CVE-2021-43329
A SQL injection vulnerability in licenseupdate.php in Mumara Classic through 2.93 allows a remote unauthenticated attacker to execute arbitrary SQL commands via the license parameter...
CVE-2021-21257
Contiki-NG is an open-source, cross-platform operating system for internet of things devices. The RPL-Classic and RPL-Lite implementations in the Contiki-NG operating system versions prior to 4.6 do not validate the address pointer in the RPL source routing header This makes it possible for an...
CVE-2021-32771
Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have...
CVE-2021-36359
OrbiTeam BSCW Classic before 7.4.3 allows exportpdf authenticated remote code execution RCE via XML tag injection because reportlab\platypus\paraparser.py reached via bscw.cgi op=editfolder.EditFolder calls eval on attacker-supplied Python code. This is fixed in 5.0.12, 5.1.10, 5.2.4, 7.3.3, and...
CVE-2021-28135
The Bluetooth Classic implementation in Espressif ESP-IDF 4.4 and earlier does not properly handle the reception of continuous unsolicited LMP responses, allowing attackers in radio range to trigger a denial of service crash in ESP32 by flooding the target device with LMP Feature Response data...
CVE-2021-31787
The Bluetooth Classic implementation on Actions ATS2815 chipsets does not properly handle the reception of continuous unsolicited LMP responses, allowing attackers in radio range to trigger a denial of service and shutdown of a device by flooding the target device with LMPfeaturesres packets...
CVE-2021-39271
OrbiTeam BSCW Classic before 7.4.3 allows authenticated remote code execution RCE during archive extraction via attacker-supplied Python code in the class attribute of a .bscw file. This is fixed in 5.0.12, 5.1.10, 5.2.4, 7.3.3, and 7.4.3...
CVE-2021-25663
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, Nucleus NET All versions, Nucleus ReadyStart V3 All versions V2017.02.4, Nucleus ReadyStart V4 All versions V4.1.0, Nucleus Source Code All versions...
CVE-2021-34145
The Bluetooth Classic implementation in the Cypress WICED BT stack through 2.9.0 for CYW20735B1 devices does not properly handle the reception of LMPmaxslot with an invalid Baseband packet type and LTADDRESS and LTADDR after completion of the LMP setup procedure, allowing attackers in radio range...
CVE-2021-34148
The Bluetooth Classic implementation in the Cypress WICED BT stack through 2.9.0 for CYW20735B1 devices does not properly handle the reception of LMPmaxslot with a greater ACL Length after completion of the LMP setup procedure, allowing attackers in radio range to trigger a denial of service...
CVE-2021-34149
The Bluetooth Classic implementation on the Texas Instruments CC256XCQFN-EM does not properly handle the reception of continuous LMPAURand packets, allowing attackers in radio range to trigger a denial of service deadlock of the device by flooding it with LMPAURand packets after the paging...
CVE-2021-31609
The Bluetooth Classic implementation in Silicon Labs iWRAP 6.3.0 and earlier does not properly handle the reception of an oversized LMP packet greater than 17 bytes, allowing attackers in radio range to trigger a crash in WT32i via a crafted LMP packet...
CVE-2021-31610
The Bluetooth Classic implementation on AB32VG1 devices does not properly handle the reception of continuous unsolicited LMP responses, allowing attackers in radio range to trigger a denial of service either restart or deadlock the device by flooding a device with LMPAUrand data...
CVE-2021-26799
Cross Site Scripting XSS vulnerability in admin/files/edit in Omeka Classic =2.7 allows remote attackers to inject arbitrary web script or HTML...
CVE-2021-43058
An open redirect vulnerability exists in Replicated Classic versions prior to 2.53.1 that could lead to spoofing. To exploit this vulnerability, an attacker could send a link that has a specially crafted URL and convince the user to click the link, redirecting the user to an untrusted site...
CVE-2020-9485
An issue was found in Apache Airflow versions 1.10.10 and below. A stored XSS vulnerability was discovered in the Chart pages of the the "classic" UI...
CVE-2020-11999
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 an...
CVE-2019-7848
Adobe Campaign Classic version 18.10.5-8984 and earlier versions have an Inadequate access control vulnerability. Successful exploitation could lead to Information Disclosure in the context of the current user...