+L

83 matches found

osv_cve
osv_cve
•added 2021/05/25 12:15 p.m.•22 views

CVE-2021-30187

CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command...

5.3CVSS5.8AI score0.00268EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2021/05/25 12:00 a.m.•21 views

3S-Smart Software Solutions CODESYS V2 Web-server buffer error vulnerability

3S-Smart Software Solutions CODESYS Control runtime system is an application system from 3S-Smart Software Solutions, Germany. It is used for the conversion of any type of smart device into an IEC 61131-3 controller. An input validation error vulnerability exists in 3S-Smart Software Solutions...

7.5CVSS5.7AI score0.07552EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2021/05/25 12:00 a.m.•12 views

PT-2021-3340 · 3S Smart Software Solutions · Codesys V2 Runtime System

Name of the Vulnerable Software and Affected Versions: CODESYS V2 runtime system SP versions prior to 2.4.7.55 Description: The issue arises from the improper neutralization of special elements used in an OS command, potentially allowing an attacker to impact the confidentiality, integrity, and...

5.3CVSS7.2AI score0.00268EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/05/25 12:00 a.m.•14 views

PT-2021-3346 · 3S Smart Software Solutions · Codesys V2 Runtime System

Name of the Vulnerable Software and Affected Versions: CODESYS V2 runtime system SP versions prior to 2.4.7.55 Description: The issue is a stack-based buffer overflow in the CODESYS V2 runtime system SP. This can be exploited by a remote attacker to impact the confidentiality, integrity, and...

10CVSS7.8AI score0.0127EPSS
SaveExploits0References7
ICS
ICS
•added 2020/09/24 12:00 p.m.•96 views

3S CoDeSys (Update A)

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit/public exploits are available Vendor: 3S-Smart Software Solutions Equipment: CoDeSys Vulnerabilities: Improper Access Control, Relative Path Traversal 2. UPDATE INFORMATION This updated advisory is a...

10CVSS7.6AI score0.05266EPSS
SaveExploits0References31
osv_cve
osv_cve
•added 2020/05/07 1:15 p.m.•20 views

CVE-2020-6081

An exploitable code execution vulnerability exists in the PLCTask functionality of 3S-Smart Software Solutions GmbH CODESYS Runtime 3.5.14.30. A specially crafted network request can cause remote code execution. An attacker can send a malicious packet to trigger this vulnerability...

8.8CVSS7.9AI score0.01757EPSS
SaveExploits1References1
Prion
Prion
•added 2020/05/07 1:15 p.m.•35 views

Design/Logic Flaw

An exploitable code execution vulnerability exists in the PLCTask functionality of 3S-Smart Software Solutions GmbH CODESYS Runtime 3.5.14.30. A specially crafted network request can cause remote code execution. An attacker can send a malicious packet to trigger this vulnerability...

6.5CVSS9AI score0.01757EPSS
SaveExploits1References1Affected Software1
attackerkb
attackerkb
•added 2020/05/07 1:15 p.m.•19 views

CVE-2020-6081

An exploitable code execution vulnerability exists in the PLCTask functionality of 3S-Smart Software Solutions GmbH CODESYS Runtime 3.5.14.30. A specially crafted network request can cause remote code execution. An attacker can send a malicious packet to trigger this vulnerability...

9.9CVSS9.4AI score0.01757EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2020/05/07 12:22 p.m.•49 views

CVE-2020-6081

An exploitable code execution vulnerability exists in the PLCTask functionality of 3S-Smart Software Solutions GmbH CODESYS Runtime 3.5.14.30. A specially crafted network request can cause remote code execution. An attacker can send a malicious packet to trigger this vulnerability...

9.9CVSS9AI score0.01757EPSS
SaveExploits1References1
CVE
CVE
•added 2020/05/07 12:22 p.m.•90 views

CVE-2020-6081

CVE-2020-6081 affects 3S-Smart Software Solutions GmbH CODESYS Runtime 3.5.14.30 (PLC_Task). A crafted network packet enables remote code execution. TALOS detail shows attackers can upload an app via SSH or Codesys port 11740 without cryptographic verification, bypassing authentication, allowing ...

9.9CVSS9AI score0.01757EPSS
SaveExploits1References1Affected Software1
CNVD
CNVD
•added 2020/05/07 12:00 a.m.•28 views

3S-Smart Software Solutions CODESYS Runtime Remote Code Execution Vulnerability

3S-Smart Software Solutions CODESYS Runtime is a controller real-time runtime system based on IEC61131-3 standard programming from 3S-Smart Software Solutions, Germany. The system transforms any embedded or PC-based device into an IEC61131-3 compliant industrial controller. A security vulnerabili...

9.9CVSS7.1AI score0.01757EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/05/07 12:00 a.m.•12 views

CVE-2020-6081: Insufficient Verification of Data Authenticity

An exploitable code execution vulnerability exists in the PLCTask functionality of 3S-Smart Software Solutions GmbH CODESYS Runtime 3.5.14.30. A specially crafted network request can cause remote code execution. An attacker can send a malicious packet to trigger this vulnerability...

9.9CVSS8.8AI score0.01757EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2020/05/07 12:00 a.m.•9 views

PT-2020-18910

Name of the Vulnerable Software and Affected Versions 3S-Smart Software Solutions GmbH CODESYS Runtime version 3.5.14.30 Description An exploitable code execution issue exists in the PLC Task functionality. A specially crafted network request can cause remote code execution. An attacker can send ...

9.9CVSS0.01757EPSS
SaveExploits1References5
osv_cve
osv_cve
•added 2019/12/20 1:15 p.m.•20 views

CVE-2019-19789

3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference...

6.5CVSS6.6AI score0.01218EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/12/20 12:00 a.m.•12 views

CVE-2019-19789: NULL Pointer Dereference

3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference...

6.5CVSS6.5AI score0.01218EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/12/18 12:00 a.m.•10 views

PT-2019-6356

Name of the Vulnerable Software and Affected Versions CODESYS SP Realtime NT versions prior to V2.3.7.28 CODESYS Runtime Toolkit 32 bit full versions prior to V2.4.7.54 CODESYS PLCWinNT versions prior to V2.4.7.54 Description The issue is related to a NULL pointer dereference in the CODESYS SP...

6.8CVSS0.01218EPSS
SaveExploits0References7
CNVD
CNVD
•added 2018/02/26 12:00 a.m.•17 views

WAGO PFC200 Series Incorrect Authentication Vulnerability

The WAGO PFC200 is a bus editable logic controller module from WAGO Germany. An incorrect authentication vulnerability exists in the WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. The vulnerability originates from the CoDeSys Runtime application being available by default over th...

9.8CVSS7.5AI score0.02676EPSS
SaveExploits0References1
Prion
Prion
•added 2018/02/15 10:29 a.m.•32 views

Stack overflow

A Stack-based Buffer Overflow issue was discovered in 3S-Smart CODESYS Web Server. Specifically: all Microsoft Windows also WinCE based CODESYS web servers running stand-alone Version 2.3, or as part of the CODESYS runtime system running prior to Version V1.1.9.19. A crafted request may cause a...

7.5CVSS9.7AI score0.03096EPSS
SaveExploits0References2Affected Software2
Prion
Prion
•added 2018/02/13 9:29 p.m.•29 views

Authentication flaw

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker...

7.5CVSS9.7AI score0.02676EPSS
SaveExploits0References1Affected Software1
osv_cve
osv_cve
•added 2018/02/13 9:29 p.m.•24 views

CVE-2018-5459

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker...

9.8CVSS6AI score0.02676EPSS
SaveExploits0References1
Rows per page