79 matches found
Xxe
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...
CVE-2013-2796
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...
CVE-2013-2796
This entry (CVE-2013-2796) describes an XML External Entity (XXE) vulnerability in Schneider Electric products: Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier. The underlying issue is improper restriction of XML entities, allowing a remote attac...
CVE-2013-2796: Undefined Security Weakness
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...
Citect SCADA Device Detection
Binary data 6797.prm...
CVE-2013-3075
CVE-2013-3075 describes a heap-based buffer overflow in Mitsubishi MX Component Version 3 (ActUWzd.dll 1.0.0.1) distributed with CitectFacilities 7.10 and CitectSCADA 7.10r1. The overflow is triggered by oversized input (e.g., WzTitle) to a Mitsubishi MX ActiveX control, allowing remote code exec...
Citect SCADA ODBC Overflow Attempt (CVE-2008-2639)
...
CVE-2011-4035
Cross-site scripting XSS vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2011-3330
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...
Buffer overflow
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...
CVE-2011-3330
Buffer overflow in the UnitelWay Windows Device Driver used by Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier allows local users to execute arbi...
CVE-2011-3330
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...
CVE-2011-3330: Improper Restriction of Operations within the Bounds of a Memory Buffer
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...
CitectSCADA/CitectFacilities ODBC - Remote Buffer Overflow (Metasploit)
$Id: citectscadaodbc.rb 11039 2010-11-14 19:03:24Z jduck $ This file is part of the Metasploit Framework and may be subject to redistribution and commercial restrictions. Please see the Metasploit Framework web site for more information on licensing and terms of use...
Citect SCADA ODBC Service Overflow
Added: 03/10/2009 CVE: CVE-2008-2639 BID: 29634 OSVDB: 46105 Background The CitectSCADA and CitectFacilities applications include ODBC server capabilities to provide remote SQL access to a relational database. The ODBC Server component listens on port 20222/tcp by default. Problem A buffer overfl...
Stack overflow
Stack-based buffer overflow in the ODBC server service in Citect CitectSCADA 6 and 7, and CitectFacilities 7, allows remote attackers to execute arbitrary code via a long string in the second application packet in a TCP session on port 20222...
CVE-2008-2639
Stack-based buffer overflow in the ODBC server service in Citect CitectSCADA 6 and 7, and CitectFacilities 7, allows remote attackers to execute arbitrary code via a long string in the second application packet in a TCP session on port 20222...
CVE-2008-2639: Improper Restriction of Operations within the Bounds of a Memory Buffer
Stack-based buffer overflow in the ODBC server service in Citect CitectSCADA 6 and 7, and CitectFacilities 7, allows remote attackers to execute arbitrary code via a long string in the second application packet in a TCP session on port 20222...
Citect CitectSCADA ODBC service buffer overflow
Overview Citect CitectSCADA contains a remotely accessible buffer overflow vulnerability which may allow a remote attacker to execute arbitrary code. Description Citect CitectSCADA is software used for monitoring and control in Supervisory Control And Data Acquisition SCADA systems. A buffer...