8214 matches found
CVE-2018-7234
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate...
CVE-2018-7234
Schneider Electric Pelco Sarix Professional devices running firmware older than 3.29.67 are affected by an arbitrary system file download vulnerability. The issue arises from insufficient validation in SSL/TLS handling, enabling an attacker to download arbitrary files via the /cgi-bin/ssldownload...
ELinks and Twibright Links Unauthorized Access Vulnerability
ELinks is an open source text-only browser for Linux.Twibright Links is a text-only web browser developed by the Twibright Labs organization that renders graphics and font-size variations with antialiasing and supports JavaScript. A security vulnerability exists in ELinks version 0.12 and Twibrig...
SAP NetWeaver Application Server ABAP Certificate Validation Security Bypass Vulnerability
SAP NetWeaver is the German SAP SAP company's set of service-oriented integrated application platform. The platform provides a development and runtime environment for SAP applications. A security bypass vulnerability exists in SAP NetWeaver Application Server ABAP, which stems from the applicatio...
CVE-2012-6709
ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...
CVE-2012-6709
ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...
Input validation
ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...
CVE-2012-6709
ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...
UBUNTU-CVE-2012-6709
ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...
CVE-2012-6709
ELinks 0.12 and Twibright Links 2.3 have Missing SSL Certificate Validation...
CVE-2012-6709
CVE-2012-6709 concerns Elinks 0.12 and Twibright Links 2.3 failing to validate SSL certificates. Connected advisories (EulerOS) and Nessus plugins reference the same issue and identify this as an unpatched vulnerability affecting ELINKS-related packages across multiple Linux distributions. The ro...
CVE-2017-17298
Huawei AR120-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR1200 V200R006C10, V200R006C13, V200R007C00, V200R007C01, V200R007C02, V200R008C20, V200R008C30, AR1200-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR150 V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20,...
CVE-2017-12721
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-12721
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
Input validation
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-12721
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-12721
This CVE concerns the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump and its failure to validate host certificates, enabling potential MITM attacks. Affected firmware versions are 1.1, 1.5, and 1.6. The underlying issue is Improper Certificate Validation, which can allow remote atta...
Schneider Electric IGSS Mobile
CVSS v3 6.4 ATTENTION: Locally exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: IGSS Mobile Vulnerabilities: Improper Certificate Validation, Plaintext Storage of a Password AFFECTED PRODUCTS Schneider Electric reports that the vulnerabilities affect the following IGS...
Vobot Clock Information Disclosure Vulnerability
The Vobot Clock is a smart bedside alarm clock equipped with Amazon Alexa, Sleep Coach and Daily Routine programs. An information disclosure vulnerability exists in VOBOT CLOCK versions prior to 0.99.30. The vulnerability arises because the Vobot firmware does not validate the certificate of the...
Pulse Secure Desktop Linux clients GUI component man-in-the-middle bypass security vulnerability
Pulse Secure Desktop Linux clients formerly known as Juniper Junos Pulse is Juniper Networks' suite of Linux-based client software for accessing endpoint devices on the Juniper Pulse Secure Gateway.The GUI component also known as PulseUI is one of the graphical user interfaces. The GUI component...