1569 matches found
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on April 3, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-093-01 Hitachi Energy RTU500 Series ICSA-25-093-02 Hitachi Energy TRMTracker...
ABB ACS880 Drives Containing CODESYS RTS
SUMMARY Multiple vulnerabilities regarding the CODESYS Runtime System from CODESYS Group have been publicly reported. CODESYS Runtime System is utilized in the firmware of ABB ACS880 drives to provide IEC 61131-3 programming capabilities. These vulnerabilities could lead to out-of-bound memory...
ABB Low Voltage DC Drives and Power Controllers CODESYS RTS
SUMMARY CODESYS group published several vulnerabilities regarding the CODESYS Runtime System, which is included in the firmware of ABB LV DC drives and power controllers. It is used to implement a selection of features and to provide IEC 611131-3 programming capabilities. These vulnerabilities...
CVE-2025-0694
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access...
CVE-2025-0694
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access...
CVE-2024-41975 CODESYS (Edge) Gateway for Windows insecure default
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs...
CVE-2024-41975 CODESYS (Edge) Gateway for Windows insecure default
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs...
CVE-2025-0694 CODESYS Control V3 removable media path traversal
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access...
CVE-2025-0694
CVE-2025-0694 affects CODESYS Control: insufficient path validation leads to a path traversal flaw that can grant a low-privileged attacker with physical access full filesystem access. The vulnerability is described across multiple feeds (NVD, Red Hat, CVE list) as a removable-media/path traversa...
CVE-2025-0694 CODESYS Control V3 removable media path traversal
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access...
CVE-2025-1468 CODESYS Control V3 - OPC UA Server Authentication bypass
An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy...
CVE-2025-1468 CODESYS Control V3 - OPC UA Server Authentication bypass
An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy...
CVE-2025-1468
CVE-2025-1468 affects CODESYS Control V3 – OPC UA Server. An unauthenticated remote attacker can access sensitive information, including authentication data, when the server uses the non-default Basic128Rsa15 security policy. Impact is information disclosure (CVSS 3.1 base score 7.5; NETWORK, LOW...
CODESYS Runtime Toolkit 安全漏洞
CODESYS Runtime Toolkit is a comprehensive software development kit for programmable controllers from CODESYS, Germany. It is used to convert embedded platforms or industrial PCs into controllers and supports secondary development. A security vulnerability exists in CODESYS Runtime Toolkit versio...
CODESYS Control 路径遍历漏洞
CODESYS Control is a suite of industrial control program programming software from CODESYS, Germany. CODESYS Control suffers from a path traversal vulnerability that stems from insufficient path validation, which could allow a low-privileged attacker to gain full file system access...
CODESYS Edge Gateway 安全漏洞
CODESYS Edge Gateway is an extended CODESYS gateway from CODESYS Germany used to connect CODESYS automation servers to CODESYS PLCs in a local network. A security vulnerability exists in CODESYS Edge Gateway versions prior to 3.5.21.0, which stems from the fact that an unauthenticated remote...
CVE-2022-47383
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution...
CVE-2022-47381
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution...
CVE-2022-47389
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution...
CVE-2022-47385
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution...