Siemens SIMATIC RF188CI 6GT2002-0JE40 RFID Communication Module Detection
Binary data 765269.prm...
PT-2019-3834
Name of the Vulnerable Software and Affected Versions Modicon M580 CPU BMEx58 versions affected versions not specified Modicon M580 communication module BMENOC0311, BMENOC0321 versions affected versions not specified Description A vulnerability exists in the handling of exceptional conditions,...
PT-2019-4787
Name of the Vulnerable Software and Affected Versions SIMATIC TDC CP51M1 versions prior to V1.1.7 Description The issue is related to insufficient data validation when handling UDP traffic in the communication module of the Siemens SIMATIC TDC CP51M1. This can be exploited by a remote attacker to...
The vulnerability of Siemens CP’s communication module’s microprogramming software, related to the lack of protective measures for website structures, allows attackers to carry out cross-site scripting attacks.
The vulnerability of Siemens CP’s communication module’s microprogramming software is related to the lack of measures taken to protect the structure of the web page. Exploiting this vulnerability allows a remote attacker to perform a cross-site scripting attack...
Unauthorized Access Vulnerability in Communication Module CLM920_NC5 of Shanghai Haige Information Technology Co.
Ltd. is engaged in the research, development, production and operation of 3G/3.75G/4G/NB communication module, which is a communication module company with a patch production factory. An unauthorized access vulnerability exists in communication module CLM920NC5 of Shanghai Haige Information...
Siemens SIRIUS Motor Starter M200D Communication Module PROFINET
Binary data 764685.prm...
Rockwell Automation/Allen-Bradley 1794 FLEX I/O Communication Module Detection
Binary data 193.prm...
Hitachi Communication Module Detection
Binary data 757808.prm...
Siemens Climatix BACnet/IP Communication Module < 10.34 XSS
Binary data 720066.prm...
Hitachi Communication Module Detection
Binary data 757809.prm...
Rockwell Automation 1756-RIO ControlLogix Remote I/O Communication Module
Binary data 752986.prm...
Covert Backdoor Transmission Method: GhostTunnel
GhostTunnel is a covert backdoor transmission method that can be used in an isolated environment. It can attack the target through the HID device only to release the payload agent, then the HID device can be removed after the payload is released. GhostTunnel use 802.11 Probe Request Frames and...
The vulnerability of the microprogramming software of the TIM 1531 IRC communication module, related to authentication errors, allows a perpetrator to gain access to the device with administrator privileges.
The vulnerability of the microprogramming software for the TIM 1531 IRC communication module is related to the improper implementation of the authentication algorithm. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain access to the device with administrator...
Siemens TIM 1531 IRC Security Bypass Vulnerability
The Siemens TIM 1531 IRC is a communication module from Siemens that handles data transfer using the Siemens remote control protocol SINAUT ST7. A security vulnerability exists in the Siemens TIM 1531 IRC prior to version 1.1. A remote attacker could use this vulnerability to perform administrati...
Siemens CP 243 Communication Module HTTP Detection
Binary data 700225.prm...
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Memory Read Vulnerability
The Medfusion 4000 Wireless Syringe Infusion Pump is a syringe infusion pump deployed in healthcare and public health for delivering small doses of medication in acute care settings. A memory read vulnerability exists in the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, where a...
Siemens Climatix BACnet/IP Communication Module Multiple Vulnerabilities (SSA-142512)
Siemens Climatix BACnet/IP Communication Module is prone to multiple vulnerabilities. SPDX-FileCopyrightText: 2015 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...
PT-2015-6445
Name of the Vulnerable Software and Affected Versions Siemens Climatix BACnet/IP communication module versions prior to 10.34 Description A cross-site scripting XSS issue exists, allowing remote attackers to inject arbitrary web script or HTML via a crafted URL. This affects the integrated web...
CVE-2015-4174: Improper Neutralization of Input During Web Page Generation
Cross-site scripting XSS vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...
CVE-2015-3459: Undefined Security Weakness
The communication module on the Hospira LifeCare PCA Infusion System before 7.0 does not require authentication for root TELNET sessions, which allows remote attackers to modify the pump configuration via unspecified commands...