Lucene search
K

6 matches found

RedhatCVE
RedhatCVE
added 2026/04/16 7:22 p.m.1 views

CVE-2026-6196

A vulnerability was detected in Tenda F456 1.0.0.5. This affects the function fromexeCommand of the file /goform/exeCommand. Performing a manipulation of the argument cmdinput results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and...

9CVSS6.3AI score0.0002EPSS
Exploits0References1
ATTACKERKB
ATTACKERKB
added 2026/04/13 5:45 p.m.0 views

CVE-2026-6196

A vulnerability was detected in Tenda F456 1.0.0.5. This affects the function fromexeCommand of the file /goform/exeCommand. Performing a manipulation of the argument cmdinput results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and...

9CVSS6.3AI score0.0002EPSS
Exploits0References5Affected Software1
Vulnrichment
Vulnrichment
added 2026/03/09 4:32 a.m.0 views

CVE-2026-3802 Tenda i3 exeCommand formexeCommand stack-based overflow

A vulnerability was determined in Tenda i3 1.0.0.62204. Affected by this issue is the function formexeCommand of the file /goform/exeCommand. Executing a manipulation of the argument cmdinput can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been...

9CVSS6.3AI score0.00106EPSS
Exploits1References5
Positive Technologies
Positive Technologies
added 2025/12/29 12:0 a.m.3 views

PT-2025-53719

Name of the Vulnerable Software and Affected Versions Tenda M3 version 1.0.0.134903 Description A stack-based buffer overflow exists in Tenda M3. The issue is due to manipulation of the cmdinput argument within an unknown function of the /goform/exeCommand file. This allows for remote attacks. Th...

9CVSS7AI score0.00185EPSS
Exploits1References9
CNVD
CNVD
added 2024/07/23 12:0 a.m.7 views

Tenda O3 formexeCommand function buffer overflow vulnerability

Tenda O3 is an outdoor wireless bridge from Tenda, China. A security vulnerability exists in Tenda O3, which stems from the manipulation of the parameter cmdinput in the function formexeCommand can lead to a stack-based buffer overflow, which could allow remote launch of an attack. No detailed...

9CVSS7.1AI score0.00779EPSS
Exploits1References1
OSV
OSV
added 2024/04/17 12:15 p.m.0 views

CVE-2024-3909

A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...

9.8CVSS6.4AI score
Exploits0References4
Rows per page
Query Builder