Description The issue is related to a denial of service that can be caused by an authenticated attacker sending specially crafted commands. It is als...
The vulnerability of the IBM DB2 database management system and the IBM DB2 Connect Server automatic redirection server, related to the use of an unreliable path, allows a perpetrator to gain unauthorized access to protected information.
The vulnerability of the IBM DB2 database management system and the IBM DB2 Connect Server automatic redirection server lies in the use of an unreliable path. Exploiting this vulnerability can allow attackers to gain unauthorized access to protected information by downloading a malicious library...
Siemens SINEMA Remote Connect Server ICSA-19-260-02 Multiple Security Vulnerabilities
Description Siemens SINEMA Remote Connect Server is prone to following security vulnerabilities: 1. Multiple security vulnerabilities 2. An information-disclosure vulnerability 3. A cross-site-request forgery vulnerability An attacker may leverage these issues to obtain potentially sensitive...
CVE-2019-13922
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect...
CVE-2019-13920
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. Some parts of the web application are not protected against Cross Site Request Forgery CSRF attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a...
CVE-2019-13918
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user...
CVE-2019-13922
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect...
CVE-2019-13919
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid...
CVE-2019-13920
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. Some parts of the web application are not protected against Cross Site Request Forgery CSRF attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a...
CVE-2019-13918
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user...
Design/Logic Flaw
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect...
Cross site request forgery (csrf)
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. Some parts of the web application are not protected against Cross Site Request Forgery CSRF attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a...
Design/Logic Flaw
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user...
Design/Logic Flaw
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid...
CVE-2019-13920
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. Some parts of the web application are not protected against Cross Site Request Forgery CSRF attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a...
CVE-2019-13918
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0 SP1. The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user...
CVE-2019-13920
Siemens SINEMA Remote Connect Server, pre-2.0 SP1, has a Cross‑Site Request Forgery (CSRF) vulnerability in the web interface that could allow an attacker to trigger requests from a logged‑in user and switch the connectivity state of a user or device. Root cause: CSRF in the web application (CVE-...