9025 matches found
CVE-2023-0864
The CVE-2023-0864 issue affects ABB Terra AC wallbox variants (UL40/80A, UL32A, CE MID, CE Juno CE, CE PTB, Symbiosis, JP) with cleartext transmission of configuration/sensitive data. Root cause: plaintext transmission over BLE, enabling a nearby attacker to access configuration data. Affected ve...
CVE-2023-0864 Configuration data is exchanged in plaintext and could be available to a nearby attacker if present during configuration or usage of the device via Bluetooth Low Energy (BLE).
Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox UL40/80A, ABB Terra AC wallbox UL32A, ABB Terra AC wallbox CE Terra AC MID, ABB Terra AC wallbox CE Terra AC Juno CE, ABB Terra AC wallbox CE Terra AC PTB, ABB Terra AC wallbox CE Symbiosis, ABB Terra AC wallbox...
CVE-2023-0864 Configuration data is exchanged in plaintext and could be available to a nearby attacker if present during configuration or usage of the device via Bluetooth Low Energy (BLE).
Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox UL40/80A, ABB Terra AC wallbox UL32A, ABB Terra AC wallbox CE Terra AC MID, ABB Terra AC wallbox CE Terra AC Juno CE, ABB Terra AC wallbox CE Terra AC PTB, ABB Terra AC wallbox CE Symbiosis, ABB Terra AC wallbox...
PT-2023-3091 · Abb · Abb Terra Ac Wallbox
Name of the Vulnerable Software and Affected Versions: ABB Terra AC wallbox UL40/80A versions 1.0;0 through 1.5.5 ABB Terra AC wallbox UL32A versions 1.0;0 through 1.6.5 ABB Terra AC wallbox CE Terra AC MID versions 1.0;0 through 1.6.5 ABB Terra AC wallbox CE Terra AC Juno CE versions 1.0;0 throu...
Snap One OvrC Cloud (Update A)
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Snap One Equipment: OvrC Cloud, OvrC Pro Devices Vulnerabilities: Improper Input Validation, Observable Response Discrepancy, Improper Access Control, Cleartext Transmission of Sensitive Information,...
SUSE CVE-2023-32784
In KeePass 2.x before 2.54, it is possible to recover the cleartext master password from a memory dump, even when a workspace is locked or no longer running. The memory dump can be a KeePass process dump, swap file pagefile.sys, hibernation file hiberfil.sys, or RAM dump of the entire system. The...
CVE-2023-31408
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attac...
CVE-2023-31408
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attac...
CVE-2023-31408
The CVE-2023-31408 entry affects the SICK FTMg AIR FLOW SENSOR (partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526). Root cause: cleartext storage of sensitive information in the browser’s local storage, enabling potential exposure through cross-site scripting. Impact state...
CVE-2023-31408
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attac...
CVE-2023-31408
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attac...
CVE-2023-32784
In KeePass 2.x before 2.54, it is possible to recover the cleartext master password from a memory dump, even when a workspace is locked or no longer running. The memory dump can be a KeePass process dump, swap file pagefile.sys, hibernation file hiberfil.sys, or RAM dump of the entire system. The...
PT-2023-23302
Name of the Vulnerable Software and Affected Versions SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 Description The issue allows a remote attacker to potentially steal user credentials stored in the user's browser's local storage via...
CVE-2023-32784
In KeePass 2.x before 2.54, it is possible to recover the cleartext master password from a memory dump, even when a workspace is locked or no longer running. The memory dump can be a KeePass process dump, swap file pagefile.sys, hibernation file hiberfil.sys, or RAM dump of the entire system. The...
SICK FTMg 安全漏洞
SICK FTMg is a flow sensor from SICK. A security vulnerability exists in the SICK FTMg AIR FLOW SENSOR that stems from the presence of sensitive information stored in clear text, allowing a remote attacker to potentially steal user credentials stored locally in a user's browser via a cross-site...
CVE-2023-32784
In KeePass 2.x before 2.54, it is possible to recover the cleartext master password from a memory dump, even when a workspace is locked or no longer running. The memory dump can be a KeePass process dump, swap file pagefile.sys, hibernation file hiberfil.sys, or RAM dump of the entire system. The...
CVE-2022-47880
An Information disclosure vulnerability in /be/rpc.php in Jedox GmbH Jedox 2020.2.5 allow remote, authenticated users with permissions to modify database connections to disclose a connections' cleartext password via the 'test connection' function...
Information disclosure
An Information disclosure vulnerability in /be/rpc.php in Jedox GmbH Jedox 2020.2.5 allow remote, authenticated users with permissions to modify database connections to disclose a connections' cleartext password via the 'test connection' function...
CVE-2022-47880
An Information disclosure vulnerability in /be/rpc.php in Jedox GmbH Jedox 2020.2.5 allow remote, authenticated users with permissions to modify database connections to disclose a connections' cleartext password via the 'test connection' function...
CVE-2022-47880
The CVE-2022-47880 vulnerability affects Jedox implementations exposing /be/rpc.php (test connection) and allows remote, authenticated users with permission to modify database connections to disclose cleartext passwords. The issue is demonstrated in Jedox versions such as 2020.2.5 and is also cit...