Lucene search
+L

19 matches found

Vulnrichment
Vulnrichment
•added 2026/07/07 5:31 p.m.•15 views

CVE-2026-48956 Joomla! Core - [20260710] - Incorrect Access Control in com_modules

An improper access check allows users to display a list of modules in the frontend...

6.4CVSS5.8AI score0.00274EPSS
SaveExploits0References1
EUVD
EUVD
•added 2025/10/07 12:30 a.m.•13 views

EUVD-2017-4278

Malware in sbrugna...

10CVSS8.1AI score0.05646EPSS
SaveExploits2References4
EUVD
EUVD
•added 2025/10/07 12:30 a.m.•12 views

EUVD-2017-4277

Malware in sbrugna...

6.1CVSS6.9AI score0.00873EPSS
SaveExploits2References4
attackerkb
attackerkb
•added 2021/01/12 4:00 p.m.•10 views

CVE-2021-23123

An issue was discovered in Joomla! 3.0.0 through 3.9.23. The lack of ACL checks in the orderPosition endpoint of commodules leak names of unpublished and/or inaccessible modules...

5.3CVSS6AI score0.0118EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
•added 2020/06/02 12:00 a.m.•7 views

PT-2020-13663 · Open Source Matters · Joomla!

Name of the Vulnerable Software and Affected Versions: Joomla! versions prior to 3.9.19 Description: The issue arises from incorrect input validation of the module tag option in com modules, allowing for cross-site scripting XSS. Recommendations: For versions prior to 3.9.19, update to version...

6.1CVSS6.3AI score0.00986EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•18 views

Siemens SICAM RTUs SM-2556 COM Modules XSS

Binary data 720106.prm...

6.1CVSS7.3AI score0.00873EPSS
SaveExploits2References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•17 views

Siemens SICAM RTUs SM-2556 COM Modules Code Injection

Binary data 720107.prm...

10CVSS7.3AI score0.05646EPSS
SaveExploits2References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•17 views

Siemens SICAM RTUs SM-2556 COM Modules Authentication Bypass

Binary data 720105.prm...

5.3CVSS7.3AI score0.01743EPSS
SaveExploits2References2
Prion
Prion
•added 2017/11/15 8:29 a.m.•23 views

Code injection

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected devic...

10CVSS9.8AI score0.05646EPSS
SaveExploits2References2Affected Software1
Prion
Prion
•added 2017/11/15 8:29 a.m.•27 views

Design/Logic Flaw

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the...

5CVSS6.2AI score0.01743EPSS
SaveExploits2References2Affected Software1
OSV
OSV
•added 2017/11/15 8:29 a.m.•11 views

CVE-2017-12739

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected devic...

9.8CVSS6.2AI score0.05646EPSS
SaveExploits2References2
CVE
CVE
•added 2017/11/15 8:00 a.m.•79 views

CVE-2017-12738

CVE-2017-12738 concerns Cross-Site Scripting in the integrated web server of Siemens SICAM RTUs SM-2556 COM Modules (firmware ENOS00, ERAC00, ETA2, ETLS00, MODi00, DNPi00). The issue arises from XSS in the web interface, potentially gatecrashed by a malicious link, with user interaction required....

6.1CVSS6.8AI score0.00873EPSS
SaveExploits2References2Affected Software1
CVE
CVE
•added 2017/11/15 8:00 a.m.•73 views

CVE-2017-12737

The CVE-2017-12737 entry applies to Siemens SICAM RTUs SM-2556 COM Modules (firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, DNPi00). The vulnerability arises from a missing authentication for a critical function: the integrated web server (port 80) could allow unauthenticated remote acces...

5.3CVSS6.5AI score0.01743EPSS
SaveExploits2References2Affected Software1
CVE
CVE
•added 2017/11/15 8:00 a.m.•90 views

CVE-2017-12739

Siemens SICAM RTUs SM-2556 COM Modules with firmware ENOS00, ERAC00, ETA2, ETLS00, MODi00, DNPi00 expose a web server on port 80 that could allow unauthenticated remote attackers to execute arbitrary code (CVE-2017-12739). The issue is tied to code injection via the integrated web server; remedia...

10CVSS8.7AI score0.05646EPSS
SaveExploits2References2Affected Software1
Cvelist
Cvelist
•added 2017/11/15 8:00 a.m.•34 views

CVE-2017-12737

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the...

5.3AI score0.01743EPSS
SaveExploits2References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/11/15 12:00 a.m.•1 views

CVE-2017-12738: Improper Neutralization of Input During Web Page Generation

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked into clicking...

6.1CVSS6.8AI score0.00873EPSS
SaveExploits2References2
zdt
zdt
•added 2017/11/15 12:00 a.m.•103 views

Siemens SICAM RTUs SM-2556 COM Modules XSS / Bypass / Code Execution Vulnerabilities

Siemens SICAM RTUs SM-2556 COM modules firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00 suffer from authentication bypass, code execution, and cross site scripting vulnerabilities. ======================================================================= title: Authentication...

10CVSS6.7AI score0.05646EPSS
SaveExploits2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/11/15 12:00 a.m.•3 views

CVE-2017-12737: Exposure of Sensitive Information to an Unauthorized Actor

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the...

5.3CVSS6.5AI score0.01743EPSS
SaveExploits2References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/11/15 12:00 a.m.•2 views

CVE-2017-12739: Initialization of a Resource with an Insecure Default

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server port 80/tcp of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected devic...

10CVSS8.7AI score0.05646EPSS
SaveExploits2References2
Rows per page
Query Builder