Lucene search
+L

11 matches found

EUVD
EUVD
added 2025/10/03 8:7 p.m.19 views

EUVD-2024-40004

Malicious code in bioql PyPI...

7.5CVSS6.6AI score0.00176EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 4:10 a.m.10 views

CVE-2023-39086

ASUS RT-AC66U B1 3.0.0.4.28651665 was discovered to transmit sensitive information in cleartext...

7.5CVSS6.8AI score0.00313EPSS
Exploits0
CVE
CVE
added 2025/05/01 12:0 a.m.76 views

CVE-2025-46633

CVE-2025-46633 affects the Tenda RX2 Pro web management portal (version 16.03.30.14). The root cause is the cleartext transmission of the symmetric AES key in responses after successful authentication, with a fixed IV (EU5H62G9ICGRNI43). This enables an attacker with network access to decrypt tra...

8.2CVSS6.5AI score0.00229EPSS
Exploits1References2Affected Software1
Vulnrichment
Vulnrichment
added 2025/01/28 8:0 p.m.11 views

CVE-2025-0784 Intelbras InControl Registered User usuario cleartext transmission

A vulnerability has been found in Intelbras InControl up to 2.21.58 and classified as problematic. This vulnerability affects unknown code of the file /v1/usuario/ of the component Registered User Handler. The manipulation leads to cleartext transmission of sensitive information. The attack can b...

6.3CVSS4.3AI score0.00472EPSS
Exploits1References4
ICS
ICS
added 2024/09/10 6:0 a.m.18 views

BPL Medical Technologies PWS-01-BT and BPL Be Well Android Application

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION : Low attack complexity/public exploits are available Vendor : BPL Medical Technologies Equipment : PWS-01-BT, Be Well Android App Vulnerability : Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of...

5.1CVSS7.1AI score0.00658EPSS
Exploits0References10
Positive Technologies
Positive Technologies
added 2023/10/19 12:0 a.m.8 views

PT-2023-27777 · Dexgate · Dexgate

Name of the Vulnerable Software and Affected Versions: DexGate affected versions not specified Description: The affected product is vulnerable to a cleartext transmission of sensitive information vulnerability. This may allow an attacker with access to the network, where clients have access to th...

6.5CVSS6.2AI score0.00241EPSS
Exploits0References6
Tenable Nessus
Tenable Nessus
added 2023/03/01 12:0 a.m.16 views

Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2020-7488)

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. This plugin only works with Tenable.ot. Please visit...

7.5CVSS7.4AI score0.00847EPSS
Exploits0References2
ICS
ICS
added 2022/06/16 12:0 a.m.82 views

AutomationDirect DirectLOGIC with Serial Communication

1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: Low attack complexity Vendor: AutomationDirect Equipment: DirectLOGIC with Serial Communication Vulnerability: Cleartext Transmission of Sensitive Information 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original...

9.1CVSS9.1AI score0.00621EPSS
Exploits0References4
NVD
NVD
added 2022/05/25 9:15 a.m.24 views

CVE-2022-21951

A Cleartext Transmission of Sensitive Information vulnerability in SUSE Rancher, Rancher allows attackers on the network to read and change network data due to missing encryption of data transmitted via the network when a cluster is created from an RKE template with the CNI value overridden This...

6.8CVSS0.00369EPSS
Exploits1References2
ICS
ICS
added 2020/06/18 12:0 a.m.40 views

Baxter Phoenix Hemodialysis Delivery System (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Baxter Equipment: Phoenix Hemodialysis Delivery System Vulnerability: Cleartext Transmission of Sensitive Information 2. UPDATE INFORMATION This updated advisory is a follow-up to the original...

7.5CVSS7.6AI score0.00452EPSS
Exploits0References5
NVD
NVD
added 2018/03/06 9:29 p.m.23 views

CVE-2018-5471

A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may all...

5.9CVSS6.3AI score0.00975EPSS
Exploits0References2
Rows per page
Query Builder