Lucene search
K

8 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-20850

Malware in sbrugna...

5.9CVSS6.8AI score0.0016EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2023/01/25 12:0 a.m.28 views

Siemens SCALANCE X Switches Use of Hard-Coded Cryptographic Key (CVE-2020-28391)

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...

5.9CVSS6.8AI score0.0016EPSS
Exploits0References3
OSV
OSV
added 2021/01/12 9:15 p.m.0 views

CVE-2020-28391

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...

5.9CVSS6.7AI score
Exploits0References2
Prion
Prion
added 2021/01/12 9:15 p.m.23 views

Hardcoded credentials

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...

4.3CVSS5.4AI score0.0016EPSS
Exploits0References2Affected Software54
Positive Technologies
Positive Technologies
added 2021/01/12 12:0 a.m.1 views

PT-2021-2204 · Siemens · C-Plug +2

Name of the Vulnerable Software and Affected Versions: SCALANCE X-200 switch family incl. SIPLUS NET variants versions prior to V5.2.5 SCALANCE X-200IRT switch family incl. SIPLUS NET variants versions prior to V5.5.0 SCALANCE X-200RNA switch family versions prior to V3.2.7 Description: A...

9.4CVSS5.6AI score0.0016EPSS
Exploits0References5
CVE
CVE
added 2021/01/12 12:0 a.m.96 views

CVE-2020-28391

Summary: CVE-2020-28391 affects Siemens SCALANCE X switches (X-200, X-200IRT, X-200RNA; incl. SIPLUS NET variants). Root cause: after factory reset, devices normally generate a new unique key, but when used with C-PLUG they ship a hardcoded private RSA key, enabling a man-in-the-middle and decryp...

5.9CVSS5.4AI score0.0016EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2021/01/12 12:0 a.m.20 views

CVE-2020-28391

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...

5.5AI score0.0016EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.8 views

Siemens XC206 Switch Detection

Binary data 762271.prm...

7.3AI score