Lucene search
+L

63 matches found

Cvelist
Cvelist
•added 2014/02/26 11:00 a.m.•41 views

CVE-2013-2824

Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...

6.5AI score0.01786EPSS
SaveExploits1References2
CVE
CVE
•added 2014/02/26 11:00 a.m.•71 views

CVE-2013-2824

CVE-2013-2824 affects Schneider Electric StruxureWare SCADA Expert Vijeo Citect (v7.40), Vijeo Citect (v7.20–7.30SP1), CitectSCADA (v7.20–7.30SP1), StruxureWare PowerSCADA Expert (v7.30–7.30SR1), and PowerLogic SCADA (v7.20–7.20SR1). The issue is an exception-handling flaw that allows remote atta...

7.8CVSS6.8AI score0.01786EPSS
SaveExploits1References2Affected Software4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/02/26 12:00 a.m.•5 views

CVE-2013-2824: Undefined Security Weakness

Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...

7.8CVSS5.8AI score0.01786EPSS
SaveExploits1References1
ICS
ICS
•added 2013/09/18 6:00 a.m.•72 views

Schneider Electric CitectSCADA Products Exception Handler Vulnerability (Update A)

OVERVIEW --------- Begin Update A Part 1 of 1 -------- This updated advisory is a follow-up to the original advisory titled ICSA-13-350-01 Schneider Electric SCADA Products Exception Handler Vulnerability that was published February 25, 2014, on the NCCIC/ICS-CERT web site. This advisory was...

7.8CVSS6.5AI score0.01786EPSS
SaveExploits1References10
Cvelist
Cvelist
•added 2013/08/09 11:00 p.m.•36 views

CVE-2013-2796

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...

6.9AI score0.00726EPSS
SaveExploits0References2
CVE
CVE
•added 2013/08/09 11:00 p.m.•86 views

CVE-2013-2796

This entry (CVE-2013-2796) describes an XML External Entity (XXE) vulnerability in Schneider Electric products: Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier. The underlying issue is improper restriction of XML entities, allowing a remote attac...

6.9CVSS7.1AI score0.00726EPSS
SaveExploits0References2Affected Software3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/08/09 12:00 a.m.•4 views

CVE-2013-2796: Undefined Security Weakness

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...

6.9CVSS6AI score0.00726EPSS
SaveExploits0References2
NVD
NVD
•added 2013/04/19 11:44 a.m.•34 views

CVE-2013-3075

Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control...

10CVSS7.8AI score0.10771EPSS
SaveExploits2References1
Prion
Prion
•added 2013/04/19 11:44 a.m.•21 views

Buffer overflow

Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control...

10CVSS8.3AI score0.10771EPSS
SaveExploits2References1Affected Software3
CVE
CVE
•added 2013/04/19 10:00 a.m.•83 views

CVE-2013-3075

CVE-2013-3075 describes a heap-based buffer overflow in Mitsubishi MX Component Version 3 (ActUWzd.dll 1.0.0.1) distributed with CitectFacilities 7.10 and CitectSCADA 7.10r1. The overflow is triggered by oversized input (e.g., WzTitle) to a Mitsubishi MX ActiveX control, allowing remote code exec...

10CVSS8AI score0.10771EPSS
SaveExploits2References1Affected Software3
Packet Storm
Packet Storm
•added 2013/03/25 12:00 a.m.•39 views

Mitsubishi MX Component Active-X Code Execution

//Payload is a windows/bindshell that is spawned on LPORT=5500 shellcode =...

0.3AI score
SaveExploits0
zdt
zdt
•added 2013/03/25 12:00 a.m.•35 views

Mitsubishi MX ActiveX Component v3 (ActUWzd.dll (WzTitle)) - Remote Exploit

Exploit for windows platform in category remote exploits //Payload is a windows/bindshell that is spawned on LPORT=5500 shellcode =...

7.1AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2013/03/25 12:00 a.m.•46 views

Mitsubishi MX ActiveX Component 3 - 'ActUWzd.dll' 'WzTitle' Remote Heap Spray

//Payload is a windows/bindshell that is spawned on LPORT=5500 shellcode =...

10CVSS7.9AI score0.10771EPSS
SaveExploits2
exploitpack
exploitpack
•added 2013/03/25 12:00 a.m.•30 views

Mitsubishi MX ActiveX Component 3 - ActUWzd.dll WzTitle Remote Heap Spray

Mitsubishi MX ActiveX Component 3 - ActUWzd.dll WzTitle Remote Heap Spray //Payload is a windows/bindshell that is spawned on LPORT=5500 shellcode =...

0.3AI score
SaveExploits0
ICS
ICS
•added 2013/02/21 7:00 a.m.•70 views

Mitsubishi Electric Automation MX Component V3 ActiveX Vulnerability

OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-13-091-01 Mitsubishi Electric Automation MX Buffer Overflow Vulnerability that was published April 1, 2013, on the ICS-CERT Web siteICSA-13-091-01, http://ics-cert.us-cert.gov/alerts/ICSA-13-091-01, last accessed May 20, 2013...

10CVSS7.4AI score0.10771EPSS
SaveExploits2References10
NVD
NVD
•added 2012/09/15 5:55 p.m.•22 views

CVE-2011-5163

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence...

4.6CVSS7.5AI score0.00471EPSS
SaveExploits0References7
Prion
Prion
•added 2012/09/15 5:55 p.m.•21 views

Buffer overflow

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence...

4.6CVSS8.1AI score0.00471EPSS
SaveExploits0References7Affected Software2
Cvelist
Cvelist
•added 2012/09/15 5:00 p.m.•35 views

CVE-2011-5163

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence...

7.5AI score0.00471EPSS
SaveExploits0References7
CVE
CVE
•added 2012/09/15 5:00 p.m.•61 views

CVE-2011-5163

CVE-2011-5163 is a buffer overflow in a third-party component used by the CitectSCADA Batch server and MX4 SCADA Batch module. Affected products include Schneider Electric CitectSCADA up to version 7.20 and Mitsubishi MX4 SCADA up to version 7.20; vulnerability arises from an overly long input st...

4.6CVSS7.8AI score0.00471EPSS
SaveExploits0References7Affected Software2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2012/09/15 12:00 a.m.•5 views

CVE-2011-5163: Improper Restriction of Operations within the Bounds of a Memory Buffer

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence...

4.6CVSS6.5AI score0.00471EPSS
SaveExploits0References2
Rows per page
Query Builder