Lucene search
+L

8214 matches found

Cvelist
Cvelist
added 2018/03/09 11:00 p.m.35 views

CVE-2018-7234

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate...

7.5AI score0.00956EPSS
SaveExploits0References1
CVE
CVE
added 2018/03/09 11:00 p.m.64 views

CVE-2018-7234

Schneider Electric Pelco Sarix Professional devices running firmware older than 3.29.67 are affected by an arbitrary system file download vulnerability. The issue arises from insufficient validation in SSL/TLS handling, enabling an attacker to download arbitrary files via the /cgi-bin/ssldownload...

7.8CVSS7.5AI score0.00956EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2018/02/27 12:00 a.m.10 views

ELinks and Twibright Links Unauthorized Access Vulnerability

ELinks is an open source text-only browser for Linux.Twibright Links is a text-only web browser developed by the Twibright Labs organization that renders graphics and font-size variations with antialiasing and supports JavaScript. A security vulnerability exists in ELinks version 0.12 and Twibrig...

5.9CVSS6.7AI score0.00568EPSS
SaveExploits0References1
CNVD
CNVD
added 2018/02/26 12:00 a.m.5 views

SAP NetWeaver Application Server ABAP Certificate Validation Security Bypass Vulnerability

SAP NetWeaver is the German SAP SAP company's set of service-oriented integrated application platform. The platform provides a development and runtime environment for SAP applications. A security bypass vulnerability exists in SAP NetWeaver Application Server ABAP, which stems from the applicatio...

6.8AI score
SaveExploits0References1
NVD
NVD
added 2018/02/23 5:29 p.m.16 views

CVE-2012-6709

ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...

5.9CVSS5.6AI score0.00568EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2018/02/23 5:29 p.m.6 views

CVE-2012-6709

ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...

5.9CVSS5.5AI score0.00568EPSS
SaveExploits0References3
Prion
Prion
added 2018/02/23 5:29 p.m.18 views

Input validation

ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...

4.3CVSS7AI score0.00568EPSS
SaveExploits0References2Affected Software2
OSV
OSV
added 2018/02/23 5:29 p.m.10 views

CVE-2012-6709

ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...

5.9CVSS6.7AI score
SaveExploits0References4
OSV
OSV
added 2018/02/23 5:29 p.m.8 views

UBUNTU-CVE-2012-6709

ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...

5.9CVSS6.2AI score0.00568EPSS
SaveExploits0References5
Debian CVE
Debian CVE
added 2018/02/23 5:00 p.m.40 views

CVE-2012-6709

ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...

5.9CVSS5.7AI score0.00568EPSS
SaveExploits0
CVE
CVE
added 2018/02/23 5:00 p.m.81 views

CVE-2012-6709

CVE-2012-6709 concerns Elinks 0.12 and Twibright Links 2.3 failing to validate SSL certificates. Connected advisories (EulerOS) and Nessus plugins reference the same issue and identify this as an unpatched vulnerability affecting ELINKS-related packages across multiple Linux distributions. The ro...

5.9CVSS5.5AI score0.00568EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2018/02/15 4:29 p.m.9 views

CVE-2017-17298

Huawei AR120-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR1200 V200R006C10, V200R006C13, V200R007C00, V200R007C01, V200R007C02, V200R008C20, V200R008C30, AR1200-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR150 V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20,...

5.3CVSS6.1AI score0.00765EPSS
SaveExploits0References1
NVD
NVD
added 2018/02/15 10:29 a.m.27 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS6.4AI score0.00673EPSS
SaveExploits0References2
OSV
OSV
added 2018/02/15 10:29 a.m.10 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS5.8AI score0.00673EPSS
SaveExploits0References2
Prion
Prion
added 2018/02/15 10:29 a.m.20 views

Input validation

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

4.3CVSS6.3AI score0.00673EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2018/02/15 10:00 a.m.39 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.7AI score0.00673EPSS
SaveExploits0References2
CVE
CVE
added 2018/02/15 10:00 a.m.65 views

CVE-2017-12721

This CVE concerns the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump and its failure to validate host certificates, enabling potential MITM attacks. Affected firmware versions are 1.1, 1.5, and 1.6. The underlying issue is Improper Certificate Validation, which can allow remote atta...

5.9CVSS5.6AI score0.00673EPSS
SaveExploits0References2Affected Software1
ICS
ICS
added 2018/02/15 12:00 a.m.55 views

Schneider Electric IGSS Mobile

CVSS v3 6.4 ATTENTION: Locally exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: IGSS Mobile Vulnerabilities: Improper Certificate Validation, Plaintext Storage of a Password AFFECTED PRODUCTS Schneider Electric reports that the vulnerabilities affect the following IGS...

6.7CVSS6.4AI score0.01151EPSS
SaveExploits0References4
CNVD
CNVD
added 2018/02/11 12:00 a.m.9 views

Vobot Clock Information Disclosure Vulnerability

The Vobot Clock is a smart bedside alarm clock equipped with Amazon Alexa, Sleep Coach and Daily Routine programs. An information disclosure vulnerability exists in VOBOT CLOCK versions prior to 0.99.30. The vulnerability arises because the Vobot firmware does not validate the certificate of the...

8.1CVSS6.7AI score0.00912EPSS
SaveExploits1References1
CNVD
CNVD
added 2018/02/05 12:00 a.m.14 views

Pulse Secure Desktop Linux clients GUI component man-in-the-middle bypass security vulnerability

Pulse Secure Desktop Linux clients formerly known as Juniper Junos Pulse is Juniper Networks' suite of Linux-based client software for accessing endpoint devices on the Juniper Pulse Secure Gateway.The GUI component also known as PulseUI is one of the graphical user interfaces. The GUI component...

6.5CVSS6.8AI score0.00616EPSS
SaveExploits0References1
Rows per page