added 2020/11/19 9:08 p.m.37 views

CVE-2020-7555

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition Def.exe version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF Configuration Group File file is imported to IGSS Definition...

7.8AI score0.02477EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/11/19 9:07 p.m.54 views

CVE-2020-7554

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition Def.exe version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF Configuration Group File file is imported to IGSS Definition...

7.8AI score0.02489EPSS
SaveExploits0References2
CVE
CVE
added 2020/11/19 9:07 p.m.75 views

CVE-2020-7554

Schneider Electric IGSS exposes CVE-2020-7554, a CWE-119 buffer-boundary vulnerability in IGSS Definition (Def.exe) 14.0.0.20247 that can lead to Remote Code Execution when a malicious CGF file is imported. The Red Hat/Red Hat-affiliated and ZDI entries describe a stack-based or related boundary ...

7.8CVSS7.8AI score0.02489EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/11/19 9:07 p.m.43 views

CVE-2020-7553

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition Def.exe version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF Configuration Group File file is imported to IGSS Definition...

7.8AI score0.02436EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/11/19 9:07 p.m.37 views

CVE-2020-7552

A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition Def.exe version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF Configuration Group File file is imported to IGSS Definition...

7.8AI score0.01654EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2020/11/17 12:00 a.m.16 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer overflow vulnerability that stems...

7.8CVSS7.9AI score0.01654EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2020/11/17 12:00 a.m.15 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...

7.8CVSS7.8AI score0.02477EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2020/11/17 12:00 a.m.15 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An out-of-bounds write vulnerability exists in Interactive Graphical SCADA System version...

7.8CVSS7.5AI score0.02477EPSS
SaveExploits0References5
Openbugbounty
Openbugbounty
added 2018/06/25 3:30 a.m.9 views

navcen.uscg.gov XSS vulnerability

Open Bug Bounty ID: OBB-636152 Description| Value ---|--- Affected Website:| navcen.uscg.gov Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...