8976 matches found
CVE-2019-9101
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they...
CVE-2019-9101
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they...
Design/Logic Flaw
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configuration file contains parameters that represent passwords in cleartext...
Code injection
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they...
CVE-2019-9104
CVE-2019-9104 affects Moxa MGate MB3170/MB3270 (before 4.1), MB3180 (before 2.1), MB3280/MB3480 (before 3.1), and MB3660 (before 2.3). The issue is that the device configuration file stores passwords in cleartext, enabling potential information disclosure. The threat is elevated by network exposu...
CVE-2019-9101
CVE-2019-9101 affects Moxa MGate MB3xxx Series Protocol Gateways (MB3170/MB3270 up to firmware 4.1, MB3280/MB3480 up to 3.1, MB3660 up to 2.3, MB3180 up to 2.1). The issue causes sensitive information to be transmitted to the web server in cleartext, which may allow an attacker observing traffic ...
CVE-2019-9104
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configuration file contains parameters that represent passwords in cleartext...
CVE-2019-9101
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they...
CVE-2019-5107
A cleartext transmission vulnerability exists in the network communication functionality of WAGO e!Cockpit version 1.5.1.1. An attacker with access to network traffic can easily intercept, interpret, and manipulate data coming from, or destined for e!Cockpit. This includes passwords,...
CVE-2019-5107
CVE-2019-5107 affects WAGO e!Cockpit 1.5.1.1. TALOS details a network cleartext transmission vulnerability where data, including passwords and configurations, can be intercepted, interpreted, and manipulated over unencrypted network traffic between GatewayService and PLC devices. CVSSv3 score is ...
Critical Bugs in Rockwell, Johnson Controls ICS Gear
Security vulnerabilities that require very little skill to exploit have been discovered in industrial control systems ICS gear from Rockwell Automation and Johnson Controls, which anchor a flurry of bug disclosures impacting critical infrastructure. First, a set of critical vulnerabilities in...
Design/Logic Flaw
A vulnerability has been identified in Control Center Server CCS All versions V1.5.0, SiNVR/SiVMS Video Server All versions V5.0.0. The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server CCS maintain log files that store login credentials in cleartext. In configurations...
CVE-2019-19291
CVE-2019-19291 affects Siemens CCS and SiNVR/SiVMS Video Server. The FTP services store login credentials in cleartext in log files, enabling authenticated remote attackers to extract credentials when FTP is enabled. Affected: CCS before v1.5.0 and Video Server before v5.0.0. Mitigation: upgrade ...
CVE-2019-19291
A vulnerability has been identified in Control Center Server CCS All versions V1.5.0, SiNVR/SiVMS Video Server All versions V5.0.0. The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server CCS maintain log files that store login credentials in cleartext. In configurations...
PT-2020-2443 · Siemens · Control Center Server +1
Name of the Vulnerable Software and Affected Versions: Control Center Server CCS versions prior to V1.5.0 SiNVR/SiVMS Video Server versions prior to V5.0.0 Description: A vulnerability has been identified where the FTP services of the SiVMS/SiNVR Video Server and the Control Center Server CCS...
Rockwell Automation MicroLogix Controllers and RSLogix 500 Software
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: MicroLogix 1400 Controllers, MicroLogix 1100 Controllers, and RSLogix 500 Software Vulnerabilities: Use of Hard-coded Cryptographic Key, Use of a Broken or Risky...
WAGO e!Cockpit network communication cleartext transmission vulnerability
Summary A cleartext transmission vulnerability exists in the network communication functionality of WAGO e!Cockpit, version 1.5.1.1. An attacker with access to network traffic can easily intercept, interpret, and manipulate data coming from, or destined for e!Cockpit. This includes passwords,...
Helium: Cleartext Transmission of Sensitive Information Leads to administrator access
The weakness of the program is Cleartext Transmission of Sensitive Information through URL Leads to administrator access. This program is having one feature like we can add users like administrator and read-only, these are roles, into organizations. Here I get the administrator role at same...
CVE-2020-9477
An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker...
CVE-2020-9477
An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker...