RedhatCVE
RedhatCVE
added 2026/01/09 9:57 a.m.8 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

2.4CVSS6.8AI score0.00333EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2020-4355

Malware in sbrugna...

2.4CVSS4AI score0.00333EPSS
Exploits0References2
NVD
NVD
added 2020/06/29 2:15 p.m.32 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

2.4CVSS0.00333EPSS
Exploits0References1
Prion
Prion
added 2020/06/29 2:15 p.m.18 views

Hardcoded credentials

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

2.1CVSS5.1AI score0.00333EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:45 p.m.22 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

3.8AI score0.00333EPSS
Exploits0References1
CVE
CVE
added 2020/06/29 1:45 p.m.58 views

CVE-2020-12039

CVE-2020-12039 affects Baxter Sigma Spectrum Infusion System v6.x (35700BAX) and v8.x (35700BAX2); hard-coded passwords entered via keypad grant access to biomedical menus, including device settings, calibration values, and WBM network configuration. This is a local/physical-access issue with pub...

2.4CVSS4.1AI score0.00333EPSS
Exploits0References1Affected Software1
CNVD
CNVD
added 2020/06/19 12:0 a.m.8 views

Baxter Sigma Spectrum Infusion System and Spectrum Infusion System Trust Management Issues Vulnerabilities

The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A trust management issue vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x mod...

2.4CVSS6.8AI score0.00333EPSS
Exploits0References1