Lucene search
K

14 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2017-4277

Malware in sbrugna...

6.1CVSS6.6AI score0.00219EPSS
Exploits2References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2017-4278

Malware in sbrugna...

10CVSS9.4AI score0.0314EPSS
Exploits2References4
Positive Technologies
Positive Technologies
added 2020/06/02 12:0 a.m.1 views

PT-2020-13663 · Open Source Matters · Joomla!

Name of the Vulnerable Software and Affected Versions: Joomla! versions prior to 3.9.19 Description: The issue arises from incorrect input validation of the module tag option in com modules, allowing for cross-site scripting XSS. Recommendations: For versions prior to 3.9.19, update to version...

6.1CVSS6.3AI score0.00226EPSS
Exploits0References6
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.12 views

Siemens SICAM RTUs SM-2556 COM Modules Code Injection

Binary data 720107.prm...

10CVSS7.3AI score0.0314EPSS
Exploits2References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.11 views

Siemens SICAM RTUs SM-2556 COM Modules Authentication Bypass

Binary data 720105.prm...

5.3CVSS7.3AI score0.00298EPSS
Exploits2References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.10 views

Siemens SICAM RTUs SM-2556 COM Modules XSS

Binary data 720106.prm...

6.1CVSS7.3AI score0.00219EPSS
Exploits2References2
Prion
Prion
added 2017/11/15 8:29 a.m.13 views

Design/Logic Flaw

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the...

5CVSS6.2AI score0.00298EPSS
Exploits2References2Affected Software1
OSV
OSV
added 2017/11/15 8:29 a.m.0 views

CVE-2017-12739

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected devic...

9.8CVSS6.2AI score0.0314EPSS
Exploits2References2
Prion
Prion
added 2017/11/15 8:29 a.m.14 views

Code injection

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected devic...

10CVSS9.8AI score0.0314EPSS
Exploits2References2Affected Software1
Cvelist
Cvelist
added 2017/11/15 8:0 a.m.10 views

CVE-2017-12737

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the...

5.3AI score0.00298EPSS
Exploits2References2
CVE
CVE
added 2017/11/15 8:0 a.m.55 views

CVE-2017-12738

CVE-2017-12738 concerns Cross-Site Scripting in the integrated web server of Siemens SICAM RTUs SM-2556 COM Modules (firmware ENOS00, ERAC00, ETA2, ETLS00, MODi00, DNPi00). The issue arises from XSS in the web interface, potentially gatecrashed by a malicious link, with user interaction required....

6.1CVSS5.9AI score0.00219EPSS
Exploits2References2Affected Software1
CVE
CVE
added 2017/11/15 8:0 a.m.63 views

CVE-2017-12739

Siemens SICAM RTUs SM-2556 COM Modules with firmware ENOS00, ERAC00, ETA2, ETLS00, MODi00, DNPi00 expose a web server on port 80 that could allow unauthenticated remote attackers to execute arbitrary code (CVE-2017-12739). The issue is tied to code injection via the integrated web server; remedia...

10CVSS9.7AI score0.0314EPSS
Exploits2References2Affected Software1
CVE
CVE
added 2017/11/15 8:0 a.m.50 views

CVE-2017-12737

The CVE-2017-12737 entry applies to Siemens SICAM RTUs SM-2556 COM Modules (firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, DNPi00). The vulnerability arises from a missing authentication for a critical function: the integrated web server (port 80) could allow unauthenticated remote acces...

5.3CVSS5.2AI score0.00298EPSS
Exploits2References2Affected Software1
0day.today
0day.today
added 2017/11/15 12:0 a.m.72 views

Siemens SICAM RTUs SM-2556 COM Modules XSS / Bypass / Code Execution Vulnerabilities

Siemens SICAM RTUs SM-2556 COM modules firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00 suffer from authentication bypass, code execution, and cross site scripting vulnerabilities. ======================================================================= title: Authentication...

10CVSS6.7AI score0.0314EPSS
Exploits2
Rows per page
Query Builder