Lucene search
+L

94673 matches found

Positive Technologies
Positive Technologies
•added 2026/09/09 12:00 a.m.•24 views

PT-2026-89105

CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause privilege escalation to root and unauthorized execution of administrative functions when an authenticated user with SSH enabled interacts with the operating syste...

8.7CVSS7.7AI score0.00666EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/09/09 12:00 a.m.•21 views

PT-2026-89074

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit...

5.5CVSS5.8AI score0.02285EPSS
SaveExploits0References2
VulnCheck KEV
VulnCheck KEV
•added 2026/09/09 12:00 a.m.•15 views

VulnCheck KEV: CVE-2024-2851

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely...

9.8CVSS6.7AI score0.04009EPSS
SaveIn wildExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•10 views

CVE-2026-77120: Improper Neutralization of Special Elements used in an OS Command

CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause privilege escalation to root and unauthorized execution of administrative functions when an authenticated user with SSH enabled interacts with the operating syste...

8.7CVSS7.7AI score0.00666EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•9 views

CVE-2026-70425: Improper Neutralization of Special Elements used in an OS Command

Dell PowerScale OneFS, Versions 9.5.0.0 through 9.7.1.0, Versions 9.8.0.0 through 9.10.1.0, and Versions 9.11.0.0 through 9.14.0.1, contain a command injection vulnerability. An admin privileged local attacker could potentially exploit this vulnerability, leading to elevation of privileges to roo...

6.7CVSS6.1AI score0.00535EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•7 views

CVE-2026-79741: Improper Neutralization of Special Elements used in a Command

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in a Command 'Command Injection' vulnerability. An unauthenticated attacker with remote access could potentially exploit this...

5.3CVSS6AI score0.03526EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•9 views

CVE-2026-78493: Improper Neutralization of Special Elements used in a Command

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit...

7.8CVSS5.9AI score0.02491EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•5 views

CVE-2026-78482: Improper Neutralization of Special Elements used in an SQL Command

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit...

7.8CVSS5.9AI score0.02491EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•8 views

CVE-2026-78484: Improper Neutralization of Special Elements used in a Command

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit...

7.8CVSS5.9AI score0.02491EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•10 views

CVE-2026-87911: Improper Neutralization of Special Elements used in an OS Command

An OS command injection weakness in the read-only enforcement of the SQL validation component in Amazon awslabs postgres-mcp-server before 1.1.7 might allow an unauthenticated actor to execute operating system commands on the host of a self-managed PostgreSQL server by placing a crafted COPY ... ...

9.6CVSS6.2AI score0.01738EPSS
SaveExploits0References3
Packet Storm
Packet Storm
•added 2026/09/09 12:00 a.m.•43 views

...[ More ]

Tozed ZLT X300 5G CPE Router firmware version 6.01.3 contains an OS command injection vulnerability in the TR-069/CWMP client daemon netcwmpd. The IPPingDiagnostics Host parameter is passed unsanitized into sprintf, which constructs a shell command executed via systembyroot as root. An attacker...

5.9AI score
SaveExploits0
Positive Technologies
Positive Technologies
•added 2026/09/09 12:00 a.m.•22 views

PT-2026-89061

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in a Command 'Command Injection' vulnerability. An unauthenticated attacker with remote access could potentially exploit this...

5.3CVSS5.9AI score0.03526EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/09/09 12:00 a.m.•19 views

PT-2026-89081

Dell PowerScale OneFS, Versions 9.5.0.0 through 9.7.1.0, Versions 9.8.0.0 through 9.10.1.0, and Versions 9.11.0.0 through 9.14.0.1, contain a command injection vulnerability. An admin privileged local attacker could potentially exploit this vulnerability, leading to elevation of privileges to roo...

6.7CVSS6AI score0.00535EPSS
SaveExploits0References1
Arista
Arista
•added 2026/09/09 12:00 a.m.•66 views

Security Advisory 0165

Security Advisory 0165 . CSAF PDF Date: September 9, 2026 Revision | Date | Changes ---|---|--- 1.0 | September 9, 2026 | Initial release 1.1 | September 22, 2026 | CSAF JSON file added The CVE-ID tracking this issue: CVE-2026-73454 CVSSv3.1 Base Score: 8.1...

8.6CVSS6AI score0.00392EPSS
SaveExploits0Affected Software1
Arista
Arista
•added 2026/09/09 12:00 a.m.•39 views

Security Advisory 0162

Security Advisory 0162 . CSAF PDF Date: September 9, 2026 Revision | Date | Changes ---|---|--- 1.0 | September 9, 2026 | Initial release 1.1 | September 22, 2026 | CSAF JSON file added The CVE-ID tracking this issue: CVE-2026-73447 CVSSv3.1 Base Score: 9.1...

9.4CVSS6.6AI score0.00705EPSS
SaveExploits0Affected Software1
Positive Technologies
Positive Technologies
•added 2026/09/09 12:00 a.m.•15 views

PT-2026-89062

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in a Command 'Command Injection' vulnerability. An unauthenticated attacker with remote access could potentially exploit this...

5.3CVSS5.9AI score0.04725EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•10 views

CVE-2026-79947: Improper Neutralization of Special Elements used in an SQL Command

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit...

5.5CVSS5.9AI score0.01803EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/09 12:00 a.m.•6 views

CVE-2026-79941: Improper Neutralization of Special Elements used in a Command

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in a Command 'Command Injection' vulnerability. An unauthenticated attacker with remote access could potentially exploit this...

9.8CVSS6AI score0.04725EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/09/09 12:00 a.m.•20 views

PT-2026-89078

Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A high privileged attacker with remote acces...

7.2CVSS5.9AI score0.00931EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2026/09/09 12:00 a.m.•46 views

Palo Alto Networks PAN-OS 10.2.x / 11.1.x / 11.2.x / 12.1.x / 12.2.x Vulnerability

The version of Palo Alto Networks PAN-OS running on the remote host is a vulnerable version of 10.2.x, 11.1.x, 11.2.x, 12.1.x, or 12.2.x. It is, therefore, affected by a vulnerability. A command injection vulnerability in Palo Alto Networks PAN-OS software enables an authenticated administrator t...

7.1CVSS6.9AI score0.00509EPSS
SaveExploits0References2
Rows per page
Query Builder