10 matches found
CVE-2024-41984
A vulnerability has been identified in SmartClient modules Opcenter QL Home SC All versions = V13.2 = V13.2 = V13.2 V2506. The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications...
EUVD-2024-54869
Malicious code in bioql PyPI...
EUVD-2024-54865
Malicious code in bioql PyPI...
CVE-2024-41980
A vulnerability has been identified in SmartClient modules Opcenter QL Home SC All versions = V13.2 = V13.2 = V13.2 V2506. The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive...
CVE-2024-41983
A vulnerability has been identified in SmartClient modules Opcenter QL Home SC All versions = V13.2 = V13.2 = V13.2 V2506. The affected application displays SQL statement in the error messages encountered during the generation of reports using Cockpit tool...
CVE-2024-41979
A vulnerability has been identified in SmartClient modules Opcenter QL Home SC All versions = V13.2 = V13.2 = V13.2 V2506. The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete acce...
CVE-2024-41979
A vulnerability has been identified in SmartClient modules Opcenter QL Home SC All versions = V13.2 = V13.2 = V13.2 V2506. The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete acce...
CVE-2024-41980
The CVE-2024-41980 issue affects SmartClient Opcenter QL Home, SOA Audit, and SOA Cockpit. Affected SmartClient components do not encrypt LDAP interface communications by default, enabling an authenticated attacker to access sensitive information. Affected versions are 13.2 through 2505 (inclusiv...
CVE-2024-41979
A vulnerability has been identified in SmartClient modules Opcenter QL Home SC All versions = V13.2 = V13.2 = V13.2 V2506. The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete acce...
Siemens Opcenter Quality
SUMMARY The Opcenter Quality is affected by multiple vulnerabilities in the SmartClient modules Opcenter QL Home SC, SOA Audit and SOA Cockpit. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general...