34 matches found
EUVD-2020-27241
Malware in sbrugna...
EUVD-2020-27240
Malware in sbrugna...
EUVD-2018-9665
Malware in sbrugna...
EUVD-2024-49921
Malicious code in bioql PyPI...
EUVD-2023-40603
Malicious code in bioql PyPI...
CVE-2020-6087
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious...
CVE-2020-6086
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious...
CVE-2024-9409
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network...
CVE-2024-9409
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network...
CVE-2024-9409
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network...
CVE-2024-9409
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network...
CVE-2024-9409
CVE-2024-9409 affects Schneider Electric PowerLogic PM5300 series with Ethernet. Description confirms an Uncontrolled Resource Consumption vulnerability (CWE-400) that can cause devices to become unresponsive and lose communication when a large amount of IGMP packets is observed on the network. C...
Schneider Electric多款产品 资源管理错误漏洞
The Schneider Electric PowerLogic PM5320, among others, is a power and energy meter from Schneider Electric France. A resource management error vulnerability exists in various Schneider Electric products that stems from the presence of uncontrolled resource consumption, which could result in an...
Error: XDDS:F26A2921 Studio Cannot Contact DDC
After a failed upgrade for StoreFront 2.5 and while repairing StoreFront, Studio lost communication to the DDC. Details Error Id: XDDS:F26A2921 Exception: Citrix.Console.Common.CitrixAggregateException One or more parallel operations failed at Citrix.Console.Common.CitrixParallel.InternalForEachT...
CVE-2023-36659
An issue was discovered in OPSWAT MetaDefender KIOSK 4.6.1.9996. Long inputs were not properly processed, which allows remote attackers to cause a denial of service loss of communication...
CVE-2023-36659
An issue was discovered in OPSWAT MetaDefender KIOSK 4.6.1.9996. Long inputs were not properly processed, which allows remote attackers to cause a denial of service loss of communication...
CVE-2022-26026
CVE-2022-26026 describes a denial-of-service in Open Automation Software OAS Platform V16.00.0112, specifically in the OAS Engine SecureConfigValues functionality. A specially crafted unauthenticated network message can trigger a change to the TCP configuration port, potentially causing the platf...
Open Automation Software OAS Platform 访问控制错误漏洞
Open Automation Software OAS Platform is an industrial Internet of Things IoT suite from Open Automation Software, Inc. A denial-of-service vulnerability exists in Open Automation Software OAS Platform, which can be exploited by attackers to cause a loss of communication with the help of speciall...
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules Missing Authentication For Critical Function (CVE-2018-17924)
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller...
Rockwell Automation 1794-AENT Flex I/O Series B Buffer Copy Without Checking Size of Input (CVE-2020-6086)
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen- Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious...