AstraLinux
AstraLinux
added 2026/05/20 5:53 a.m.5 views

Astra Linux – Vulnerability in libmodbus

A issue was discovered in libmodbus before versions 3.0.7 and 3.1.x, prior to 3.1.5. There is a buffer overflow vulnerability in the MODBUSFCWRITEMULTIPLECOILS case, also known as VD-1302...

9.1CVSS7.9AI score0.01981EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2026/01/07 9:33 a.m.8 views

CVE-2019-7225

The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags MODBUS coils mapping to the HMI. These credentials are the idal123...

8.8CVSS7.1AI score0.02895EPSS
Exploits1References1
Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.29 views

ABB PB610 Panel Builder 600 Use of Hard-Coded Credentials (CVE-2019-7225)

The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool Panel Builder 600 to flash a new interface and Tags MODBUS coils mapping to the HMI. These credentials are the idal123...

8.8CVSS7.3AI score0.02895EPSS
Exploits1References5
Pen Test Partners Blog
Pen Test Partners Blog
added 2020/06/01 6:55 a.m.46 views

Introduction to PLCs and Ladder Logic

Introduction We do a lot of client work with ICS, IIoT, and SCADA. We've been to various power plants, factories, electricity substations and they all use the same technology in the form of a PLC. A PLC is a Programmable Logic Controller. PLCs are what keep our Critical National Infrastructure...

7.1AI score
Exploits0
OSV
OSV
added 2019/09/17 8:15 p.m.4 views

CVE-2019-6828

A CWE-248: Uncaught Exception vulnerability exists Modicon M580 firmware version prior to V2.90, Modicon M340 firmware version prior to V3.10, Modicon Premium all versions, and Modicon Quantum all versions, which could cause a possible denial of service when reading specific coils and registers i...

7.5CVSS7.1AI score0.01526EPSS
Exploits0References1
Talos
Talos
added 2019/08/13 12:0 a.m.66 views

Schneider Electric Modicon M580 UMAS Read System Coils and Registers Denial of Service Vulnerability

Summary An exploitable denial of service vulnerability exists in the UMAS Read System Coils and Registers functionality of the Schneider Electric Modicon M580 Programmable Automation Controller firmware version SV2.80. A specially crafted UMAS command can cause the device to enter a non-recoverab...

7.8CVSS7.8AI score0.01526EPSS
Exploits0
OSV
OSV
added 2019/07/31 11:15 p.m.2 views

DEBIAN-CVE-2019-14462

An issue was discovered in libmodbus before 3.0.7 and 3.1.x before 3.1.5. There is an out-of-bounds read for the MODBUSFCWRITEMULTIPLECOILS case, aka VD-1302...

9.1CVSS7.7AI score0.01981EPSS
Exploits0References1
OSV
OSV
added 2019/07/31 11:15 p.m.2 views

UBUNTU-CVE-2019-14462

An issue was discovered in libmodbus before 3.0.7 and 3.1.x before 3.1.5. There is an out-of-bounds read for the MODBUSFCWRITEMULTIPLECOILS case, aka VD-1302...

9.8CVSS5.8AI score0.01981EPSS
Exploits0References6
Cvelist
Cvelist
added 2019/06/27 4:38 p.m.29 views

CVE-2019-7225

The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags MODBUS coils mapping to the HMI. These credentials are the idal123...

8.9AI score0.02895EPSS
Exploits1References4
Talos
Talos
added 2019/06/10 12:0 a.m.309 views

Schneider Electric Modicon M580 UMAS write system coils and holding registers denial-of-service vulnerability

Summary An exploitable denial-of-service vulnerability exists in the UMAS write system coils and holding registers functionality of the Schneider Electric Modicon M580 Programmable Automation Controller, firmware version SV2.70. A specially crafted UMAS command can cause the device to enter a...

7.5CVSS7.7AI score0.01582EPSS
Exploits1
Metasploit
Metasploit
added 2013/08/30 9:28 p.m.50 views

Modbus Client Utility

This module allows reading and writing data to a PLC using the Modbus protocol. This module is based on the 'modiconstop.rb' Basecamp module from DigitalBond, as well as the mbtget perl script. This module requires Metasploit: https://metasploit.com/download Current source:...

7.2AI score
Exploits0
Check Point Advisories
Check Point Advisories
added 2012/03/19 12:0 a.m.1 views

Non Compliant Scada Modbus Write Multiple Coils Query

...

7AI score
Exploits0
Check Point Advisories
Check Point Advisories
added 2012/03/19 12:0 a.m.0 views

Non Compliant Scada Modbus Write Multiple Coils Response

...

7AI score
Exploits0
Check Point Advisories
Check Point Advisories
added 2012/03/19 12:0 a.m.1 views

Non Compliant Scada Modbus Read Coils Inputs Query

...

7AI score
Exploits0
Check Point Advisories
Check Point Advisories
added 2012/03/19 12:0 a.m.1 views

Non Compliant Scada Modbus Read Coils And Regs Response

...

7AI score
Exploits0
Check Point Advisories
Check Point Advisories
added 2012/03/19 12:0 a.m.3 views

Non Compliant Scada Modbus Write Coils And Rst Comm

...

7AI score
Exploits0
Rows per page