222 matches found
CVE-2019-6824
A CWE-119: Buffer Errors vulnerability exists in ProClima all versions prior to version 8.0.0 which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0...
CVE-2019-6824
A CWE-119: Buffer Errors vulnerability exists in ProClima all versions prior to version 8.0.0 which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0...
CVE-2018-7838
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FT...
CVE-2018-7838
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FT...
Buffer overflow
A CWE-119: Buffer Errors vulnerability exists in ProClima all versions prior to version 8.0.0 which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0...
Buffer overflow
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FT...
CVE-2018-7838
CVE-2018-7838 affects Schneider Electric Modicon: Modicon M580 CPU (model BMEP582040) up to version V2.90 and Modicon Ethernet Module BMENOC0301 up to version V2.16. The vulnerability is a CWE-119 buffer error that can cause denial of service on the FTP service when the device processes a FTP CWD...
CVE-2019-6824
A CWE-119: Buffer Errors vulnerability exists in ProClima all versions prior to version 8.0.0 which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0...
CVE-2019-6824
The CVE-2019-6824 entry concerns Schneider Electric ProClima prior to version 8.0.0, where a CWE-119 Buffer Overflow allows an unauthenticated, remote attacker to execute arbitrary code. Connected sources (ICS advisory ICSA-19-295-01 and CNVD-2019-23784) confirm the affected product, vulnerabilit...
CVE-2019-7085
Adobe Acrobat and Reader versions 2019.010.20069 and earlier, 2019.010.20069 and earlier, 2017.011.30113 and earlier version, and 2015.006.30464 and earlier have a buffer errors vulnerability. Successful exploitation could lead to arbitrary code execution...
Code injection
Adobe Acrobat and Reader versions 2019.010.20069 and earlier, 2019.010.20069 and earlier, 2017.011.30113 and earlier version, and 2015.006.30464 and earlier have a buffer errors vulnerability. Successful exploitation could lead to arbitrary code execution...
CVE-2019-7085
CVE-2019-7085 affects Adobe Acrobat and Reader windows/macOS with vulnerable builds including 2019.010.20069 and earlier, 2017.011.30113 and earlier, and 2015.006.30464 and earlier. The Red Hat and Nessus entries corroborate a buffer‑errors vulnerability that could allow arbitrary code execution,...
CVE-2019-7085
Adobe Acrobat and Reader versions 2019.010.20069 and earlier, 2019.010.20069 and earlier, 2017.011.30113 and earlier version, and 2015.006.30464 and earlier have a buffer errors vulnerability. Successful exploitation could lead to arbitrary code execution...
Code injection
Adobe Acrobat and Reader versions 2019.010.20069 and earlier, 2019.010.20069 and earlier, 2017.011.30113 and earlier version, and 2015.006.30464 and earlier have a buffer errors vulnerability. Successful exploitation could lead to arbitrary code execution...
CVE-2019-7020
Adobe Acrobat/Reader on Windows and macOS is affected by CVE-2019-7020 (buffer errors) and related issues described in APSB19-07. The vulnerabilities affect versions prior to 2019.010.20091 (macOS/Windows) and 2015.006.30464–2017.011.30113–2019.010.20069 family, with successful exploitation leadi...
CVE-2019-7020
Adobe Acrobat and Reader versions 2019.010.20069 and earlier, 2019.010.20069 and earlier, 2017.011.30113 and earlier version, and 2015.006.30464 and earlier have a buffer errors vulnerability. Successful exploitation could lead to arbitrary code execution...
CVE-2018-7851
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could caus...
CVE-2018-7851
CVE-2018-7851 involves buffer errors (CWE-119) in Schneider Electric Modicon PLCs. Affected products and firmware histories include: Modicon M580 with firmware prior to v2.50, Modicon M340 prior to v3.01, BMxCRA312xx prior to v2.40, and all firmware versions of Modicon Premium and 140CRA312xxx. T...
CVE-2018-7851
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could caus...
Adobe Acrobat < 2015.006.30475 / 2017.011.30120 / 2019.010.20091 Multiple Vulnerabilities (APSB19-07)
The version of Adobe Acrobat installed on the remote Windows host is a version prior to 2015.006.30475, 2017.011.30120, or 2019.010.20091. It is, therefore, affected by multiple vulnerabilities. - Adobe Acrobat and Reader versions 2019.010.20069 and earlier, 2019.010.20069 and earlier,...