Lucene search
K

8087 matches found

CNVD
CNVD
added 2019/04/02 12:0 a.m.1 views

Grandstream GXV3611IR_HD Trust Management Issues Vulnerability

The Grandstream GXV3611IRHD is a webcam from Grandstream. A security vulnerability exists in Grandstream GXV3611IRHD versions prior to 1.0.3.23. An attacker can exploit the default password or hard-coded passwords, hard-coded certificates, etc. to attack the affected components...

10CVSS6.9AI score0.00393EPSS
Exploits0References1
Tenable Nessus
Tenable Nessus
added 2019/04/01 12:0 a.m.16 views

Cisco Prime Collaboration Provisioning Unauthorized Password Change Denial of Service Vulnerability (cisco-sa-20180801-pcp-dos

According to its self-reported version number, the remote Cisco Prime Collaboration Provisioning server is prior to 12.3. It is, therefore, affected by unauthorized password change denial of service vulnerability which could allow the attacker to cause the affected device to become inoperable,...

6.8CVSS6.6AI score0.00444EPSS
Exploits0References2
0day.today
0day.today
added 2019/03/27 12:0 a.m.62 views

DASAN H660RM Information Disclosure / Hardcoded Key Vulnerability

DASAN H660RM allows for unauthenticated ping access, has a hardcoded key for encryption, and logs sensitive information into /tmp. DASAN H660RM Information Disclosure / Hardcoded Key CVE-2019-9974: diagtool.cgi on DASAN H660RM devices with firmware 1.03-0022 allows spawning ping processes without...

9.1CVSS8.1AI score0.01644EPSS
Exploits4
Prion
Prion
added 2019/03/26 4:29 p.m.16 views

Hardcoded credentials

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password...

4.6CVSS6.9AI score0.00053EPSS
Exploits0References1Affected Software1
NVD
NVD
added 2019/03/26 4:29 p.m.11 views

CVE-2014-5431

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password...

6.8CVSS7.3AI score0.00053EPSS
Exploits0References1
Cvelist
Cvelist
added 2019/03/26 3:37 p.m.7 views

CVE-2014-5431

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password...

6.9AI score0.00053EPSS
Exploits0References1
CVE
CVE
added 2019/03/26 3:37 p.m.50 views

CVE-2014-5431

CVE-2014-5431 affects Baxter SIGMA Spectrum Infusion System 6.05 with Wireless Battery Module 16. The issue is a hard-coded password that grants access to WBM management functions, enabling unauthorized configuration changes (e.g., wireless status and phase-complete audible alarm). The vulnerabil...

6.8CVSS6.5AI score0.00053EPSS
Exploits0References1Affected Software1
Prion
Prion
added 2019/03/26 3:29 p.m.17 views

Hardcoded credentials

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...

5CVSS7AI score0.00248EPSS
Exploits0References1Affected Software1
NVD
NVD
added 2019/03/26 3:29 p.m.10 views

CVE-2014-5434

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...

9.8CVSS9.6AI score0.00248EPSS
Exploits0References1
CVE
CVE
added 2019/03/26 2:59 p.m.39 views

CVE-2014-5434

The CVE-2014-5434 entry concerns Baxter’s SIGMA Spectrum Infusion System: version 6.05 (model 35700BAX) with Wireless Battery Module (WBM) version 16, which contains a default, hard-coded credential used with FTP. The vulnerability allows remote access in some vectors (three vulnerabilities remot...

9.8CVSS9.3AI score0.00248EPSS
Exploits0References1Affected Software1
Packet Storm
Packet Storm
added 2019/03/26 12:0 a.m.86 views

DASAN H660RM Information Disclosure / Hardcoded Key

Hi! CVE-2019-9974: diagtool.cgi on DASAN H660RM devices with firmware 1.03-0022 allows spawning ping processes without any authorization leading to information disclosure and DoS attacks Remote attacker could enumerate hosts on LAN interface sending requests to /cgi-bin/diagtool.cgi with ip...

8.2AI score0.01644EPSS
Exploits4
NVD
NVD
added 2019/03/25 5:29 p.m.10 views

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

10CVSS9.5AI score0.00248EPSS
Exploits0References1
Cvelist
Cvelist
added 2019/03/25 4:2 p.m.8 views

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

9.5AI score0.00248EPSS
Exploits0References1
NVD
NVD
added 2019/03/21 4:1 p.m.8 views

CVE-2019-3495

An issue was discovered on Wifi-soft UniBox controller 0.x through 2.x devices. network/mesh/edit-nds.php is vulnerable to arbitrary file upload, allowing an attacker to upload .php files and execute code on the server with root user privileges. Authentication for accessing this component can be...

9CVSS9AI score0.011EPSS
Exploits1References3
NVD
NVD
added 2019/03/21 4:1 p.m.10 views

CVE-2019-3497

An issue was discovered on Wifi-soft UniBox controller 0.x through 2.x devices. The tools/ping Ping feature of the Diagnostic Tools component is vulnerable to Remote Command Execution, allowing an attacker to execute arbitrary system commands on the server with root user privileges. Authenticatio...

9CVSS9.2AI score0.07366EPSS
Exploits1References3
NVD
NVD
added 2019/03/21 4:1 p.m.5 views

CVE-2019-3496

An issue was discovered on Wifi-soft UniBox controller 3.x devices. The tools/controller/diagnostictoolscontroller Diagnostic Tools Controller is vulnerable to Remote Command Execution, allowing an attacker to execute arbitrary system commands on the server with root user privileges. Authenticati...

9CVSS9.2AI score0.07366EPSS
Exploits1References3
OSV
OSV
added 2019/03/21 4:0 p.m.1 views

CVE-2018-20219

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

8.1CVSS5.8AI score0.42901EPSS
Exploits4References3
NVD
NVD
added 2019/03/21 4:0 p.m.14 views

CVE-2018-20219

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

9.3CVSS8.3AI score0.42901EPSS
Exploits4References3
Prion
Prion
added 2019/03/21 4:0 p.m.16 views

Authentication flaw

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

9.3CVSS8.7AI score0.42901EPSS
Exploits4References3Affected Software3
Cvelist
Cvelist
added 2019/03/18 5:40 p.m.9 views

CVE-2019-3497

An issue was discovered on Wifi-soft UniBox controller 0.x through 2.x devices. The tools/ping Ping feature of the Diagnostic Tools component is vulnerable to Remote Command Execution, allowing an attacker to execute arbitrary system commands on the server with root user privileges. Authenticatio...

9.2AI score0.07366EPSS
Exploits1References3
Rows per page