Lucene search
+L

6 matches found

RedhatCVE
RedhatCVE
added 2026/08/22 11:48 a.m.9 views

CVE-2026-77584

A flaw was found in Tor where a malicious client could trigger a use-after-free UAF vulnerability. This occurs when the software fails to properly manage memory after a circuit is freed, specifically due to the improper handling of CONFLUXLINK cells on circuits with attached streams. By sending a...

7CVSS4.9AI score0.00176EPSS
SaveExploits0References2
SUSE CVE
SUSE CVE
added 2026/08/22 12:50 a.m.8 views

SUSE CVE-2026-77584

Tor before 0.4.9.10 did not reject a CONFLUXLINK cell that arrives on a circuit which already has attached streams. A malicious client could send a RELAYCOMMANDBEGIN before the CONFLUXLINK on the same circuit, attaching an exit stream that would later end up orphan leaving a dangling circuit...

7CVSS5.5AI score0.00176EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2026/08/21 12:00 a.m.14 views

Linux Distros Unpatched Vulnerability : CVE-2026-77584

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Tor before 0.4.9.10 did not reject a CONFLUXLINK cell that arrives on a circuit which already has attached streams. A malicious client could send a...

7CVSS5.8AI score0.00176EPSS
SaveExploits0References2
OSV
OSV
added 2026/08/20 9:17 p.m.12 views

DEBIAN-CVE-2026-77584

Tor before 0.4.9.10 did not reject a CONFLUXLINK cell that arrives on a circuit which already has attached streams. A malicious client could send a RELAYCOMMANDBEGIN before the CONFLUXLINK on the same circuit, attaching an exit stream that would later end up orphan leaving a dangling circuit...

7CVSS5.6AI score0.00176EPSS
SaveExploits0References1
Debian CVE
Debian CVE
added 2026/08/20 8:38 p.m.11 views

CVE-2026-77584

Tor before 0.4.9.10 did not reject a CONFLUXLINK cell that arrives on a circuit which already has attached streams. A malicious client could send a RELAYCOMMANDBEGIN before the CONFLUXLINK on the same circuit, attaching an exit stream that would later end up orphan leaving a dangling circuit...

7CVSS5.5AI score0.00176EPSS
SaveExploits0
EUVD
EUVD
added 2026/08/20 8:38 p.m.14 views

EUVD-2026-63591

Tor before 0.4.9.10 did not reject a CONFLUXLINK cell that arrives on a circuit which already has attached streams. A malicious client could send a RELAYCOMMANDBEGIN before the CONFLUXLINK on the same circuit, attaching an exit stream that would later end up orphan leaving a dangling circuit...

7CVSS5.4AI score0.00176EPSS
SaveExploits0References1
Rows per page