Lucene search
+L

8 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•10 views

EUVD-2020-5721

Malware in sbrugna...

4.6CVSS5AI score0.0038EPSS
SaveExploits1References2
NVD
NVD
•added 2020/08/31 4:15 p.m.•31 views

CVE-2020-13468

Gigadevice GD32F130 devices allow physical attackers to escalate their debug interface permissions via fault injection into inter-IC bonding wires which have insufficient physical protection...

6.8CVSS6.8AI score0.00548EPSS
SaveExploits1References1
NVD
NVD
•added 2020/08/31 4:15 p.m.•27 views

CVE-2020-13470

Gigadevice GD32F103 and GD32F130 devices allow physical attackers to extract data via the probing of easily accessible bonding wires and de-obfuscation of the observed data...

4.6CVSS4.7AI score0.0038EPSS
SaveExploits1References1
Prion
Prion
•added 2020/08/31 4:15 p.m.•27 views

Design/Logic Flaw

Gigadevice GD32F130 devices allow physical attackers to escalate their debug interface permissions via fault injection into inter-IC bonding wires which have insufficient physical protection...

4.6CVSS6.9AI score0.00548EPSS
SaveExploits1References1
CVE
CVE
•added 2020/08/31 3:33 p.m.•54 views

CVE-2020-13470

CVE-2020-13470 affects Gigadevice GD32F103 and GD32F130 microcontrollers. The root cause is physical access enabling probing of bonding wires to de-obfuscate and extract data, with potential high integrity impact and no public remediation details in the provided documents. Monitor for vendor advi...

4.6CVSS4.7AI score0.0038EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2020/08/31 3:33 p.m.•43 views

CVE-2020-13470

Gigadevice GD32F103 and GD32F130 devices allow physical attackers to extract data via the probing of easily accessible bonding wires and de-obfuscation of the observed data...

4.7AI score0.0038EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2020/08/31 3:28 p.m.•43 views

CVE-2020-13468

Gigadevice GD32F130 devices allow physical attackers to escalate their debug interface permissions via fault injection into inter-IC bonding wires which have insufficient physical protection...

6.9AI score0.00548EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/08/31 12:00 a.m.•2 views

CVE-2020-13470: Exposure of Resource to Wrong Sphere

Gigadevice GD32F103 and GD32F130 devices allow physical attackers to extract data via the probing of easily accessible bonding wires and de-obfuscation of the observed data...

4.6CVSS5.8AI score0.0038EPSS
SaveExploits1References2
Rows per page