Lucene search
K

6 matches found

BDU FSTEC
BDU FSTEC
added 2025/07/24 12:0 a.m.1 views

The vulnerability of the centralized control system for network devices and ports of Advantech iView, related to the lack of measures taken to protect the website structure, allows attackers to carry out XSS attacks.

The vulnerability of the centralized control system for network devices and ports of Advantech iView is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability could allow a malicious actor to carry out XSS attacks remotely...

6.4CVSS5.4AI score0.00126EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2025/07/24 12:0 a.m.2 views

The vulnerability of the centralized control system for network devices and ports of Advantech iView, related to the lack of measures taken to protect the website structure, allows attackers to carry out XSS attacks.

The vulnerability of the centralized control system for network devices and ports of Advantech iView is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability could allow a malicious actor to carry out XSS attacks remotely...

6.4CVSS5.4AI score0.00126EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2023/03/06 12:0 a.m.1 views

The vulnerability of the centralized control system for network devices and ports of Advantech iView arises from the lack of protective measures for the SQL query structure, allowing attackers to disclose protected information.

The vulnerability of the centralized control system for network devices and ports of Advantech iView relates to the lack of measures taken to protect the SQL query structure. Exploiting this vulnerability can allow a malicious actor to disclose the protected information remotely...

6.1CVSS5.6AI score0.00215EPSS
Exploits0References6Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/02/15 12:0 a.m.1 views

The vulnerability of the centralized control system for network devices and ports of Advantech iView arises from the lack of protective measures for the SQL query structure, allowing attackers to disclose protected information.

The vulnerability of the centralized control system for network devices and ports of Advantech iView relates to the lack of measures taken to protect the SQL query structure. Exploiting this vulnerability can allow a malicious actor to disclose the protected information remotely...

5.9CVSS6.8AI score0.00202EPSS
Exploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/02/13 12:0 a.m.1 views

The vulnerability of the centralized control system for network devices and ports of Advantech iView, related to the absence of authentication procedures, allows a perpetrator to execute arbitrary codes or cause service failures.

The vulnerability of the centralized control system for network devices and ports of Advantech iView lies in the absence of authentication procedures. Exploiting this vulnerability allows a malicious actor to execute arbitrary code or trigger service failures remotely...

7.8CVSS7.6AI score0.0033EPSS
Exploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2022/04/07 12:0 a.m.2 views

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a intruder to trigger a service failure.

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, is related to an uncontrolled resource consumption. Exploiting this vulnerability could allow a...

9.4CVSS7.4AI score0.0035EPSS
Exploits0References3
Rows per page
Query Builder