Lucene search
+L

166280 matches found

Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•22 views

PT-2026-80946

Multiple DrayTek VigorAP models contain a buffer overflow vulnerability in the apautotest function. The vulnerability is caused by missing length checks during memory copy operations involving the CMD6 field. A remote attacker can trigger this vulnerability via crafted input, causing a denial of...

7.2CVSS6.2AI score0.00683EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•20 views

PT-2026-80942

Multiple DrayTek VigorAP models contain a command injection vulnerability in the mesh start speed test function. The vulnerability is caused by insufficient sanitization of the meshdevice index and meshdevice ip fields before command execution. A remote attacker can trigger this vulnerability via...

7.2CVSS6.1AI score0.02265EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•28 views

PT-2026-80952

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the webBackupAction function. The vulnerability is caused by insufficient filtering of the option, key, pw encode, pathN, and valueN fields before command execution. A remote attacker can trigger this vulnerability v...

7.2CVSS6.2AI score0.02265EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•18 views

PT-2026-80981

AzuraCast exposes the Liquidsoap custom configuration fields through an endpoint that does not require the permission guarding them. The backend config property in backend/src/Entity/Station.php is annotated with GROUP GENERAL, and PUT /api/station/station id/profile/edit in...

8.8CVSS5.4AI score0.00411EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•1 views

CVE-2026-76836: Improper Control of Generation of Code

AzuraCast exposes the Liquidsoap custom configuration fields through an endpoint that does not require the permission guarding them. The backendconfig property in backend/src/Entity/Station.php is annotated with GROUPGENERAL, and PUT /api/station/stationid/profile/edit in...

8.8CVSS6AI score0.00411EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•2 views

CVE-2026-71910: Improper Neutralization of Special Elements used in an OS Command

Multiple DrayTek VigorAP models contain a command injection vulnerability in the apautotest function. The vulnerability is caused by insufficient validation of the CMD0, CMD3, and CMD6 fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS6.5AI score0.02265EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•21 views

PT-2026-80964

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setTime function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

7.2CVSS6.1AI score0.02265EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•20 views

PT-2026-80969

Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the webBackupAction function. The vulnerability is caused by repeated string concatenation of the pathN, valueN, key, and option fields into fixed-size stack buffers without total length checks. A remote attacker can...

7.2CVSS6.2AI score0.00683EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•20 views

PT-2026-80971

Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the poe schedule profile function. The vulnerability is caused by repeated concatenation of the start date, start time, duration time, how often, weekdays, monthly date, and cycle duration fields into small fixed-size...

7.2CVSS6.2AI score0.00683EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•22 views

PT-2026-80962

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the fdftDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execu...

7.2CVSS6.2AI score0.02265EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•20 views

PT-2026-80965

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the tftp upgrade function. The vulnerability is caused by insufficient filtering before the filename field is concatenated into a command. A remote attacker can trigger this vulnerability via crafted input to execute...

7.2CVSS6.1AI score0.01783EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•23 views

PT-2026-80968

Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the pingtrace function. The vulnerability is caused by missing length checks when the host, count, and interval fields are concatenated into a fixed-size buffer. A remote attacker can trigger this vulnerability via...

7.2CVSS6.2AI score0.00683EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•24 views

PT-2026-80002

Valkey is a distributed key-value database. Prior to 7.2.14, 8.0.10, 8.1.9, 9.0.5, and 9.1.1, Valkey's RESTORE command accepts a malformed RDB stream payload that assigns one Pending Entry List NACK to multiple consumers during stream consumer-group deserialization, causing a use-after-free when...

8.8CVSS5.9AI score0.0117EPSS
SaveExploits0References14
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•1 views

CVE-2026-71916: Improper Neutralization of Special Elements used in an OS Command

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the commandTable function. The vulnerability is caused by incomplete filtering of dangerous characters such as backticks, newline characters, and single quotes in the parameter field. A remote attacker can trigger th...

8.6CVSS6.4AI score0.01783EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•1 views

CVE-2026-71923: Improper Neutralization of Special Elements used in an OS Command

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the authset function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS6.5AI score0.02265EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•1 views

CVE-2026-71931: Improper Neutralization of Special Elements used in an OS Command

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the tftpupgrade function. The vulnerability is caused by insufficient filtering before the filename field is concatenated into a command. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS6.5AI score0.01783EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•0 views

CVE-2026-9254: Improper Neutralization of Special Elements used in an OS Command

An unauthenticated OS command injection vulnerability exists in the parental control functionality of Archer BE800 V1, BE3600 V1, and AX75 V1 due to improper filtering and neutralization of special characters in certain parameters. A LAN-based attacker can inject arbitrary commands and execute th...

8.7CVSS6.3AI score0.03055EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/24 12:00 a.m.•0 views

CVE-2026-71928: Improper Neutralization of Special Elements used in an OS Command

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the fdftDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execu...

8.6CVSS6.5AI score0.02265EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/08/24 12:00 a.m.•24 views

PT-2026-79818

Name of the Vulnerable Software and Affected Versions 4MOSAn GCB Doctor affected versions not specified Description An OS Command Injection issue exists where unauthenticated remote attackers can execute arbitrary system commands on the server. This is possible through a parameter in an unremoved...

9.8CVSS5.8AI score0.02043EPSS
SaveExploits0References6
Vulnrichment
Vulnrichment
•added 2026/08/24 12:00 a.m.•8 views

CVE-2026-30512

A local privilege escalation vulnerability exists in the Restricted Access Kiosk Mode implementation of Scheidt & Bachmann entervo HMI prior to V2 R5 P0 M5. The vulnerability affects the external PDF viewer functionality used to display the application manual and its interaction with the underlyi...

5.9AI score0.00168EPSS
SaveExploits0References2
Rows per page
Query Builder