Lucene search
+L

65 matches found

EUVD
EUVD
added 2026/08/29 12:31 a.m.12 views

EUVD-2026-67943

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems...

7.1CVSS6.1AI score0.00205EPSS
SaveExploits0References2
NVD
NVD
added 2026/08/28 10:16 p.m.26 views

CVE-2026-81533

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems...

7.1CVSS0.00205EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/08/28 8:28 p.m.40 views

CVE-2026-81533 MongoDB BI Connector ODBC Driver Memory-Safety Issue When Parsing Oversized LIMIT Values

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems...

7.1CVSS0.00205EPSS
SaveExploits0References1
CVE
CVE
added 2026/08/28 8:28 p.m.33 views

CVE-2026-81533

CVE-2026-81533 is a memory-safety vulnerability in the MongoDB BI Connector ODBC Driver . The root cause is the driver copying an unusually long digit sequence following a LIMIT clause into a fixed-size internal buffer without a length check. The issue is only reachable on connections where the d...

7.1CVSS6.1AI score0.00205EPSS
SaveExploits0References1
MongoDB
MongoDB
added 2026/08/28 8:28 p.m.10 views

MongoDB BI Connector ODBC Driver Memory-Safety Issue When Parsing Oversized LIMIT Values

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems...

7.1CVSS6.1AI score0.00205EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2026/08/28 8:22 p.m.23 views

CVE-2026-81520

MongoDB Connector for BI is vulnerable to a denial-of-service condition caused by an unbounded SASL authentication negotiation loop . A network-reachable, unauthenticated client can initiate a SASL-based login exchange and then decline to complete it. Because the negotiation loop had no overall t...

8.7CVSS5.9AI score0.00239EPSS
SaveExploits0References1
NVD
NVD
added 2026/08/28 8:19 p.m.11 views

CVE-2026-77586

In MongoDB Connector for BI, MongoDB object names such as collection, field, and index names are placed into the quoted identifiers of the DDL text returned by SHOW CREATE statements without escaping the identifier delimiter. A user with permission to write to a sampled MongoDB collection can...

8.5CVSS0.00226EPSS
SaveExploits0References1
NVD
NVD
added 2026/08/28 8:19 p.m.12 views

CVE-2026-76798

The MongoSQL Transition Readiness Tool writes query text and user names read from BI Connector log files into its generated HTML report without encoding them for that output context. A user able to issue queries through the BI Connector can influence log content so that markup supplied in a query...

6.9CVSS0.00204EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/08/28 8:18 p.m.40 views

CVE-2026-81518 BI Connector Optional Client Certificate Verification Allows Unauthenticated Connections

When mongosqld is configured with a client certificate authority file, the listener requests a client certificate during the TLS handshake but does not require one, so a client that presents no certificate is still accepted. In deployments that rely on client certificates as the sole means of...

8.7CVSS0.00155EPSS
SaveExploits0References1
MongoDB
MongoDB
added 2026/08/28 8:18 p.m.12 views

BI Connector Optional Client Certificate Verification Allows Unauthenticated Connections

When mongosqld is configured with a client certificate authority file, the listener requests a client certificate during the TLS handshake but does not require one, so a client that presents no certificate is still accepted. In deployments that rely on client certificates as the sole means of...

8.7CVSS5.9AI score0.00155EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2026/08/28 8:18 p.m.23 views

CVE-2026-81518

mongosqld in the MongoDB BI Connector contains a TLS misconfiguration: when a client certificate authority file is configured, the listener requests a client certificate during the TLS handshake but does not require it. In deployments where client certificates serve as the sole authentication mec...

8.7CVSS5.9AI score0.00155EPSS
SaveExploits0References1
CVE
CVE
added 2026/08/28 7:24 p.m.23 views

CVE-2026-76798

The MongoSQL Transition Readiness Tool (part of MongoDB's SQL/BI Connector stack) writes query text and user names from BI Connector log files into its generated HTML reports without encoding them for the HTML output context. An attacker with low privileges who can issue queries through the BI Co...

6.9CVSS5.8AI score0.00204EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/08/28 7:24 p.m.42 views

CVE-2026-76798 MongoSQL Transition Readiness Tool Improper Output Encoding in Generated HTML Reports

The MongoSQL Transition Readiness Tool writes query text and user names read from BI Connector log files into its generated HTML report without encoding them for that output context. A user able to issue queries through the BI Connector can influence log content so that markup supplied in a query...

6.9CVSS0.00204EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/08/28 7:24 p.m.13 views

EUVD-2026-67778

The MongoSQL Transition Readiness Tool writes query text and user names read from BI Connector log files into its generated HTML report without encoding them for that output context. A user able to issue queries through the BI Connector can influence log content so that markup supplied in a query...

6.9CVSS5.8AI score0.00204EPSS
SaveExploits0References1
MongoDB
MongoDB
added 2026/08/28 7:24 p.m.12 views

MongoSQL Transition Readiness Tool Improper Output Encoding in Generated HTML Reports

The MongoSQL Transition Readiness Tool writes query text and user names read from BI Connector log files into its generated HTML report without encoding them for that output context. A user able to issue queries through the BI Connector can influence log content so that markup supplied in a query...

6.9CVSS5.8AI score0.00204EPSS
SaveExploits0References1Affected Software1
MongoDB
MongoDB
added 2026/08/28 7:23 p.m.11 views

MongoDB BI Connector Transition Readiness Report Improper HTML Encoding When Processing Database Metadata

MongoSQL Transition Readiness Tool does not sufficiently encode database metadata before including it in generated HTML. A MongoDB user with write access can introduce crafted metadata that may cause script code to run when another user generates and opens the report, potentially exposing report...

4.8CVSS5.9AI score0.00162EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2026/08/28 7:23 p.m.39 views

CVE-2026-76794 MongoDB BI Connector Transition Readiness Report Improper HTML Encoding When Processing Database Metadata

MongoSQL Transition Readiness Tool does not sufficiently encode database metadata before including it in generated HTML. A MongoDB user with write access can introduce crafted metadata that may cause script code to run when another user generates and opens the report, potentially exposing report...

4.8CVSS0.00162EPSS
SaveExploits0References1
CVE
CVE
added 2026/08/28 7:23 p.m.21 views

CVE-2026-76794

MongoSQL Transition Readiness Tool (part of the MongoDB BI Connector) contains an improper HTML encoding flaw when processing database metadata. A MongoDB user with write access can inject crafted metadata that, when another user generates and opens the Transition Readiness Report, may cause scri...

4.8CVSS5.9AI score0.00162EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2026/08/28 12:00 a.m.19 views

PT-2026-83364

Name of the Vulnerable Software and Affected Versions MongoDB BI Connector ODBC Driver affected versions not specified Description A memory-safety issue exists when the driver processes a SQL statement containing an unusually long sequence of digits following a LIMIT clause. This occurs when the...

7.1CVSS6.1AI score0.00205EPSS
SaveExploits0References3
NVD
NVD
added 2026/08/27 5:19 p.m.10 views

CVE-2026-75159

An unauthenticated client that can reach a MongoDB Connector for BI deployment configured with Kerberos authentication may cause mongosqld to terminate when a crafted authentication exchange encounters a specific GSSAPI error-handling condition. This can interrupt BI Connector availability until...

8.2CVSS0.00264EPSS
SaveExploits0References1
Rows per page
Query Builder