CVE-2017-20049
A vulnerability, was found in legacy Axis devices such as P3225 and M3005. This affects an unknown part of the component CGI Script. The manipulation leads to improper privilege management. It is possible to initiate the attack remotely...
CVE-2017-20049: Improper Privilege Management
A vulnerability, was found in legacy Axis devices such as P3225 and M3005. This affects an unknown part of the component CGI Script. The manipulation leads to improper privilege management. It is possible to initiate the attack remotely...
PT-2022-7922 · Axis · Axis Device
Name of the Vulnerable Software and Affected Versions: Axis devices affected versions not specified Description: A vulnerability was found in legacy Axis devices, affecting an unknown part of the component CGI Script. The manipulation leads to improper privilege management, and it is possible to...
CVE-2022-31847: Direct Request
A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request...
Exploit for OS Command Injection in Zyxel Usg_Flex_100W_Firmware
CVE-2022-30525 Zyxel Firewall Remote Command Injection A py...
CVE-2022-33174
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2022-33174
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2022-33175: Incorrect Permission Assignment for Critical Resource
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...
CVE-2022-33174: Incorrect Authorization
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2021-41738
ZeroShell 3.9.5 is affected by a command injection in the /cgi-bin/kerbynet endpoint (IP parameter). An authenticated attacker could execute system commands through this parameter. Affected product/version: ZeroShell 3.9.5. Root cause: command injection via the IP parameter in kerbynet. Impact: p...
CVE-2021-41738: Improper Neutralization of Special Elements used in an OS Command
ZeroShell 3.9.5 has a command injection vulnerability in /cgi-bin/kerbynet IP parameter, which may allow an authenticated attacker to execute system commands...
Barco Control Room Cross-Site Scripting Vulnerability
Barco Control Room is a visualization and collaboration solution from Barco Belgium. Used to build control rooms, a cross-site scripting vulnerability exists in the Barco Control Room Management Suite web application prior to version 3.14. The vulnerability stems from the URL parameter of the...
Telesquare SDT-CW3B1 1.1.0 - OS Command Injection
!/usr/bin/python3 Exploit Title: Telesquare SDT-CW3B1 1.1.0 - OS Command Injection Date: 24th May 2022 Exploit Author: Bryan Leong Vendor Homepage: http://telesquare.co.kr/ CVE : CVE-2021-46422 Authentication Required: No import requests import argparse import sys from xml.etree import ElementTre...
CVE-2022-31486
An authenticated attacker can send a specially crafted route to the “editroute.cgi” binary and have it execute shell commands. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.303...
CVE-2022-26972
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS...
CVE-2022-26972
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS...
PT-2022-18150
Name of the Vulnerable Software and Affected Versions Barco Control Room Management Suite web application version prior to 3.14 Description The issue is related to the exposure of a URL /cgi-bin endpoint in the web application, where URL parameters are not correctly sanitized. This leads to...
CVE-2022-26972: Improper Neutralization of Input During Web Page Generation
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS...
Huawei EulerOS: Security Advisory for ruby (EulerOS-SA-2022-1761)
The remote host is missing an update for the Huawei EulerOS SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
CVE-2022-1669
A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary index.cgi to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Addres...